Arsenic determination in complex mining residues by ICP OES after ultrasonic extraction

被引:36
|
作者
Paula, Jessica F. R. [1 ]
Froes-Silva, Roberta E. S. [2 ]
Ciminelli, Virginia S. T. [1 ]
机构
[1] Univ Fed Minas Gerais, Escola Engn, Dept Engn Met & Mat, Belo Horizonte, MG, Brazil
[2] Univ Fed Ouro Preto, Inst Ciencias Exatas & Biol, Dept Quim, BR-35400000 Ouro Preto, MG, Brazil
关键词
Arsenic extraction; Mining waste; Ultrasound; SPECIATION; BRAZIL; SOIL;
D O I
10.1016/j.microc.2012.03.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The impact caused by mining residue deposits with high amounts of arsenic is a potential environmental problem and motive for investigations. Arsenic is always associated with gold ores and is present in mining areas, probably due to sulfide oxidation and the high pH range where arsenic is soluble. It has been shown that some samples of residues coming from the studied deposits presented arsenic concentrations above 2500 mg kg(-1) The aim of this work is to develop methods for arsenic extraction in mining residues employing ultrasound assistance extraction and analyte determination by hydride generation ICP OES. The analytical method provided analysis precision and a better evaluation of environmental impact of mining residue deposits. Optimal conditions for ultrasound assisted extraction were obtained by evaluation of parameters such as the position of the sample flask inside the ultrasound bath and temperature as a function of the immersion time. These tests identified the ideal position of the sample flask and indicated that the maximum time that the sample could be analyzed without arsenic lost due to increase of the temperature was 180 minutes. With these conditions, an experimental design was developed to obtain the optimal conditions of arsenic extraction, evaluating the type of extraction solution and the sonication time. A 2(2) Central Composite Design (CCD) was employed to evaluate the acid concentration (HCl, HNO3 and H3PO4) and the sonication time (maximum 180 minutes). The quadratic equation of response surface generated by CCD, employing HNO3, indicated that the best condition for arsenic extraction is using an acid concentration of 2.7 mol L-1 and sonication for 136 minutes to give an average concentration of 1847 +/- 17 mg kg(-1). Recovery studies were carried out and the obtained values were close to 100%. Optimal conditions of arsenic extraction were obtained by evaluating the operational parameters of ultrasound bath and the analysis conditions with the experimental design. The method developed contributes significantly to a more precise evaluation of the real environmental impact caused by the mining residues deposit. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:12 / 16
页数:5
相关论文
共 50 条
  • [1] Simultaneous determination of As, Hg, Sb, and Se in mineral fertilizers using ultrasonic extraction and CVG-ICP OES
    Baika, L. M.
    Dos Santos, E. J.
    Herrmann, A. B.
    Grassi, M. T.
    ANALYTICAL METHODS, 2016, 8 (47) : 8362 - 8367
  • [2] Determination of Arsenic by ICP-OES after Cloud Point Extraction with Salt Induced Phase Separation: Application to Gadolinium Based MRI Contrast Agent
    Bunina, Zinaida
    Varchenko, Victoria
    Bryleva, Kateryna
    Chornyi, Vasyl
    Belikov, Konstantin
    CHEMISTRYSELECT, 2022, 7 (29):
  • [3] Determination of REEs in rocks and minerals by solvent extraction and ICP-OES
    Roy, NK
    Roychowdhury, P
    ATOMIC SPECTROSCOPY, 2002, 23 (04) : 125 - 128
  • [4] Direct Determination of Lanthanides in Environmental Samples using Ultrasonic Nebulization and ICP OES
    Bentlin, Fabrina R. S.
    Pozebon, Dirce
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (04) : 627 - 634
  • [5] Determination of micronutrient minerals in coconut milk by ICP OES after ultrasound-assisted extraction procedure
    Santos, Daniele C. M. B.
    Carvalho, Larissa S. B.
    Lima, Daniel C.
    Leao, Danilo J.
    Teixeira, Leonardo S. G.
    Korn, Maria Gracas A.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2014, 34 (01) : 75 - 80
  • [6] Determination of palladium by ultrasonic nebulization coupled to ICP-OES after on-line preconcentration on activated carbon
    Cerutti, S
    Salonia, JA
    Gásquez, JA
    Olsina, RA
    Martinez, LD
    ATOMIC SPECTROSCOPY, 2005, 26 (04) : 145 - 150
  • [7] OPTIMIZATION OF THE SAMPLE PREPARATION PROCEDURE FOR ARSENIC AND ANTIMONY DETERMINATION IN FERROTUNGSTEN BY ICP-OES
    Belozerova, A.
    Mayorova, A.
    Pechischeva, N.
    Boyarnikova, N.
    Shunyaev, K.
    OPTIMIZATION OF THE COMPOSITION, STRUCTURE AND PROPERTIES OF METALS, OXIDES, COMPOSITES, NANO AND AMORPHOUS MATERIALS, 2015, : 88 - 92
  • [8] SIMULTANEOUS DETERMINATION OF METALS AND SULFUR IN CRUDE OIL DISTILLATION RESIDUES BY ICP-OES
    Druzian, Gabriel T.
    Giesbrecht, Cristiano K.
    Rosa, Francisco C.
    Guimaraes, Regina C. L.
    Guarnieri, Ricardo A.
    Mello, Paola A.
    Flores, Erico M. M.
    QUIMICA NOVA, 2016, 39 (09): : 1065 - 1070
  • [9] Evaluation of Metal Ions in Rice Samples: Extraction and Direct Determination by ICP OES
    Oliveira, Andrea
    Baccan, Nivaldo
    Cadore, Solange
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (05) : 838 - 845
  • [10] Determination of Available Boron in Soil by ICP-OES With Boiling Water Extraction
    Zhang Peng-peng
    Hu Meng-ying
    Xu Jin-li
    Chen Wei-ming
    Gu Xue
    Zhang Ling-huo
    Bai Jin-feng
    Zhang Qin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (06) : 1925 - 1929