Effect of Stimulus Polarity on Detection Thresholds in Cochlear Implant Users: Relationships with Average Threshold, Gap Detection, and Rate Discrimination

被引:29
|
作者
Carlyon, Robert P. [1 ]
Cosentino, Stefano [1 ]
Deeks, John M. [1 ]
Parkinson, Wendy [2 ]
Arenberg, Julie A. [2 ]
机构
[1] Univ Cambridge, MRC, Cognit & Brain Sci Unit, 15 Chaucer Rd, Cambridge CB2 7EF, England
[2] Univ Washington, Dept Speech & Hearing Sci, 1417 NE 42nd St, Seattle, WA 98105 USA
基金
英国医学研究理事会;
关键词
cochlear implants; polarity effects; detection thresholds; ELECTRODE-NEURON INTERFACE; ELECTRICAL-STIMULATION; SPEECH RECOGNITION; AUDITORY-NERVE; MULTIPULSE INTEGRATION; ACTION-POTENTIALS; TEMPORAL PITCH; PATTERNS; LOUDNESS; SITES;
D O I
10.1007/s10162-018-0677-5
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Previous psychophysical and modeling studies suggest that cathodic stimulation by a cochlear implant (CI) may preferentially activate the peripheral processes of the auditory nerve, whereas anodic stimulation may preferentially activate the central axons. Because neural degeneration typically starts with loss of the peripheral processes, lower thresholds for cathodic than for anodic stimulation may indicate good local neural survival. We measured thresholds for 99-pulse-per-second trains of triphasic (TP) pulses where the central high-amplitude phase was either anodic (TP-A) or cathodic (TP-C). Thresholds were obtained in monopolar mode from four or five electrodes and a total of eight ears from subjects implanted with the Advanced Bionics CI. When between-subject differences were removed, there was a modest but significant correlation between the polarity effect (TP-C threshold minus TP-A threshold) and the average of TP-C and TP-A thresholds, consistent with the hypothesis that a large polarity effect corresponds to good neural survival. When data were averaged across electrodes for each subject, relatively low thresholds for TP-C correlated with a high upper limit (the pulse rate up to which pitch continues to increase) from a previous study (Cosentino et al. J Assoc Otolaryngol 17:371-382). Overall, the results provide modest indirect support for the hypothesis that the polarity effect provides an estimate of local neural survival.
引用
收藏
页码:559 / 567
页数:9
相关论文
共 38 条
  • [1] Effect of Stimulus Polarity on Detection Thresholds in Cochlear Implant Users: Relationships with Average Threshold, Gap Detection, and Rate Discrimination
    Robert P. Carlyon
    Stefano Cosentino
    John M. Deeks
    Wendy Parkinson
    Julie A. Arenberg
    Journal of the Association for Research in Otolaryngology, 2018, 19 : 559 - 567
  • [2] Correction to: Effect of Stimulus Polarity on Detection Thresholds in Cochlear Implant Users: Relationships with Average Threshold, Gap Detection, and Rate Discrimination
    Robert P. Carlyon
    Stefano Cosentino
    John M. Deeks
    Wendy Parkinson
    Julie G. Arenberg
    Journal of the Association for Research in Otolaryngology, 2018, 19 : 569 - 569
  • [3] Effect of Stimulus Polarity on Detection Thresholds in Cochlear Implant Users: Relationships with Average Threshold, Gap Detection, and Rate Discrimination (vol 19, pg 559, 2018)
    Carlyon, Robert P.
    Cosentino, Stefano
    Deeks, John M.
    Parkinson, Wendy
    Arenberg, Julie G.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (05): : 569 - 569
  • [4] Rate modulation detection thresholds for cochlear implant users
    Brochier, Tim
    McKay, Colette
    McDermott, Hugh
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 143 (02): : 1214 - 1222
  • [5] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Cosentino, Stefano
    Carlyon, Robert P.
    Deeks, John M.
    Parkinson, Wendy
    Bierer, Julie A.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2016, 17 (04): : 371 - 382
  • [6] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Stefano Cosentino
    Robert P. Carlyon
    John M. Deeks
    Wendy Parkinson
    Julie A. Bierer
    Journal of the Association for Research in Otolaryngology, 2016, 17 : 371 - 382
  • [7] Relationship between gap detection thresholds and loudness in cochlear-implant users
    Garadat, Soha N.
    Pfingst, Bryan E.
    HEARING RESEARCH, 2011, 275 (1-2) : 130 - 138
  • [8] Influence of stimulus presentation rate on intraoperative ECAP thresholds in cochlear implant users
    Molisz, Andrzej
    Zarowski, Andrzej
    Theunen, Tinne
    Vermeiren, Annelies
    De Coninck, Liesbeth
    Przewozny, Tomasz
    Siebert, Janusz
    Offeciers, Erwin F.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2019, 58 (05) : 296 - 300
  • [9] Intensity discrimination and increment detection in cochlear-implant users
    Wojtczak, M. (wojtc@umn.edu), 1600, Acoustical Society of America (114):
  • [10] Intensity discrimination and increment detection in cochlear-implant users
    Wojtczak, M
    Donaldson, GS
    Viemeister, NF
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 114 (01): : 396 - 407