Xenograft Tumor Volume Measurement in Nude Mice: Estimation of 3D Ultrasound Volume Measurements Based on Manual Caliper Measurements

被引:11
|
作者
Baris, Mustafa Mahmut [1 ]
Serinan, Efe [2 ]
Calisir, Meryem [3 ]
Simsek, Kursat [1 ]
Aktas, Safiye [2 ]
Yilmaz, Osman [3 ]
Ozdemir, Sevgi Kilic [4 ]
Secil, Mustafa [1 ]
机构
[1] Dokuz Eylul Univ, Sch Med, Radiol, Izmir, Turkey
[2] Dokuz Eylul Univ, Inst Oncol, Basic Oncol, Izmir, Turkey
[3] Dokuz Eylul Univ, Lab Anim Sci, Izmir, Turkey
[4] Izmir Inst Technol, Chem Engn, Izmir, Turkey
来源
关键词
Tumor volume; nude mice; ultrasonography; 3-D imaging; laboratory animal science; TESTICULAR VOLUME; BONE-MARROW; FORMULAS;
D O I
10.30621/jbachs.2020.902
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives: Volume measurement of subcutaneous xenograft tumors in nude mice models is an important metric to assess tumor growth or response to therapy. Manual calipers are widely used for this purpose. But the measurements with manual calipers may be inaccurate. Contrarily, three-dimensional (3D) ultrasonographic measurements give reliable and accurate tumor volume calculation. We aim to; evaluate the accuracy of common four formulas given in the literature to estimate xenograft tumor volumes based on manual caliper measurements and offer a new coefficient for a better estimation of the tumor volumes. Patients and Methods: Detailed manual diameter measurements of xenograft tumors were in 14 nude mice performed using Vernier caliper. Tumor volumes were calculated using the suggested formulas in the literature based on manual measurements. 3D ultrasound volume measurements were performed on same xenograft tumors using high resolution Vevo 2100 imaging system. To propose a new coefficient; means of ratio between manual and ultrasound volume measurement values were used. Also, data set was divided into two subgroups as tumor volume under 800 mm(3) and over 800 mm(3). New coefficients for each subgroup were defined. Results: Only with prolate ellipsoid formula there was no statistically significant difference between volume measurements with two methods (p=0,24). Our proposed formula (0,45 L*W*H) could estimate tumor volumes as good as prolate ellipsoid formula. Coefficient 0,35 and 0,81 in the same formula were found efficient in the selected subgroups. Conclusion: Using one common coefficient/formula for tumor volume estimation in any tumor size can be inaccurate. Appropriate coefficient should be chosen according to the dataset worked with.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [1] Volume of Preclinical Xenograft Tumors Is More Accurately Assessed by Ultrasound Imaging Than Manual Caliper Measurements
    Ayers, Gregory D.
    McKinley, Eliot T.
    Zhao, Ping
    Fritz, Jordan M.
    Metry, Rebecca E.
    Deal, Brenton C.
    Adlerz, Katrina M.
    Coffey, Robert J.
    Manning, H. Charles
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (06) : 891 - 901
  • [2] Estimation of rat mammary tumor volume using caliper and ultrasonography measurements
    Faustino-Rocha, Ana
    Oliveira, Paula A.
    Pinho-Oliveira, Jacinta
    Teixeira-Guedes, Catarina
    Soares-Maia, Ruben
    da Costa, Rui Gil
    Colaco, Bruno
    Pires, Maria Joao
    Colaco, Jorge
    Ferreira, Rita
    Ginja, Mario
    LAB ANIMAL, 2013, 42 (06) : 217 - 224
  • [3] Estimation of rat mammary tumor volume using caliper and ultrasonography measurements
    Ana Faustino-Rocha
    Paula A. Oliveira
    Jacinta Pinho-Oliveira
    Catarina Teixeira-Guedes
    Ruben Soares-Maia
    Rui Gil da Costa
    Bruno Colaço
    Maria João Pires
    Jorge Colaço
    Rita Ferreira
    Mário Ginja
    Lab Animal, 2013, 42 : 217 - 224
  • [4] Comparison of Tumor Volume Measurements Using MR Images and Caliper Measurements
    Panetta, J.
    Cvetkovic, D.
    Chen, L.
    Ma, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E729 - E730
  • [5] Preclinical Tumor Growth Delay Is More Reliably Derived From Imaging- Based Volume Measurements Than Manual Caliper Measurements
    Shotbolt, M.
    Castro, J.
    Spieler, B.
    Welford, S.
    Mihaylov, I.
    MEDICAL PHYSICS, 2022, 49 (06) : E663 - E663
  • [6] Quantification of carotid plaque volume measurements using 3D ultrasound imaging
    Landry, A
    Spence, JD
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06): : 751 - 762
  • [7] Validation of volume measurements in esophageal pseudotumors using 3D endoluminal ultrasound
    Liu, JB
    Miller, LS
    Chung, CY
    Overton, DA
    Sheera, M
    Forsberg, F
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05): : 735 - 741
  • [8] Volume measurement of large organs with 3D ultrasound
    Treece, GM
    Prager, RW
    Gee, AH
    Berman, L
    MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 : 2 - 13
  • [9] 3D ultrasound measurement of large organ volume
    Treece, G
    Prager, R
    Gee, A
    Berman, L
    MEDICAL IMAGE ANALYSIS, 2001, 5 (01) : 41 - 54
  • [10] Measurement of Carotid Plaque Volume by 3D Ultrasound
    Al-Mohanna, Khalid
    Hossain, Murad
    Khosravi, Abtin
    Zhao, Limin
    Fischell, Jonathan
    Kowalowski, Gregory
    Sikdar, Siddhartha
    Lal, Brajesh K.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 54S - 55S