A shear and plantar pressure sensor based on fiber-optic bend loss

被引:54
|
作者
Wang, WC [1 ]
Ledoux, WR
Sangeorzan, BJ
Reinhall, PG
机构
[1] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
[3] Ctr Excellence Limb Loss Prevent & Prosthet Engn, Dept Vet Affairs VA Rehabil Res & Dev, VA Puget Sound Hlth Care Syst, Seattle, WA USA
来源
关键词
anterior/posterior shear; biomechanics; biosensing techniques; diabetes mellitus; foot ulcers; gait; lower-limb complications; plantar pressure; plantar ulcers; ulcer;
D O I
10.1682/JRRD.2004.07.0076
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Lower-limb complications associated with diabetes include the development of plantar ulcers that can lead to infection and subsequent amputation. While we know from force-plate analyses that medial/lateral and anterior/posterior shear components of ground-reaction forces exist, little is known about the actual distribution of these stresses during daily activities or about the role that shear stresses play in causing plantar ulceration. Furthermore, one critical reason why these data have not been obtained previously is the lack of a validated, widely used, commercially available shear sensor, partly because of the various technical issues associated with measuring shear. In this study, we present a novel means of transducing plantar pressure and shear stress with a fiber-optic sensor. The pressure/shear sensor consists of an array of optical fibers lying in perpendicular rows and columns separated by elastomeric pads. We constructed a map of normal and shear stresses based on observed macrobending through the intensity attenuation from the physical deformation of two adjacent perpendicular fibers. Initial results show that this sensor exhibits low noise and responds to applied normal and shear loads with good repeatability.
引用
收藏
页码:315 / 325
页数:11
相关论文
共 50 条
  • [1] Fiber Optic Plantar Pressure/Shear Sensor
    Soetanto, William
    Ngoc Tran Nguyen
    Wang, Wei-Chih
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2011, 2011, 7984
  • [2] Fiber-Optic Bend Sensor Based on Double Cladding Fiber
    Ivanov, Oleg V.
    Chertoriyskiy, Alexey A.
    JOURNAL OF SENSORS, 2015, 2015
  • [3] Miniature fiber-optic pressure sensor
    Zhu, YZ
    Wang, AB
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2005, 17 (02) : 447 - 449
  • [4] Fiber-optic polarization pressure sensor
    Rzhavin, YI
    MEASUREMENT TECHNIQUES, 2002, 45 (07) : 738 - 741
  • [5] Fiber-Optic Polarization Pressure Sensor
    Yu. I. Rzhavin
    Measurement Techniques, 2002, 45 : 738 - 741
  • [6] Temperature and Pressure Sensor Based on Polished Fiber-Optic Microcavity
    Yang, Musen
    Zhu, Yunlong
    An, Ran
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2022, 34 (11) : 607 - 610
  • [7] Smart interpolator for a fiber-optic pressure sensor
    Sun, CS
    Lin, JX
    APPLIED OPTICS, 1997, 36 (21): : 5185 - 5187
  • [8] Smart interpolator for a fiber-optic pressure sensor
    Dalian Univ of Technology, Dalian, China
    Journal of Engineering and Applied Science, 1997, 36 (21): : 5185 - 5187
  • [9] Fiber optic macro-bend based sensor for detection of metal loss
    Li, Weijie
    Ho, Siu Chun Michael
    Luo, Mingzhang
    Huynh, Quyen
    Song, Gangbing
    SMART MATERIALS AND STRUCTURES, 2017, 26 (04)
  • [10] Fiber-optic Temperature Sensor Based on Bending Loss of Thermally Expanded Core Fiber
    Kim, Kwang Taek
    Kang, Ji Hoon
    Cho, Kyu Jung
    Il Moon, Nam
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2010, 21 (01) : 12 - 15