Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology

被引:98
|
作者
Pradies, Guillermo [1 ]
Zarauz, Cristina [1 ]
Valverde, Arelhys [1 ]
Ferreiroa, Alberto [1 ]
Martinez-Rus, Francisco [1 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Buccofacial Prostheses, E-28040 Madrid, Spain
关键词
All-ceramic systems; CAD/CAM; Intraoral scanner; Internal gap; Marginal gap; Zirconia; FIXED PARTIAL DENTURES; PROCERA ALLCERAM CROWNS; MARGINAL FIT; INTERNAL FIT; ONE-STEP; CAD/CAM; ACCURACY; ZIRCONIA; SYSTEMS; RECOMMENDATIONS;
D O I
10.1016/j.jdent.2014.12.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this study was to compare the fit of ceramic crowns fabricated from conventional silicone impressions with the fit of ceramic crowns fabricated from intraoral digital impressions. Methods: Twenty-five participants with 30 posterior teeth with a prosthetic demand were selected for the study. Two crowns were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group) and the other crown was fabricated from a conventional two-step silicone impression (CI group). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone. Each crown was embedded in acrylic resin to stabilise the registered interface and then cut in 2 mm thick slices in a buco-lingual orientation. The internal gap was determined as the vertical distance from the internal surface of the crown to the prepared tooth surface at four points (marginal gap, axial gap, crest gap, and occlusal fossa gap) using stereomicroscopy with a magnification of 40x. Data was analysed by using Wilcoxon signed rank test (alpha = 0.05). Results: Internal adaptation values were significantly affected by the impression technique (p = 0.001). Mean marginal gap was 76.33 +/- 65.32 mu m for the crowns of the IDI group and 91.46 +/- 72.17 mu m for the CI group. Conclusion: All-ceramic crowns fabricated from intraoral digital impressions with wavefront sampling technology demonstrated better internal fit than crowns manufactured from silicone impressions. Clinical significance: Impressions obtained from an intraoral digital scanner based on wavefront sampling technology can be used for manufacturing ceramic crowns in the normal clinical practice with better results than conventional impressions with elastomers. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 16 条
  • [1] Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
    Zarauz, Cristina
    Valverde, Arelhys
    Martinez-Rus, Francisco
    Hassan, Bassam
    Pradies, Guillermo
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (04) : 799 - 806
  • [2] Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
    Cristina Zarauz
    Arelhys Valverde
    Francisco Martinez-Rus
    Bassam Hassan
    Guillermo Pradies
    [J]. Clinical Oral Investigations, 2016, 20 : 799 - 806
  • [3] Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    Syrek, Andreas
    Reich, Gunnar
    Ranftl, Dieter
    Klein, Christoph
    Cerny, Barbara
    Brodesser, Jutta
    [J]. JOURNAL OF DENTISTRY, 2010, 38 (07) : 553 - 559
  • [4] Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
    Berrendero, S.
    Salido, M. P.
    Valverde, A.
    Ferreiroa, A.
    Pradies, G.
    [J]. Clinical Oral Investigations, 2016, 20 (09) : 2403 - 2410
  • [5] Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns
    S. Berrendero
    M. P. Salido
    A. Valverde
    A. Ferreiroa
    G. Pradíes
    [J]. Clinical Oral Investigations, 2016, 20 : 2403 - 2410
  • [6] Comparative study of all-ceramic crowns obtained from conventional and digital impressions: clinical findings
    Santiago Berrendero
    Maria Paz Salido
    Alberto Ferreiroa
    Arelhys Valverde
    Guillermo Pradíes
    [J]. Clinical Oral Investigations, 2019, 23 : 1745 - 1751
  • [7] Comparative study of all-ceramic crowns obtained from conventional and digital impressions: clinical findings
    Berrendero, Santiago
    Paz Salido, Maria
    Ferreiroa, Alberto
    Valverde, Arelhys
    Pradies, Guillermo
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (04) : 1745 - 1751
  • [8] Clinical Evaluation of CAD/CAM Metal-Ceramic Posterior Crowns Fabricated from Intraoral Digital Impressions
    Tamim, Hazem
    Skjerven, Henrik
    Ekfeldt, Anders
    Ronold, Hans Jacob
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (04) : 331 - 337
  • [9] Accuracy and Efficiency of Digitally Fabricated All-Ceramic Crowns from Conventional Impressions and Intraoral Scans: A Single-Blind Clinical Randomized Controlled Trial
    Liu, Xinggang
    Feng, Kun
    Dong, Ling
    Liu, Lixia
    Ni, Lin
    Zheng, Dongxiang
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (01) : 8 - 15
  • [10] Marginal Fit Evaluation of CAD/CAM All Ceramic Crowns Obtained by Two Digital Workflows: An In Vitro Study Using Micro-CT Technology
    Duqum, Ibrahim Salim
    Brenes, Christian
    Mendonca, Gustavo
    Prado Naves Carneiro, Thiago Almedia
    Cooper, Lyndon F.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (09): : 1037 - 1043