Simultaneous laser-induced fluorescence, coaxial thermal lens spectroscopy and retro-reflected beam interference detection for capillary electrophoresis

被引:7
|
作者
Xiong, Bo [2 ]
Wang, Wei
Miao, Xueyan
Liu, Lijia
Wang, Liping
Zhou, Xiaodong [1 ]
Hu, Jiming [1 ]
机构
[1] Wuhan Univ, Coll Chem & Mol Sci, Inst Analyt Biomed, Key Lab Analyt Chem Biol & Med,Minist Educ, Wuhan 430072, Peoples R China
[2] Cent China Normal Univ, Coll Chem, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary electrophoresis; Coaxial thermal lens spectroscopy; Laser-based fluorescence; Retro-reflected beam interference; Simultaneous detection; FABRY-PEROT INTERFEROMETRY; REFRACTIVE-INDEX DETECTOR; SENSITIVE CHIRAL ANALYSIS; UNIVERSAL DETECTION; BACKSCATTER; CE; ABSORBENCY; SEPARATION; VOLUMES; SYSTEMS;
D O I
10.1016/j.talanta.2011.10.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simultaneous laser-induced fluorescence (LIF), coaxial thermal lens spectroscopy (TLS) and retro-reflected beam interference (RBI) detection for capillary electrophoresis (CE), has been described. In its optical scheme, a diode-pump solid-state (DPSS) laser was employed as the pump laser in both LIF detection and coaxial TLS detection, and a He-Ne laser was utilized as the probe laser in coaxial TLS detection and RBI detection. In addition, RBI signals with and without thermal lens had been theoretically compared to ensure the reliability of the RBI signal. Moreover, the focus length of the key lens has been optimized to improve the performance of the proposed detection. The last but not least, several determinations were taken to evaluate its limit of detection, linear range as well as relative standard deviation, all of which indicate no worse results compared with former reports. LIF and coaxial TLS detection owned high sensitivity, and RBI detection indicated versatile property, based on which the reported detection achieved a sensitive and universal detection for CE. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 50 条
  • [1] Simultaneous coaxial thermal lens spectroscopy and retro-reflected beam interference detection for capillary electrophoresis
    Xiong, Bo
    Miao, Xueyan
    Zhou, Xiaodong
    Deng, Yanzhuo
    Zhou, Ping
    Hu, Jiming
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) : 260 - 266
  • [2] Simultaneous LIF and retro-reflected beam interference detection for CE
    Xiong, Bo
    Wang, Wei
    Miao, Xueyan
    Zhou, Xiaodong
    Deng, Yanzhuo
    Zhou, Ping
    Hu, Jiming
    ELECTROPHORESIS, 2008, 29 (22) : 4482 - 4486
  • [3] Simultaneous determination of doxorubicin, daunorubicin, and idarubicin by capillary electrophoresis with laser-induced fluorescence detection
    Pérez-Ruiz, T
    Martínez-Lozano, C
    Sanz, A
    Bravo, E
    ELECTROPHORESIS, 2001, 22 (01) : 134 - 138
  • [4] Simultaneous laser-induced fluorescence and scattering detection of individual particles separated by capillary electrophoresis
    Andreyev, Dmitry
    Arriaga, Edgar A.
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5474 - 5478
  • [5] LASER-INDUCED FLUORESCENCE AND FLUORESCENCE MICROSCOPY FOR CAPILLARY ELECTROPHORESIS ZONE DETECTION
    HERNANDEZ, L
    ESCALONA, J
    JOSHI, N
    GUZMAN, N
    JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2): : 183 - 196
  • [6] Ultrasensitive capillary electrophoresis of oligoguluronates with laser-induced fluorescence detection
    Lv, ZH
    Sun, Y
    Wang, YH
    Jiang, TF
    Yu, GL
    CHROMATOGRAPHIA, 2005, 61 (11-12) : 615 - 618
  • [7] Analysis of baclofen by capillary electrophoresis with laser-induced fluorescence detection
    Chiang, MT
    Chang, SY
    Whang, CW
    JOURNAL OF CHROMATOGRAPHY A, 2000, 877 (1-2) : 233 - 237
  • [8] Multiplexed microRNA detection by capillary electrophoresis with laser-induced fluorescence
    Jiang, Ruei-Min
    Chang, Yu-Sun
    Chen, Shu-Jen
    Chen, Jian-Hung
    Chen, Hua-Chien
    Chang, Po-Ling
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (18) : 2604 - 2610
  • [9] Analysis of saccharides by capillary electrophoresis with laser-induced fluorescence detection
    Dang, FQ
    Chen, Y
    Guo, Q
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (01) : 80 - 83
  • [10] CAPILLARY ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE DETECTION IN AN UNDERGRADUATE LABORATORY
    MILOFSKY, R
    SMITH, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 194 - CHED