Performance by Design: Supporting Decisions around Indoor Air Quality in Offices

被引:8
|
作者
Snow, Stephen [1 ]
Oakley, Michael [1 ]
Schraefel, M. C. [1 ]
机构
[1] Univ Southampton, Southampton, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
Indoor air quality; CO2; Human-Building Interaction; office; awareness; situated display; design; comfort; POSTOCCUPANCY EVALUATION; VENTILATION RATE; FEEDBACK; CO2; SYMPTOMS; BEHAVIOR; ENERGY;
D O I
10.1145/3322276.3322372
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Poor indoor air quality (IAQ) can affect health and cognitive performance prior to users becoming aware of the declining air quality. Yet office occupants rarely have access to IAQ information upon which to base their ventilation decisions. This paper details the design and deployment of a situated IAQ display as a probe to explore ventilation and building operation practices when IAQ information is made available. Based on deployments in 11 naturally ventilated offices, we present an analysis of how reflection and sense making around IAQ can inform interactions with buildings. We suggest displays that are locally situated, non-disruptive and visualise the effects of poor IAQ with human analogies may hold potential for engaging office occupants with IAQ. We highlight how ambient displays represent a stepping-stone towards more informed interactions which can improve air quality and cognitive performance, and how IAQ feedback may usefully contribute to alternative HCI research agendas such as Human-Building Interaction.
引用
收藏
页码:99 / 111
页数:13
相关论文
共 50 条
  • [1] Indoor Air Quality in offices
    Martin Zorraquino, Juan Vicente
    Mendivil Martinez, Ainhoa
    DYNA, 2008, 83 (05): : 296 - 304
  • [2] Indoor Air Quality Benchmarking for Air Conditioned Offices
    Hui, Pui-shan
    Wong, Ling-tim
    Mui, Kwok-wai
    CLEAN-SOIL AIR WATER, 2009, 37 (06) : 481 - 486
  • [3] Hazard Evaluation of Indoor Air Quality in Bank Offices
    Saidin, Hamidi
    Razak, Azli Abd
    Mohamad, Mohd Faizal
    Ul-Saufie, Ahmad Zia
    Zaki, Sheikh Ahmad
    Othman, Nor'azizi
    BUILDINGS, 2023, 13 (03)
  • [4] Indoor air quality benchmarks of 'Grade A' offices in HongKong
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 685 - 690
  • [5] Sampling strategies of indoor air quality assessment for offices
    Hui, P.
    Wong, L.
    Mui, K.
    FACILITIES, 2007, 25 (5-6) : 179 - +
  • [6] Study of indoor air quality and thermal comfort in offices in Hunan
    Yang, Wei
    Zhang, Guoqiang
    Zhang, Quan
    Journal of Harbin Institute of Technology (New Series), 2007, 14 (SUPPL. 2) : 201 - 203
  • [7] INDOOR AIR QUALITY IN SMALL DOCTOR'S OFFICES IN POLAND
    Gladyszewska-Fiedoruk, Katarzyna
    Krawczyk, Dorota Anna
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 543 - 546
  • [8] An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) : 1362 - 1367
  • [9] Pollutants emission from building materials and their influence on indoor air quality and people performance in offices
    Šeduikyté, Lina
    Bliüdzius, Raimondas
    Journal of Civil Engineering and Management, 2005, 11 (02) : 137 - 144
  • [10] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274