4-Channel Asynchronous Bio-potential Recording System

被引:0
|
作者
Tang, Wei [1 ]
Huang, Chenxi [1 ]
Kim, Dongsoo [1 ]
Martini, Berin [1 ]
Culurciello, Eugenio [1 ]
机构
[1] Yale Univ, Dept Elect Engn, New Haven, CT 06520 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a 4-channel bio-potential recording system using asynchronous delta analog-to-digital converter. The system is designed to reduce the amount of data in neurophysiological sensors. The circuit includes low-power low-noise amplifiers with asynchronous delta modulators. The analog front end offers a gain of 53dB within bandwidth of 200Hz-20kHz. In this asynchronous data converter, the minimum input-referred delta resolution is 4 mu V. The input-referred rms noise is 2 mu V. The system was fabricated with AMI 0.5 mu m CMOS technology. The chip size is 1.5mm by 1.5mm. The power consumption of the 4-channel system with 3.3V supply is 118.8 mu W in static state and 501.6 mu W with 240kbps data conversion rate. A graphic user interface was developed to monitor the transmitted signal in real time.
引用
收藏
页码:953 / 956
页数:4
相关论文
共 50 条
  • [1] A 4-channel wearable wireless neural recording system
    Chae, Moosung
    Chen, Kuanfu
    Liu, Wentai
    Kim, Jungsuk
    Sivaprakasam, Mohanasankar
    [J]. PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 1760 - 1763
  • [2] ANALYSIS OF MOTOR UNIT POTENTIAL ACTIVITY USING 4-CHANNEL INTRAMUSCULAR RECORDING
    SALMI, T
    NIEMINEN, MK
    [J]. MUSCLE & NERVE, 1990, 13 (10) : 972 - 972
  • [3] Characterization of a Novel Carbonized Foam Electrode for Wearable Bio-potential Recording
    Chen, Hongyu
    Zhao, Yuting
    Mei, Zhenning
    Mei, Yongfeng
    Oetomo, Sidarto Bambang
    Chen, Wei
    [J]. 2018 IEEE 15TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI) AND THE WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2018, : 173 - 176
  • [4] Towards true unipolar bio-potential recording: a preliminary result for ECG
    Gargiulo, Gaetano D.
    McEwan, Alistair L.
    Bifulco, Paolo
    Cesarelli, Mario
    Jin, Craig
    Tapson, Jonathan
    Thiagalingam, Aravinda
    van Schaik, Andre
    [J]. PHYSIOLOGICAL MEASUREMENT, 2013, 34 (01) : N1 - N7
  • [5] Design of 4-channel asynchronous serial communications interface
    Wang Ji
    Liu Zhaoqing
    Zhang Yigang
    [J]. ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 891 - 894
  • [6] A 1.7μW/Channel Time-Division-Multiplexing Analog Front-End for Bio-Potential Recording
    Huang, Yifan
    Liu, Jiayu
    Cheng, Lin
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2024, 71 (08) : 3640 - 3644
  • [7] MATCHING A 4-CHANNEL SYSTEM
    不详
    [J]. AUDIO, 1973, 57 (06): : 4 - 4
  • [8] Implementation of a New Versatile Bio-Potential Measurement System
    Bendib, Hafed-Eddine
    Bahri, Mebarek
    Boumehraz, Mohamed
    Mallem, Ali
    Hamzi, Marwa
    [J]. JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2023, 32 (08)
  • [9] Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems
    Tang, Wei
    Osman, Ahmad
    Kim, Dongsoo
    Goldstein, Brian
    Huang, Chenxi
    Martini, Berin
    Pieribone, Vincent A.
    Culurciello, Eugenio
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2013, 60 (06) : 1407 - 1418
  • [10] Electrical Characterisation of Dry Microneedle Electrodes for Portable Bio-potential Recording Applications
    Pini, Francesco
    O'Mahonl, Conor
    McCarthy, Kevin G.
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON MICROELECTRONIC TEST STRUCTURES (ICMTS), 2012, : 87 - 90