In Vivo Intraocular Lens Thickness Measurement and Power Estimation Using Optical Coherence Tomography

被引:1
|
作者
Barzanouni, Ehsan [1 ,2 ]
Idani, Diba [3 ]
Sharifipour, Farideh [1 ,2 ]
机构
[1] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Res Inst Ophthalmol & Vis Sci, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Sch Med, Dept Ophthalmol, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Med, Tehran, Iran
关键词
Anterior Segment Optical Coherence Tomography; AS-OCT; Intraocular Lens; IOL; IOL Thickness; SCHEIMPFLUG; SYSTEM; OCT;
D O I
10.18502/jovr.v17i3.11572
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To estimate the power of an implanted intraocular lens (IOL) by measuring IOL thickness using anterior segment optical coherence tomography (AS-OCT) and to assess the repeatability of measurements. Methods: Ninety-seven eyes were studied one month after uneventful phacoemulsification within the bag Acrysof SA60AT IOL implantation (range +11 to +35). All eyes had postoperative refraction of +/- 0.5 D of target refraction. AS-OCT was used to measure the central thickness of the IOL. Correlation between labelled IOL power and central IOL thickness as well as the measure of repeatability, for example, intraclass correlation coefficient (ICC), were evaluated. IOL thicknesses were also calculated using a formula and compared with AS-OCT derived measurements. Results: IOL thickness correlated significantly with labelled IOL power (R-2 = 0.985, P < 0.001). The regression equation (IOL Power = [0.04 x IOL thickness in micron] - 7.56) indicates 25 microns of central IOL thickness change per 1D power change. Over the studied range, IOL power could be estimated with a precision of 0.85 +/- 0.02 D (95% confidence interval: 0.83-0.94D). ICC for repeated measurements was 0.999. There was a significant correlation between calculated and measured (AS-OCT) IOL thickness (R-2 = 0.984, P < 0.001). Conclusion: Central IOL thickness measurements with the AS-OCT are highly repeatable and closely correlated with the labelled IOL power, which can predict the IOL power with +/- 0.85 D from the actual power. This method can be helpful in cases of postoperative IOL surprise.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 50 条
  • [1] The Use of Optical Low Coherence Reflectometry in the Measurement of In Vivo Intraocular Lens Power
    Ng, E.
    Weitz, C.
    Cummings, A.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2015, 184 : 452 - 452
  • [2] Optical coherence tomography of intraocular lens glistening
    Tripathy, Koushik
    Sridhar, Uma
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (01) : 138 - +
  • [3] Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry
    Tana-Sanz, Pedro
    Rodriguez-Carrillo, Maria Dolores
    Ruiz-Santos, Maria
    Montes-Mico, Robert
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (12) : 1219 - 1234
  • [4] Intraoperative Optical Coherence Tomography of a Dislocated Intraocular Lens
    Schechet, Sid A.
    Golas, Liliya
    Hariprasad, Seenu M.
    [J]. JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2019, 14 (01) : 116 - 117
  • [5] Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation
    Hirnschall, Nino
    Norrby, Sverker
    Weber, Maria
    Maedel, Sophie
    Amir-Asgari, Sahand
    Findl, Oliver
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (01) : 7 - 10
  • [6] In vivo measurement of the average refractive index of the human crystalline lens using optical coherence tomography
    de Freitas, Carolina
    Ruggeri, Marco
    Manns, Fabrice
    Ho, Arthur
    Parel, Jean-Marie
    [J]. OPTICS LETTERS, 2013, 38 (02) : 85 - 87
  • [7] Automated contact lens measurement using optical coherence tomography
    Davidson, Bryan R.
    Barton, Jennifer K.
    [J]. ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS VII, 2009, 7169
  • [8] Choroidal thickness measurement in children using optical coherence tomography
    Garnier, M. Bidaut
    Schwartz, C.
    Puyraveau, M.
    Montard, M.
    Delbosc, B.
    Saleh, M.
    [J]. ACTA OPHTHALMOLOGICA, 2013, 91
  • [9] CHOROIDAL THICKNESS MEASUREMENT IN CHILDREN USING OPTICAL COHERENCE TOMOGRAPHY
    Bidaut-Garnier, Melanie
    Schwartz, Claire
    Puyraveau, Marc
    Montard, Michel
    Delbosc, Bernard
    Saleh, Maher
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (04): : 768 - 774
  • [10] Contactless measurement of fabric thickness using optical coherence tomography
    Sabuncu, Metin
    Ozdemir, Hakan
    [J]. JOURNAL OF THE TEXTILE INSTITUTE, 2022, 113 (05) : 713 - 717