An Effective Algorithm for Beat-to-Beat Heart Rate Monitoring from Ballistocardiograms

被引:9
|
作者
Liang, Jingxian [1 ,2 ]
Huang, Jialin [1 ,2 ]
Mu, Liwei [1 ,2 ]
Yu, Baoxian [1 ,2 ]
Chen, Pengbin [3 ]
Pang, Zhiqiang [3 ]
Nie, Ruihua [2 ]
Zhang, Han [1 ,2 ,3 ]
机构
[1] South China Normal Univ, Dept Phys & Telecommun Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] South China Normal Univ, Guangdong Prov Res Ctr Cardiovasc Individual Med, Guangzhou 510006, Guangdong, Peoples R China
[3] Guangzhou SENVIV Technol Co Ltd, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Ballistocardiography (BCG); Beat-to-Beat Heart Rate Monitoring; Template Matching Approach; SENSOR;
D O I
10.1166/jmihi.2020.2910
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ballistocardiograms (BCG) is an essential signal for vital sign monitoring. Obtaining the beat-to-beat intervals from BCG signal is of great significance for home-care applications, such as sleep staging, heart disease alerting, etc. The current approaches of detecting beat-to-beat intervals from BCG signals are complex. In this paper, we develop a non-invasive BCG monitoring system, and propose an effective and accurate algorithm for beat-to-beat detection. Firstly, a heartbeat shape is adaptively modeled based on a two-step procedure by taking advantage of the J-peak and the K-valley of BCG signals. Then, forward and backward detections with the criteria of both the morphological distance and the cross-correlation are jointly employed to find the position of each BCG signal, and in turn, to determine the beat-to-beat intervals of BCG signals. The proposed method was validated in at least 90 minutes recording from 10 subjects in various setups. The mean absolute beat-to-beat intervals error was 10.72 ms and on an average 97.93% of the beat-to-beat intervals were detected.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 50 条
  • [1] Multiple Instance Dictionary Learning for Beat-to-Beat Heart Rate Monitoring From Ballistocardiograms
    Jiao, Changzhe
    Su, Bo-Yu
    Lyons, Princess
    Zare, Alina
    Ho, K. C.
    Skubic, Marjorie
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (11) : 2634 - 2648
  • [2] Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Stadlthanner, Kurt
    de Waele, Stijn
    Leonhardt, Steffen
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 778 - 786
  • [3] A Correlation-Based Algorithm for Beat-to-Beat Heart Rate Estimation from Ballistocardiograms
    Wen, Xin
    Huang, Yanqi
    Wu, Xiaomei
    Zhang, Biyong
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6355 - 6358
  • [4] Adaptive Heartbeat Modeling for Beat-to-Beat Heart Rate Measurement in Ballistocardiograms
    Paalasmaa, Joonas
    Toivonen, Hannu
    Partinen, Markku
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (06) : 1945 - 1952
  • [5] How Speech Processing Can Help With Beat-to-beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Winter, Stefan
    Leonhardt, Steffen
    [J]. 2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 12 - 16
  • [6] A BEAT-TO-BEAT HEART-RATE METER
    NIJHAWAN, SC
    SHARMA, VK
    KHANDPUR, RS
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (01) : 42 - 44
  • [7] DIGITAL BEAT-TO-BEAT HEART-RATE METER
    VOULGARIS, NC
    BAILAS, AA
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (02) : 181 - 183
  • [8] Beat-to-beat heart rate detection by smartphone accelerometers
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P. -F.
    Caiani, E. G.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 859 - 860
  • [9] Beat-to-beat adaptation of QT interval to heart rate
    Pueyo, Esther
    Malik, Marek
    Laguna, Pablo
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2475 - 2478
  • [10] An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform
    Alvarado-Serrano, Carlos
    Samuel Luna-Lozano, Pablo
    Pallas-Areny, Ramon
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 27 : 96 - 102