Self-Calibrated Absolute Thickness Measurement of Opaque Specimen Based on Differential White Light Interferometry

被引:13
|
作者
Lu, Xu [1 ,2 ]
Yuan, Yonggui [1 ,3 ]
Ma, Chi [1 ,2 ]
Zhu, Haibo [1 ,2 ]
Zhu, Yunlong [1 ,2 ]
Yu, Zhangjun [1 ,2 ]
Zhang, Xiaojun [1 ,2 ]
Jiang, Fuqiang [1 ,2 ]
Zhang, Jianzhong [1 ,2 ]
Li, Hanyang [1 ,2 ]
Yang, Jun [1 ,4 ]
Yuan, Libo [1 ,5 ]
机构
[1] Harbin Engn Univ, Key Lab In Fiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Harbin Engn Univ, Coll Phys & Optoelect Engn, Harbin 150001, Peoples R China
[3] Harbin Engn Univ, Coll Informat & Commun Engn, Harbin 150001, Peoples R China
[4] Guangdong Univ Technol, Sch Informat Engn, Guangzhou 510008, Peoples R China
[5] Guilin Univ Elect Technol, Photon Res Ctr, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
Measurement uncertainty analysis; opaque specimens; self-calibration; thickness measurement; white light interferometry; ZNO THIN-FILMS;
D O I
10.1109/TIM.2020.2966315
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, we present a self-calibrated absolute thickness measurement method for opaque specimens based on fiber-optic white light interferometry. A new type of self-reference probe, which is composed of a fiber ferrule, an integrated beam splitter, and a gradient index lens, is presented. In our setup, two probes of this kind are fixed facing each other, and the distance between them can be measured. Then we insert a specimen between the probes and measure the distance between the specimen surfaces and probes on both sides. Thisway, a self-calibrated measurement of specimen thickness can be realized without the traditional calibration process using a standard thickness sample. Thus, the uncertainty component introduced by the standard thickness sample can be eliminated. The performance of the proposed method is evaluated by measuring standard thickness samples calibrated by the National Institute of Metrology of China, and the results show a good agreement with the nominal values. Also, we analyzed several key uncertainty components, as well as the reliability of our method. The calculated extended measurement uncertainty (k = 2) is 0.06 mu m for Cr specimen with a nominal thickness of 10.56, and 0.08 mu m for Ni specimen with a nominal thickness of 31.46 mu m.
引用
收藏
页码:2507 / 2514
页数:8
相关论文
共 50 条
  • [1] Fiber optic white light interferometry for self-calibrated, absolute strain measurements
    Bhatia, V
    Murphy, KA
    Claus, RO
    Tran, TA
    Greene, JA
    [J]. SELF-CALIBRATED INTELLIGENT OPTICAL SENSORS AND SYSTEMS, 1996, 2594 : 168 - 177
  • [2] Thin-film Thickness Absolute Measurement by Differential Optic-fiber White Light Interferometry
    Lu, Xu
    Yu, Zhangjun
    Yang, Jun
    Yuan, Yonggui
    Li, Hanyang
    Yuan, Libo
    [J]. 2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 1009 - 1013
  • [3] Simultaneous Measurement of Thickness and Group Refractive Index Based on Differential White Light Interferometry
    Lu, Xu
    Wang, Xinkai
    Zhu, Yunlong
    Yuan, Yonggui
    Dang, Fanyang
    Zhu, Yao
    Yu, Zhangjun
    Yang, Jun
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [4] Self-Calibrated Measurement Method Based on Structured Illumination Microscopy
    Liu, Lei
    Tang, Yan
    Wei, Haojie
    He, Yu
    Hu, Song
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2021, 33 (19) : 1097 - 1100
  • [5] Self-calibrated frequency response measurement of photodetectors based on photonic sampling
    Jing, Chao
    He, Yutong
    Zhang, Yali
    Zhang, Zhiyao
    Zhang, Shangjian
    Liu, Yong
    [J]. OPTOELECTRONIC DEVICES AND INTEGRATION XI, 2022, 12314
  • [6] Non-contact thickness measurement of metal foil by means of differential white light interferometry
    Du, YL
    Yan, HM
    Wu, Y
    Yao, XQ
    Nie, YJ
    Shi, BX
    [J]. OPTICAL DESIGN AND TESTING II, PTS 1 AND 2, 2005, 5638 : 850 - 857
  • [7] Thickness measurement of transparent film by white-light interferometry
    Deng, Qinyuan
    Zhou, Yi
    Liu, Junbo
    Yao, Jingwei
    Hu, Song
    [J]. 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: DESIGN, MANUFACTURING, AND TESTING OF MICRO- AND NANO-OPTICAL DEVICES AND SYSTEMS; AND SMART STRUCTURES AND MATERIALS, 2016, 9685
  • [8] Measurement of transparent coating thickness by the use of white light interferometry
    Li, MZ
    Quan, CG
    Tay, CJ
    Reading, I
    Wang, SH
    [J]. THIRD INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS AND THIRD CONFERENCE OF THE ASIAN-COMMITTEE-ON-EXPERIMENTAL-MECHANICS, PTS 1AND 2, 2005, 5852 : 401 - 406
  • [9] ABSOLUTE SPECTRAL IRRADIANCE MEASUREMENTS BASED ON A SELF-CALIBRATED SILICON PHOTO-DIODE
    ZALEWSKI, EF
    GLADDEN, WK
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1981, 71 (12) : 1627 - 1627
  • [10] Initial estimation of thin film thickness measurement based on white light spectral interferometry
    Guo, Tong
    Wu, Juhong
    Ni, Lianfeng
    Fu, Xing
    Hu, Xiaotang
    [J]. THIN SOLID FILMS, 2016, 612 : 267 - 273