Experimental study and simulation model of a direct expansion solar assisted heat pump to CO2 for water heating: Inventory, coefficient of performance and total equivalent warming impact

被引:8
|
作者
Humia, Gleberson Marques [1 ]
Duarte, Willian Moreira [1 ,2 ]
Pabon, Juan Jose Garcia [3 ]
Paulino, Tiago de Freitas [4 ]
Machado, Luiz [1 ]
机构
[1] Fed Univ Minas Gerais UFMG, Postgrad Program Mech Engn, Belo Horizonte, MG, Brazil
[2] Univ Ctr Belo Horizonte UniBH, Belo Horizonte, MG, Brazil
[3] Univ Fed Itajuba, Inst Mech Engn, Itajuba, MG, Brazil
[4] Fed Ctr Technol Educ Minas Gerais CEFET MG, Postgrad Program Mech Engn, Belo Horizonte, MG, Brazil
关键词
DX-SAHP; CO2; Void fraction; Inventory; Model; TEWI; EXERGY ANALYSIS; PRESSURE-DROP; SYSTEM; OPTIMIZATION; DESIGN; REFRIGERANTS; EQUATIONS; SELECTION; FRACTION; CHARGE;
D O I
10.1016/j.solener.2021.10.018
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work is a theoretical and experimental study about the refrigerant charge inventory in a CO2 Direct Expansion Solar Assisted Heat Pump to heating residential water. The effects of variation in the irradiation levels were analyzed for 72 experimental points, and a mathematical model was developed to predict the amount of refrigerant in several parts of the system. The conditions of the supercritical fluid and two-phase flow were considered, and eight void fraction correlations were tested. The model revealed that changes in the solar irradiation levels had a significant effect on the mass amount, and the accumulator was responsible for compensating these variations. Nevertheless, in percentage terms, the mass distribution remained practically constant in the heat pump components. The best results for mass prediction were obtained by the correlations of Hughmark and Filimonov, with an average error of 6.38% and 6.88% respectively. Considering a tolerance margin of +/- 2%, Hughmark reached total precision in 19.7% of the predictions against 9.2% achieved by Filimonov, and all the tested correlations had 100% accuracy for a tolerance of +/- 18%. A growth of around 0.3 kW/ m2 in the solar irradiation produced an increase of 30% in Coefficient of Performance (COP) and a reduction of 20% in Total Equivalent Warming Impact (TEWI). Among the conditions analyzed, the best operating point occurred with a COP of 3.67, TEWI of 733 kg CO2-eq and a mass of 589.9 g, with an error of 8.54%.
引用
收藏
页码:278 / 297
页数:20
相关论文
共 50 条
  • [1] Experimental performance analysis of a CO2 direct-expansion solar assisted heat pump water heater
    Duarte, Willian M.
    Rabelo, Sabrina N.
    Paulino, Tiago F.
    Pabon, Juan J. G.
    Machado, Luiz
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 125 : 52 - 63
  • [2] Study on performance of a CO2 heat pump assisted the solar system for heating
    [J]. Yuan, L. (yuanlei_85@hotmail.com), 1600, Science Press (35):
  • [4] Experimental and theoretical study on a solar assisted CO2 heat pump for space heating
    Chen, J. F.
    Dai, Y. J.
    Wang, R. Z.
    [J]. RENEWABLE ENERGY, 2016, 89 : 295 - 304
  • [5] Study on a direct-expansion solar-assisted heat pump water heating system
    Kuang, YH
    Sumathy, K
    Wang, RZ
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (05) : 531 - 548
  • [6] Modeling and experimental analysis of the solar radiation in a CO2 direct-expansion solar-assisted heat pump
    Paulino, Tiago de Freitas
    de Oliveira, Raphael Nunes
    Torres Maia, Antonio Augusto
    Palm, Bjorn
    Machado, Luiz
    [J]. APPLIED THERMAL ENGINEERING, 2019, 148 (160-172) : 160 - 172
  • [7] Experimental performance analysis and optimization of a direct expansion solar assisted heat pump water heater
    Li, Yuwu
    Wang, Ruzhu
    Wang, Taihua
    Wu, Jingyi
    Xu, Yuxiong
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (05): : 464 - 471
  • [8] EXPERIMENTAL INVESTIGATION OF THE PERFORMANCE OF A DIRECT EXPANSION SOLAR ASSISTED HEAT PUMP WATER HEATER WITH ROLLBOND EVAPORATOR
    Mutlu Cerit, Emine
    Erbay, L. Berrin
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2013, 33 (01) : 119 - 126
  • [9] Experimental investigation of the performance of a direct expansion solar assisted heat pump water heater with rollbond evaporator
    Rollbond buharlaştiricili doǧrudan genleşmel br isi pompasi su isiticisinin performansinin deneysel olarak ncelenmes
    [J]. 1600, Turk Isı Bilimi ve Teknigi Dernegi (33):
  • [10] Experimental performance analysis and optimization of a direct expansion solar-assisted heat pump water heater
    Li, Y. W.
    Wang, R. Z.
    Wu, J. Y.
    Xu, Y. X.
    [J]. ENERGY, 2007, 32 (08) : 1361 - 1374