Estimation of delivered dose to lung tumours considering setup uncertainties and breathing motion in a cohort of patients treated with stereotactic body radiation therapy

被引:7
|
作者
Karlsson, Kristin [1 ,2 ]
Lax, Ingmar [1 ,2 ]
Lindback, Elias [1 ,2 ]
Grozman, Vitali [3 ,4 ]
Lindberg, Karin [2 ,5 ]
Wersall, Peter [2 ,6 ]
Poludniowski, Gavin [2 ,7 ]
机构
[1] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Sect Radiotherapy Phys & Engn, Stockholm, Sweden
[2] Karolinska Inst, Dept Oncol & Pathol, Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Radiol, Sect Thorac Radiol, Stockholm, Sweden
[4] Karolinska Inst, Dept Mol Med & Surg, Stockholm, Sweden
[5] Karolinska Univ Hosp, Dept Canc, Sect Head Neck Lung & Skin Tumours, Stockholm, Sweden
[6] Karolinska Univ Hosp, Dept Canc, Sect Radiotherapy, Stockholm, Sweden
[7] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, Stockholm, Sweden
关键词
Stereotactic body radiation therapy; Delivered CTV dose; Geometrical uncertainties; Dose-shift; CALCULATION ALGORITHMS; RADIOTHERAPY SBRT; DOSIMETRIC IMPACT; CANCER; MARGINS; PROBABILITY; EFFICACY; ACCURACY; ERRORS; FRAME;
D O I
10.1016/j.ejmp.2021.06.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Dose-response relationships for local control of lung tumours treated with stereotactic body radiotherapy (SBRT) have proved ambiguous, however, these have been based on the prescribed or planned dose. Delivered dose to the target may be a better predictor for local control. In this study, the probability of the delivered minimum dose to the clinical target volume (CTV) in relation to the prescribed dose was estimated for a cohort of patients, considering geometrical uncertainties. Materials and methods: Delivered doses were retrospectively simulated for 50 patients treated with SBRT for lung tumours, comparing two image-guidance techniques: pre-treatment verification computed tomography (IG1) and online cone-beam computed tomography (IG2). The prescribed dose was typically to the 67% isodose line of the treatment plan. Simulations used in-house software that shifted the static planned dose according to a breathing motion and sampled setup/matching errors. Each treatment was repeatedly simulated, generating a multiplicity of dose-volume histograms (DVH). From these, tumour-specific and population-averaged statistics were derived. Results: For IG1, the probability that the minimum CTV dose (D98%) exceeded 100% of the prescribed dose was 90%. With IG2, this probability increased to 99%. Conclusions: Doses below the prescribed dose were delivered to a considerably larger part of the population prior to the introduction of online soft-tissue image-guidance. However, there is no clear evidence that this impacts local control, when compared to previous published data.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 50 条
  • [1] Setup Uncertainties for the Lung Stereotactic Body Radiation Therapy
    Zhang, Q.
    Cao, Y.
    Jamshidi, A.
    Vigneri, P.
    Madu, C.
    Potters, L.
    Klein, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3363 - 3363
  • [2] Impact of lung tumor motion on dose delivered to organ at risk in lung stereotactic body radiation therapy
    Savanovic, Milovan
    Strbac, Bojan
    Jaros, Drazan
    Cazic, Dejan
    Foulquier, Jean Noel
    JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (3-4) : 191 - 198
  • [3] PREDICTIVE FACTORS OF SYMPTOMATIC RADIATION-INDUCED LUNG INJURY IN PATIENTS TREATED WITH STEREOTACTIC BODY RADIATION THERAPY FOR LUNG TUMOURS
    Ricardi, U.
    Filippi, A. R.
    Guarneri, A.
    Giglioli, F.
    Mantovani, C.
    Fiandra, C.
    Anglesio, S.
    Ragona, R.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S462 - S463
  • [4] Esophageal Dose Tolerance in Patients Treated With Stereotactic Body Radiation Therapy
    Nuyttens, Joost J.
    Moiseenko, Vitali
    McLaughlin, Mark
    Jain, Sheena
    Herbert, Scott
    Grimm, Jimm
    SEMINARS IN RADIATION ONCOLOGY, 2016, 26 (02) : 120 - 128
  • [5] Impact of Breathing Periods on Dose Uncertainties for Lung Volumetric Modulated Arc Therapy-Stereotactic Body Radiation Therapy: A Novel FFT Approach
    Zhu, X.
    Zhang, M.
    Verma, V.
    Zheng, D.
    Lei, Y.
    Li, S.
    Wang, S.
    Bennion, N. R.
    Zhen, W.
    Enke, C. A.
    Zhou, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E648 - E649
  • [6] Interfraction Regional Variation of Tumor Breathing Motion in Lung Stereotactic Body Radiation Therapy (SBRT)
    Atkins, K.
    Varchani, A.
    Nam, T. L.
    Fuss, M.
    Tanyi, J. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S68 - S69
  • [7] Temporal Dose-Response of Normal Lung Tissue in Patients Treated with Stereotactic Body Radiation Therapy for Lung Tumors
    Diot, Q.
    Kavanagh, B.
    Gaspar, L.
    Raben, D.
    Stuhr, K.
    Miften, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Radiation induced dyspnea in lung cancer patients treated with stereotactic body radiation therapy
    Palma, G.
    Monti, S.
    Thor, M.
    Rimner, A.
    Deasy, J.
    Cella, L.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S235 - S236
  • [9] STEREOTACTIC BODY RADIATION THERAPY FOR PATIENTS WITH LUNG CANCER PREVIOUSLY TREATED WITH THORACIC RADIATION
    Kelly, Patrick
    Balter, Peter A.
    Rebueno, Neal
    Sharp, Hadley J.
    Liao, Zhongxing
    Komaki, Ritsuko
    Chang, Joe Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1387 - 1393
  • [10] Esophageal Dose Tolerance in Patients Treated With Stereotactic Body Radiation Therapy (SBRT)
    Nuyttens, J.
    Moiseenko, V.
    Grimm, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E474 - E475