Ablation of carious dental tissue using an ultrashort pulsed laser (USPL) system

被引:4
|
作者
Engelbach, Christoph [1 ]
Dehn, Claudia [1 ]
Bourauel, Christoph [2 ]
Meister, Joerg [1 ,3 ]
Frentzen, Matthias [1 ]
机构
[1] Univ Bonn, Fac Dent, Dept Operat & Prevent Dent, D-53111 Bonn, Germany
[2] Univ Bonn, Fac Dent, Oral Technol, D-53111 Bonn, Germany
[3] Rhein Westfal TH Aachen, Fac Med, Dept Conservat Dent Periodontol & Prevent Dent, Aachen, Germany
关键词
Ultrashort pulsed laser; Enamel; Dentin; Caries ablation; Ablation rate; Surface roughness; ER-YAG-LASER; BOND-STRENGTH; IN-VITRO; CARIES-EXCAVATION; PICOSECOND LASER; PHOSPHORIC-ACID; HARD SUBSTANCES; REPETITION RATE; ENAMEL; COMPOSITE;
D O I
10.1007/s10103-014-1594-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the study was to investigate the efficiency of caries removal employing an ultrashort pulsed laser (USPL) and to compare the results regarding to the ablation rate of sound enamel and dentin including surface texture. The study was performed with 59 freshly extracted carious human teeth. Two cavities with an edge length of 1 x 1 mm per tooth were created: one in the dental decay and one in sound hard tissue. For this purpose a 9-W Nd:YVO4 laser with a center wavelength of 1,064 nm and a pulse duration of 8 ps at a repetition rate of 500 kHz was used. A scanner system moved the laser beam across the surface with a scan speed of 2,000 mm/s. Ablated volume and roughness R (z) of the cavity ground were measured using an optical profilometer. Subsequently, the specimens were cut to undecalcified sections for histological investigations. The removal of dental decay (dentin, 14.9 mm(3)/min; enamel, 12.8 mm(3)/min) was significantly higher (p < 0.05) compared to the removal of sound tissues (dentin, 4.2 mm(3)/min; enamel, 3.8 mm(3)/min). The arithmetic means of the surface roughness R (z) were 8.5 mu m in carious enamel, 15.43 mu m in carious dentin, 4.83 mu m in sound enamel and 5.52 mu m in sound dentin. Light microscopic investigations did not indicate any side effects in the surrounding tissues. Regarding the ablation rate of dental decay using the USPL system, caries removal seems to be much more efficient for cavity preparation.
引用
收藏
页码:1427 / 1434
页数:8
相关论文
共 50 条
  • [1] Ablation of carious dental tissue using an ultrashort pulsed laser (USPL) system
    Christoph Engelbach
    Claudia Dehn
    Christoph Bourauel
    Jörg Meister
    Matthias Frentzen
    Lasers in Medical Science, 2015, 30 : 1427 - 1434
  • [2] Erratum to: Ablation of carious dental tissue using an ultrashort pulsed laser (USPL) system
    Christoph Engelbach
    Claudia Dehn
    Oliver Brede
    Andreas Braun
    Florian Schelle
    Christoph Bourauel
    Jörg Meister
    Matthias Frentzen
    Lasers in Medical Science, 2016, 31 : 1983 - 1983
  • [3] Ablation of carious dental tissue using an ultrashort pulsed laser (USPL) system (vol 30, pg 1427, 2015)
    Engelbach, Christoph
    Dehn, Claudia
    Brede, Oliver
    Braun, Andreas
    Schelle, Florian
    Bourauel, Christoph
    Meister, Joerg
    Frentzen, Matthias
    LASERS IN MEDICAL SCIENCE, 2016, 31 (09) : 1983 - 1983
  • [4] Ablation of porcine bone tissue with an ultrashort pulsed laser (USPL) system
    Ploetz, Christina
    Schelle, Florian
    Bourauel, Christoph
    Frentzen, Matthias
    Meister, Joerg
    LASERS IN MEDICAL SCIENCE, 2015, 30 (03) : 977 - 983
  • [5] Ablation of porcine bone tissue with an ultrashort pulsed laser (USPL) system
    Christina Plötz
    Florian Schelle
    Christoph Bourauel
    Matthias Frentzen
    Jörg Meister
    Lasers in Medical Science, 2015, 30 : 977 - 983
  • [6] Imaging of Dental Hard Tissue Surfaces Prepared by an Ultrashort Pulsed Laser System (USPL)
    Schaeper, Matthias
    Reimann, Susanne
    Frentzen, Matthias
    Meister, Joerg
    MICROSCOPY AND MICROANALYSIS, 2016, 22 (06) : 1189 - 1197
  • [7] Heat generation caused by ablation of dental hard tissues with an ultrashort pulse laser (USPL) system
    Braun, Andreas
    Krillke, Raphael Franz
    Frentzen, Matthias
    Bourauel, Christoph
    Stark, Helmut
    Schelle, Florian
    LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 475 - 481
  • [8] Heat generation caused by ablation of dental hard tissues with an ultrashort pulse laser (USPL) system
    Andreas Braun
    Raphael Franz Krillke
    Matthias Frentzen
    Christoph Bourauel
    Helmut Stark
    Florian Schelle
    Lasers in Medical Science, 2015, 30 : 475 - 481
  • [9] Heat generation caused by ablation of restorative materials with an ultrashort pulse laser (USPL) system
    Andreas Braun
    Richard Johannes Wehry
    Olivier Brede
    Claudia Dehn
    Matthias Frentzen
    Florian Schelle
    Lasers in Medical Science, 2012, 27 : 297 - 303
  • [10] Heat generation caused by ablation of restorative materials with an ultrashort pulse laser (USPL) system
    Braun, Andreas
    Wehry, Richard Johannes
    Brede, Olivier
    Dehn, Claudia
    Frentzen, Matthias
    Schelle, Florian
    LASERS IN MEDICAL SCIENCE, 2012, 27 (02) : 297 - 303