Action Levels on Dose and Anatomic Variation for Adaptive Radiation Therapy Using Daily Offline Plan Evaluation: Preliminary Results

被引:7
|
作者
Zhang, Baoshe [1 ]
Lee, Sung-Woo [1 ]
Chen, Shifeng [1 ]
Zhou, Jinghao [1 ]
Prado, Karl [1 ]
D'Souza, Warren [1 ]
Yi, Byongyong [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Sch Med, Baltimore, MD 21043 USA
关键词
BEAM COMPUTED-TOMOGRAPHY; CBCT; HEAD; FEASIBILITY; STRATEGY; VOLUME; IMRT;
D O I
10.1016/j.prro.2018.08.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study aimed to develop action levels for replanning to accommodate dosimetric variations resulting from anatomic changes during the course of treatments, using daily cone beam computed tomography (CBCT). Methods and materials: Daily or weekly CBCT images of 20 patients (10 head and neck, 5 lung, and 5 prostate cancers) who underwent resimulation per physicians' clinical decisions, mainly from the comparison of CBCT scans, were used to determine action levels. The first CBCT image acquired before the first treatment was used as the reference image to rule out effects of dose inaccuracy from the CBCT. The Pearson correlation of clinical target volume (CTV) was used as a parameter of anatomic variation. Parameters for action levels on dose and anatomic variation were deduced by comparing the parameters and clinical decisions made for replanning. A software tool was developed to automatically perform all procedures, including dose calculations, using the CBCT and plan evaluations. Results: Replans were clinically decided based on either significant dose or anatomic changes in 13 cases. The 7 cases that did not require replanning showed dose differences <5%, and the Pearson correlation of the CTV was >75% for all fractions. A difference in planning target volume dose >5% or a difference in the image correlation coefficient of the CTV <0.75 proved to be indicators for replanning. Once the results of the CBCT plan met the replanning criteria, the software tool automatically alerted the attending physician and physicist by both e-mail and pager so that the case could be examined closely. Conclusions: Our study shows that a dose difference of 5% and/or anatomy variation at 0.75 Pearson correlations are practical action levels on dose and anatomic variation for replanning for the given data sets. (C) 2018 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 14 条
  • [1] Treatment Dose Evaluation of IGRT and Adaptive Plan Modifications for Head-and-Neck Cancer Radiation Therapy
    Yang, K.
    Liang, J.
    Zhuang, L.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S695 - S696
  • [2] Evaluation of on- and offline strategies in adaptive radiation therapy using numerical simulation of organ motion and deformation.
    Rehbinder, H.
    Forsgren, C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S218 - S218
  • [3] Adaptive Liver Stereotactic Body Radiation Therapy: Automated Daily Plan Reoptimization Prevents Dose Delivery Degradation Caused by Anatomy Deformations
    Leinders, Suzanne M.
    Breedveld, Sebastiaan
    Romero, Alejandra Mendez
    Schaart, Dennis
    Seppenwoolde, Yvette
    Heijmen, Ben J. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (05): : 1016 - 1021
  • [4] Image-Guided Adaptive Radiation Therapy with anatomic imaging and dose verification in head and neck cancer using kV CBCT
    Chan, Maria F.
    Song, Yulin
    Burman, Chandra
    Hu, Yu-Chi
    Sim, Sang E.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 151 - 166
  • [5] Preliminary Results of Concurrent Chemotherapy and Radiation Therapy using High-dose-rate Brachytherapy for Cervical Cancer
    Lee, Kyung-Ja
    Lee, Jihye
    Lee, Rena
    Suh, Hyunsuk
    RADIATION ONCOLOGY JOURNAL, 2006, 24 (03): : 171 - 178
  • [6] The Feasibility of Using Daily Online CT Image Evaluation as an Indication to Trigger Adaptive Radiation Therapy for Esophageal Cancer
    Liu, Y.
    Zhu, Y.
    Chen, M.
    Jiang, H.
    Mo, Z.
    Li, H.
    Jia, L.
    Peng, Y.
    Deng, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E161 - E161
  • [7] Dose Escalation for Pancreas SBRT: Potential and Limitations of using Daily Online Adaptive Radiation Therapy and an Iterative Isotoxicity Automated Planning Approach
    Rhee, Dong Joo
    Beddar, Sam
    Jaoude, Joseph Abi
    Sawakuchi, Gabriel
    Martin, Rachael
    Perles, Luis
    Yu, Cenji
    He, Yulun
    Court, Laurence E.
    Ludmir, Ethan B.
    Koong, Albert C.
    Das, Prajnan
    Koay, Eugene J.
    Taniguichi, Cullen
    Niedzielski, Joshua S.
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (04)
  • [8] Preliminary evaluation of low-grade toxicity with conformal radiation therapy for prostate cancer on RTOG 9406 dose levels I and II
    Michalski, JM
    Winter, K
    Purdy, JA
    Wilder, RB
    Perez, CA
    Roach, M
    Parliament, MB
    Pollack, A
    Markoe, AM
    Harms, W
    Sandler, HM
    Cox, JD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 192 - 198
  • [9] Who Needs Adaptive Radiation -Therapy When You Can Do Internal Anatomy Positioning?: A Review of Daily Cone Beam Computed Tomography (CBCT) Scans to Analyze Geometric Dose Variation Due to Daily Rectal Variation and Distension in Postprostatectomy Radiation
    Elliott, D. A.
    Tanyi, J.
    Merz, B.
    Nabavizadeh, N.
    Hung, A. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S174 - S175
  • [10] Quantitative Evaluation of the Benefit of Fiducial Image-Guidance for Prostate Cancer Intensity Modulated Radiation Therapy using Daily Dose Volume Histogram Analysis
    Kasaova, L.
    Sirak, I.
    Jansa, J.
    Paluska, P.
    Petera, J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (01) : 47 - 55