Registration of pencil beam proton radiography data with X-ray CT

被引:13
|
作者
Deffet, Sylvain [1 ]
Macq, Benoit [1 ]
Righetto, Roberto [2 ]
Stappen, Francois Vander [3 ]
Farace, Paolo [2 ]
机构
[1] Catholic Univ Louvain, Inst Informat & Commun Technol, B-1348 Louvain La Neuve, Belgium
[2] Hosp Trento, Proton Therapy Unit, I-38122 Trento, Italy
[3] Med Accelerators Solut R&D, IBA, B-1348 Louvain, Belgium
关键词
multilayer ionization chamber; particle imaging; proton radiography; range uncertainty; registration; MULTILAYER IONIZATION-CHAMBER; STOPPING-POWER; RANGE UNCERTAINTIES; THERAPY; VERIFICATION; OPTIMIZATION;
D O I
10.1002/mp.12497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Proton radiography seems to be a promising tool for assessing the quality of the stopping power computation in proton therapy. However, range error maps obtained on the basis of proton radiographs are very sensitive to small misalignment between the planning CT and the proton radiography acquisitions. In order to be able to mitigate misalignment in postprocessing, the authors implemented a fast method for registration between pencil proton radiography data obtained with a multilayer ionization chamber (MLIC) and an X-ray CT acquired on a head phantom. Methods: The registration was performed by optimizing a cost function which performs a comparison between the acquired data and simulated integral depth-dose curves. Two methodologies were considered, one based on dual orthogonal projections and the other one on a single projection. For each methodology, the robustness of the registration algorithm with respect to three confounding factors (measurement noise, CT calibration errors, and spot spacing) was investigated by testing the accuracy of the method through simulations based on a CT scan of a head phantom. Results: The present registration method showed robust convergence towards the optimal solution. For the level of measurement noise and the uncertainty in the stopping power computation expected in proton radiography using a MLIC, the accuracy appeared to be better than 0.3 degrees for angles and 0.3 mm for translations by use of the appropriate cost function. The spot spacing analysis showed that a spacing larger than the 5 mm used by other authors for the investigation of a MLIC for proton radiography led to results with absolute accuracy better than 0.3 degrees for angles and 1 mm for translations when orthogonal proton radiographs were fed into the algorithm. In the case of a single projection, 6 mm was the largest spot spacing presenting an acceptable registration accuracy. Conclusions: For registration of proton radiography data with X-ray CT, the use of a direct ray-tracing algorithm to compute sums of squared differences and corrections of range errors showed very good accuracy and robustness with respect to three confounding factors: measurement noise, calibration error, and spot spacing. It is therefore a suitable algorithm to use in the in vivo range verification framework, allowing to separate in postprocessing the proton range uncertainty due to setup errors from the other sources of uncertainty. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:5393 / 5401
页数:9
相关论文
共 50 条
  • [1] Proton Beam X-Ray Fluorescence CT
    Bazalova, M.
    Ahmad, M.
    Fahrig, R.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 449 - 449
  • [2] Stopping power measurement for proton therapy by combining proton radiography and X-ray CT
    Kataura, R.
    Izumikawa, T.
    Konno, T.
    Kawasaki, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [3] Proton Beam Imaging Using X-Ray Flat Panel for a Pencil Beam Scanning System
    Finley, C.
    Jee, K.
    Zwart, T.
    Sharp, G.
    Huo, W.
    Jones, M.
    Huang, K.
    Catanzano, D.
    Nyamane, S.
    Cooley, J.
    Rosenthal, S.
    Lu, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3145 - 3145
  • [4] Adjustment of CT calibration in presence of titanium implants by pencil beam proton radiography
    Righetto, R.
    Meijers, A.
    Vander Stappen, F.
    Farace, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S441 - S442
  • [5] Proton radiography to calibrate relative proton stopping power from X-ray CT in proton radiotherapy
    Biegun, A. K.
    Marin, K. Ortega
    Brandenburg, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S817 - S818
  • [6] X-RAY BEAM PROFILES AND ORAL RADIOGRAPHY
    WEISSMAN, DD
    FEINSTEIN, RB
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1971, 31 (04): : 546 - +
  • [7] Influence of Detection Angle on the Quality of Pencil-Beam X-Ray Fluorescence CT
    Ma Zhizhen
    Jiang Shanghai
    Luo Binbin
    Shi Shenghui
    Zou Xue
    Tang Bin
    Wu Decao
    Zhao Mingfu
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (16)
  • [8] X-Ray Fluorescence CT Induced by Proton Beam: Experiments and Simulations
    Bazalova-Carter, M.
    Ahmad, M.
    Matsuura, T.
    Takao, S.
    Matsuo, Y.
    Fahrig, R.
    Shirato, H.
    Umegaki, K.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3716 - 3716
  • [9] X-ray pencil beam facility for optics characterization
    Krumrey, Michael
    Cibik, Levent
    Mueller, Peter
    Bavdaz, Marcos
    Wille, Eric
    Ackermann, Marcelo
    Collon, Maximilien J.
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [10] PROTON-INDUCED CHARACTERISTIC X-RAY RADIOGRAPHY
    THOMSON, GM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1335 - 1338