A new ambulatory urodynamics monitoring system of measuring the abdominal pressure using the bio-impedance method

被引:0
|
作者
Kim, D. W. [2 ]
Kim, K. S. [1 ]
An, Y. S. [1 ]
Seo, J. H. [2 ,3 ]
Song, C. G. [1 ]
机构
[1] Chonbuk Natl Univ, Sch Elect & Informat Engn, 664-14 lga Deokjin Dong, Jeonju, South Korea
[2] Yonsei Univ Coll Med, Dept Med Engn, Seoul, South Korea
[3] Chonbuk Natl Univ, Dept Rehabil Med, Sch Med, Jeonju, South Korea
关键词
ambulatory urodynamics monitoring; detrusor pressure; bio-impedance; EMG activity; natural filling;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The conventional urodynamic monitoring is performed by filling artificially the bladder with saline. It is difficult to evaluate the physiological functions of the storage and voiding of the bladder. In this study, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by bio-impedance changes and EMG activity. The system was evaluated in 10 patients. As the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased as compared to those observed during resting. The correlation coefficient was 0.72 for the "weak" contraction, 0.96 for strong contraction, 0.90 for stronger contraction, 0.84 for vigorous contraction and 0.78 for maximal contraction. Also, daily events such as coughing, sneezing and conversation, were sensitively monitored by observing the amplitude change of the bio-impedance signals. However, the EMG signals could not be used to detect these events, therefore, bio-impedance method is a more useful tool to measure the changes in the abdominal pressure noninvasively for urodynamic monitoring.
引用
收藏
页码:628 / +
页数:2
相关论文
共 50 条
  • [1] Optimum electrode selection to quantify abdominal pressure using bio-impedance method
    Kim, Keo-Sik
    An, Yang-Su
    Seo, Jeong-Hwan
    Song, Chu-Gyu
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON MULTISENSOR FUSION AND INTEGRATION FOR INTELLIGENT SYSTEMS, VOLS 1 AND 2, 2008, : 299 - +
  • [2] A New Method for Detection of Leg Movement using Bio-impedance
    Kim, K. S.
    Lee, S. O.
    Kim, S. C.
    Kim, D. W.
    Seo, J. H.
    Kim, K. S.
    Song, C. G.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3956 - +
  • [3] Design and Method of Ambulatory Urodynamics Monitoring System
    Kim, K. S.
    Lee, S. O.
    An, Y. S.
    Seo, J. H.
    Kim, K. S.
    Song, C. G.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 4054 - +
  • [4] A portable bio-impedance system for monitoring lung resistivity
    Zlochiver, S.
    Arad, M.
    Radai, M. M.
    Barak-Shinar, D.
    Krief, H.
    Engelman, T.
    Ben-Yehuda, R.
    Adunsky, A.
    Abboud, S.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2007, 29 (01) : 93 - 100
  • [5] Evaluation of a bio-impedance method for measuring human arm movement
    Kim, JC
    Kim, SC
    Nam, KC
    Ahn, SH
    Park, M
    Kim, DW
    [J]. YONSEI MEDICAL JOURNAL, 2002, 43 (05) : 637 - 643
  • [6] Monitoring Breathing Rate using Bio-impedance Technique
    Potdar, Shweta V.
    Panditrao, Anagha
    Khambete, Niranjan D.
    [J]. 2016 INTERNATIONAL CONFERENCE ON COMPUTING COMMUNICATION CONTROL AND AUTOMATION (ICCUBEA), 2016,
  • [7] A Non-invasive Radial Arterial Compliance Measuring Method using Bio-Impedance
    Tang, Xiaochen
    Jankovic, Matija
    Jafari, Roozbeh
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 2330 - 2334
  • [8] A Tetrapolar Bio-Impedance Sensing System for Gastrointestinal Tract Monitoring
    Kassanos, Panagiotis
    Ip, Henry M. D.
    Yang, Guang-Zhong
    [J]. 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2015,
  • [9] An new approach of ambulatory urodynamic system for measuring the abdominal pressure
    Song, Chul-Gyu
    Kim, Jong Chan
    Seo, Jeong-Hwan
    Kim, Keo-Sik
    An, Yang Soo
    [J]. MUE: 2007 INTERNATIONAL CONFERENCE ON MULTIMEDIA AND UBIQUITOUS ENGINEERING, PROCEEDINGS, 2007, : 114 - +
  • [10] Hydration Assessment Using the Bio-Impedance Analysis Method
    AlDisi, Reem
    Bader, Qamar
    Bermak, Amine
    [J]. SENSORS, 2022, 22 (17)