Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combination

被引:1
|
作者
Lee, Sang-Kwon [1 ,2 ]
Lee, Juryeoung [1 ,2 ]
Jang, Seolyn [1 ,2 ]
Lee, Eunji [1 ,2 ]
Jeon, Chang-Yeop [3 ]
Lim, Kyung-Seoub [4 ]
Jin, Yeung Bae [5 ]
Choi, Jihye [1 ,2 ]
机构
[1] Chonnam Natl Univ, Coll Vet Med, Gwangju, South Korea
[2] Chonnam Natl Univ, BK21 Plus Project Team, Gwangju, South Korea
[3] Korea Res Inst Biosci & Biotechnol, Natl Primate Res Ctr, Cheongju, South Korea
[4] Korea Res Inst Biosci & Biotechnol, Futurist Anim Resource & Res Ctr, Cheongju, South Korea
[5] Gyeongsang Natl Univ, Coll Vet Med, Jinju, South Korea
基金
新加坡国家研究基金会;
关键词
canine; diffusion-weighted magnetic resonance imaging; kidney; renal fibrosis; b-value; INTRAVOXEL INCOHERENT MOTION; CHRONIC KIDNEY-DISEASE; FUNCTIONAL-EVALUATION; FIBROSIS; MRI; MODEL; COEFFICIENT; HYDRATION; PERFUSION; IVIM;
D O I
10.3389/fvets.2021.641971
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Diffusion-weighted imaging (DWI) magnetic resonance imaging can evaluate alterations in the microstructure of the kidney. The purpose of this study was to assess the apparent diffusion coefficient (ADC) and the intravoxel incoherent motion model (IVIM) parameters of a normal kidney in healthy dogs, to evaluate the effect of b-value combinations on the ADC value, and the reproducibility and test-retest repeatability in monoexponential and IVIM analysis. In this experimental study, the ADC, pure diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f (p)) were measured from both kidneys in nine healthy beagles using nine b-values (b = 0, 50, 70, 100, 150, 200, 500, 800, and 1,000 s/mm(2)) twice with a 1-week interval between measurements. Interobserver and intraobserver reproducibility, and test-retest repeatability of the measurements were calculated. ADC values were measured using 10 different b-value combinations consisting of three b-values each, and were compared to the ADC obtained from nine b-values. All the ADC, D, D*, and f (p) values measured from the renal cortex, medulla, and the entire kidney had excellent interobserver and intraobserver reproducibility, and test-retest repeatability. The ADC obtained from a b-value combination of 0, 100, and 800 s/mm(2) had the highest intraclass correlation coefficient with the ADC from nine b-values. The results of this study indicated that DWI MRI using multiple b-values is feasible for the measurement of ADC and IVIM parameters with high reproducibility and repeatability in the kidneys of healthy dogs. A combination of b = 0, 100, and 800 s/mm(2) can be used for ADC measurements when multiple b-values are not available in dogs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Diffusion-weighted (DW) MRI in lung cancers: ADC test-retest repeatability
    Alex Weller
    Marianthi Vasiliki Papoutsaki
    John C. Waterton
    Arturo Chiti
    Sigrid Stroobants
    Joost Kuijer
    Matthew Blackledge
    Veronica Morgan
    Nandita M deSouza
    [J]. European Radiology, 2017, 27 : 4552 - 4562
  • [2] Diffusion-weighted (DW) MRI in lung cancers: ADC test-retest repeatability
    Weller, Alex
    Papoutsaki, Marianthi Vasiliki
    Waterton, John C.
    Chiti, Arturo
    Stroobants, Sigrid
    Kuijer, Joost
    Blackledge, Matthew
    Morgan, Veronica
    deSouza, Nandita M.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (11) : 4552 - 4562
  • [3] Diffusion-weighted imaging of prostate cancer: effect of b-value distribution on repeatability and cancer characterization
    Merisaari, Harri
    Toivonen, Jussi
    Pesola, Marko
    Taimen, Pekka
    Bostrom, Peter J.
    Pahikkala, Tapio
    Aronen, Hannu J.
    Jambor, Ivan
    [J]. MAGNETIC RESONANCE IMAGING, 2015, 33 (10) : 1212 - 1218
  • [4] Test-retest repeatability of ADC in prostate using the multi b-Value VERDICT acquisition
    Rogers, Harriet J.
    Singh, Saurabh
    Barnes, Anna
    Obuchowski, Nancy A.
    Margolis, Daniel J.
    Malyarenko, Dariya I.
    Chenevert, Thomas L.
    Shukla-Dave, Amita
    Boss, Michael A.
    Punwani, Shonit
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2023, 162
  • [5] Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects
    Cutajar, Marica
    Clayden, Jonathan D.
    Clark, Christopher A.
    Gordon, Isky
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E263 - E268
  • [6] Optimization of b-value sampling for diffusion-weighted imaging of the kidney
    Zhang, Jeff L.
    Sigmund, Eric E.
    Rusinek, Henry
    Chandarana, Hersh
    Storey, Pippa
    Chen, Qun
    Lee, Vivian S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 89 - 97
  • [7] Diffusion-weighted imaging of rectal cancer on repeatability and cancer characterization: an effect of b-value distribution study
    Luguang Chen
    Fu Shen
    Zhihui Li
    Haidi Lu
    Yukun Chen
    Zhen Wang
    Jianping Lu
    [J]. Cancer Imaging, 18
  • [8] Diffusion-weighted imaging of rectal cancer on repeatability and cancer characterization: an effect of b-value distribution study
    Chen, Luguang
    Shen, Fu
    Li, Zhihui
    Lu, Haidi
    Chen, Yukun
    Wang, Zhen
    Lu, Jianping
    [J]. CANCER IMAGING, 2018, 18
  • [9] Model selection for high b-value diffusion-weighted MRI of the prostate
    Mazaheri, Yousef
    Hotker, Andreas M.
    Shukla-Dave, Amita
    Akin, Oguz
    Hricak, Hedvig
    [J]. MAGNETIC RESONANCE IMAGING, 2018, 46 : 21 - 27
  • [10] Diffusion-weighted MRI and optimal b-value for characterization of liver lesions
    Kaya, Bilal
    Koc, Zafer
    [J]. ACTA RADIOLOGICA, 2014, 55 (05) : 532 - 542