Image guidance in external beam accelerated partial breast irradiation: Comparison of surrogates for the lumpectomy cavity

被引:32
|
作者
Hasan, Yasmin [1 ]
Kim, Leonard [1 ]
Martinez, Alvaro [1 ]
Vicini, Frank [1 ]
Yan, Di [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 70卷 / 02期
关键词
partial breast irradiation; image guidance; cavity localization; clip registration; surface registration;
D O I
10.1016/j.ijrobp.2007.08.079
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To compare localization of the lumpectomy cavity by using breast surface matching vs. clips for image-guided external beam accelerated partial breast irradiation. Methods and Materials: Twenty-seven patients with breast cancer with two computed tomography (CT) scans each had three CT registrations performed: (1) to bony anatomy, (2) to the center of mass (COM) of surgical clips, and (3) to the breast surface. The cavity COM was defined in both the initial and second CT scans after each type of registration, and distances between COMs (Delta COMBone, Delta COMClips, and Delta COMSurface) were determined. Smaller Delta COMs were interpreted as better localizations. Correlation coefficients were calculated for Delta COM vs. several variables. Results: The Delta COMBone (mean, 7 +/- 2 [SD] mm) increased with breast volume (r = 0.4; p = 0.02) and distance from the chest wall (r = 0.5; p = 0.003). Relative to bony registration, clip registration provided better localization (Delta COMClips < Delta COMBone) in 25 of 27 cases. Breast surface matching improved cavity localization (Delta COMSurface <Delta COMBone) in 19 of 27 cases. Mean improvements (Delta COMBone - Delta COMClips or Surface) were 4 +/- 3 and 2 +/- 4 mm, respectively. In terms of percentage of improvement ([Delta COMBone - Delta COMClips or Surface]/Delta COMBone), only surface matching showed a correlation with breast volume. Clip localization outperformed surface registration for cavities located superior to the breast COM. Conclusions: Use of either breast surface or surgical clips as surrogates for the cavity results in improved localization in most patients compared with bony registration and may allow smaller planning target volume margins for external beam accelerated partial breast irradiation. Compared with surface registration, clip registration may be less sensitive to anatomic characteristics and therefore more broadly applicable. (C) 2008 Elsevier Inc.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 50 条
  • [1] Image guidance in external beam accelerated partial breast irradiation: Comparison of surrogates for the lumpectomy cavity
    Hasan, Y
    Kim, L
    Weed, D
    Kestin, L
    Martinez, A
    Vicini, F
    Yan, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S138 - S138
  • [2] Is the lumpectomy cavity the gold standard for image guidance in accelerated partial breast irradiation?
    DeCesare, S.
    Kim, L.
    Zhang, T.
    Vicini, F.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S509 - S510
  • [3] Real-time Lumpectomy Cavity Motion during External Beam Accelerated Partial Breast Irradiation
    Afghan, M. K.
    Ye, J.
    Wong, T. P.
    Eulau, S. M.
    Mate, T.
    Zeller, T.
    Shepard, D. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S585 - S585
  • [4] Image guidance for external beam partial breast irradiation
    Wahab, S. H.
    Zhao, H.
    Klein, E.
    Taylor, M.
    Zoberi, I.
    Rey, F.
    Powell, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S25 - S25
  • [5] Video surface image guidance for external beam partial breast irradiation
    Chang, Albert J.
    Zhao, Hui
    Wahab, Sasha Hyatt
    Moore, Kevin
    Taylor, Marie
    Zoberi, Imran
    Powell, Simon N.
    Klein, Eric E.
    PRACTICAL RADIATION ONCOLOGY, 2012, 2 (02) : 97 - 105
  • [6] Uncertainties in target volume surrogates in image guided external beam partial breast irradiation
    Gierga, D. P.
    Turcotte, J. C.
    Sharp, G. C.
    Ribold, M.
    Franke, A.
    Jiang, S. B.
    Chen, G. T. Y.
    MEDICAL PHYSICS, 2006, 33 (06) : 2050 - 2050
  • [7] Accelerated partial breast irradiation with external beam radiotherapy
    Ott, Oliver J.
    Strnad, Vratislav
    Stillkrieg, Wilhelm
    Uter, Wolfgang
    Beckmann, MatthiasW.
    Fietkau, Rainer
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 (01) : 55 - 61
  • [8] The validity of surgical clips as a radiographic surrogate for the lumpectomy cavity in image-guided accelerated partial breast irradiation
    Weed, DW
    Yan, D
    Martinez, AA
    Vicini, FA
    Wilkinson, TJ
    Wong, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 484 - 492
  • [9] Dosimetric impact of two image guidance methods for external beam partial breast irradiation
    Wahab, S.
    Zhao, H.
    Klein, E.
    Taylor, M.
    Rey, F.
    Powell, S.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S63 - S63
  • [10] Measurement of dose exposure of image guidance in external beam accelerated partial breast irradiation: Evaluation of different techniques and linear accelerators
    Stelczer, Gabor
    Tatai-Szabo, Dora
    Major, Tibor
    Meszaros, Norbert
    Polgar, Csaba
    Palvolgyi, Jeno
    Pesznyak, Csilla
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 63 : 70 - 78