Anatomy and Physiology of Left Ventricular Suction Induced by Rotary Blood Pumps

被引:17
|
作者
Salamonsen, Robert Francis [1 ,3 ]
Lim, Einly [7 ]
Moloney, John [2 ,4 ]
Lovell, Nigel Hamilton [6 ]
Rosenfeldt, Franklin L. [5 ]
机构
[1] Monash Univ, Dept Epidemiol & Prevent Med, Melbourne, Vic 3004, Australia
[2] Monash Univ, Dept Anesthesia, Melbourne, Vic 3004, Australia
[3] Alfred Hosp, Intens Care Unit, Melbourne, Vic 3004, Australia
[4] Alfred Hosp, Dept Anesthesia & Perioperat Med, Melbourne, Vic 3004, Australia
[5] Alfred Hosp, Dept Cardiothorac Surg, Melbourne, Vic 3004, Australia
[6] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW, Australia
[7] Univ Maya, Dept Biomed Engn, Kuala Lumpur, Malaysia
关键词
Left ventricular assist device; Rotary blood pump; Left ventricular suction; Canine model; Heart failure; HEART-FAILURE PATIENTS; ASSIST DEVICES; ARRHYTHMIAS; MANAGEMENT; SYSTEM;
D O I
10.1111/aor.12550
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study in five large greyhound dogs implanted with a VentrAssist left ventricular assist device focused on identification of the precise site and physiological changes induced by or underlying the complication of left ventricular suction. Pressure sensors were placed in left and right atria, proximal and distal left ventricle, and proximal aorta while dual perivascular and tubing ultrasonic flow meters measured blood flow in the aortic root and pump outlet cannula. When suction occurred, end-systolic pressure gradients between proximal and distal regions of the left ventricle on the order of 40-160mmHg indicated an occlusive process of variable intensity in the distal ventricle. A variable negative flow difference between end systole and end diastole (0.5-3.4L/min) was observed. This was presumably mediated by variable apposition of the free and septal walls of the ventricle at the pump inlet cannula orifice which lasted approximately 100ms. This apposition, by inducing an end-systolic flow deficit, terminated the suction process by relieving the imbalance between pump requirement and delivery from the right ventricle. Immediately preceding this event, however, unnaturally low end-systolic pressures occurred in the left atrium and proximal left ventricle which in four dogs lasted for 80-120ms. In one dog, however, this collapse progressed to a new level and remained at approximately -5mmHg across four heart beats at which point suction was relieved by manual reduction in pump speed. Because these pressures were associated with a pulmonary capillary wedge pressure of -5mmHg as well, they indicate total collapse of the entire pulmonary venous system, left atrium, and left ventricle which persisted until pump flow requirement was relieved by reducing pump speed. We suggest that this collapse caused the whole vascular region from pulmonary capillaries to distal left ventricle to behave as a Starling resistance which further reduced right ventricular output thus contributing to a major reduction in pump flow. We contend that similar complications of manual speed control also occur in the human subject and remain a major unsolved problem in the clinical management of patients implanted with rotary blood pumps.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [1] Rotary Blood Pump Control Strategy for Preventing Left Ventricular Suction
    Wang, Yu
    Koenig, Steven C.
    Slaughter, Mark S.
    Giridharan, Guruprasad A.
    [J]. ASAIO JOURNAL, 2015, 61 (01) : 21 - 30
  • [2] Feedback Control of Rotary Blood Pump for Preventing Left Ventricular Suction
    Son, Jeongeun
    Du, Dongping
    Du, Yuncheng
    [J]. 2019 AMERICAN CONTROL CONFERENCE (ACC), 2019, : 5426 - 5431
  • [3] Left Ventricular Volume Unloading with Axial and Centrifugal Rotary Blood Pumps
    Giridharan, Guruprasad A.
    Koenig, Steven C.
    Soucy, Kevin G.
    Choi, Young
    Pirbodaghi, Tohid
    Bartoli, Carlo R.
    Monreal, Gretel
    Sobieski, Michael A.
    Schumer, Erin
    Cheng, Allen
    Slaughter, Mark S.
    [J]. ASAIO JOURNAL, 2015, 61 (03) : 292 - 300
  • [4] Reliable suction detection for patients with rotary blood pumps
    Mason, David G.
    Hilton, Andrew K.
    Salamonsen, Robert F.
    [J]. ASAIO JOURNAL, 2008, 54 (04) : 359 - 366
  • [5] Preload-Sensitive Control of Rotary Blood Pumps for Left Ventricular Assistance
    Arndt, Andreas
    Nuesser, Peter
    Lampe, Bernhard P.
    [J]. AT-AUTOMATISIERUNGSTECHNIK, 2010, 58 (05) : 241 - 250
  • [6] A suction index based control system for rotary blood pumps
    Liang, Lixue
    Meki, Moustafa
    Wang, Weibin
    Sethu, Palaniappan
    El-Baz, Ayman
    Giridharan, Guruprasad A.
    Wang, Yu
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 62
  • [7] A Control System for Rotary Blood Pumps Based on Suction Detection
    Ferreira, Antonio
    Boston, J. Robert
    Antaki, James F.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (03) : 656 - 665
  • [8] A Gaussian Mixture Model to Detect Suction Events in Rotary Blood Pumps
    Tzallas, Alexandros T.
    Rigas, George
    Karvounis, Evaggelos C.
    Tsipouras, Markos G.
    Goletsis, Yorgos
    Zielinski, Krzysztof
    Fresiello, Libera
    Fotiadis, Dimitrios I.
    Trivella, Maria G.
    [J]. IEEE 12TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS & BIOENGINEERING, 2012, : 127 - 131
  • [9] Mathematical modeling of ventricular suction induced by a rotary ventricular assist device
    Yu, Yih-Choung
    Porter, Joshua
    [J]. 2006 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2006, 1-12 : 707 - +
  • [10] Continuously maintaining positive flow avoids endocardial suction of a rotary blood pump with left ventricular bypass
    Akimoto, T
    Yamazaki, K
    Litwak, P
    Litwak, KN
    Tagusari, O
    Mori, T
    Antaki, JF
    Kameneva, MV
    Watach, MJ
    Umezu, M
    Tomioka, J
    Kormos, RL
    Koyanagi, H
    Griffith, BP
    [J]. ARTIFICIAL ORGANS, 2000, 24 (08) : 606 - 610