Fluorescence-Based Blood Coagulation Assay Device for Measuring Activated Partial Thromboplastin Time

被引:13
|
作者
Dudek, Magdalena M. [1 ]
Kent, Nigel [2 ]
Gustafsson, Kerstin M. [3 ]
Lindahl, Tomas L. [3 ]
Killard, Anthony J. [1 ,4 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Biomed Diagnost Inst, Dublin 9, Ireland
[2] Dublin Inst Technol, Sch Mech & Transport Engn, Dublin 1, Ireland
[3] Linkoping Univ, Dept Clin & Expt Med, S-58183 Linkoping, Sweden
[4] Univ W England, Dept Appl Sci, Bristol BS16 1QY, Avon, England
基金
爱尔兰科学基金会;
关键词
MEMBRANE GLYCOPROTEIN-IIB; SURFACE-PLASMON RESONANCE; WHOLE-BLOOD; HEPARIN-THERAPY; APTT REAGENTS; COMPLEX-FORMATION; FIBRINOGEN; SENSITIVITY; PLATELETS; INTEGRINS;
D O I
10.1021/ac102436v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of blood clotting time is important in a range of clinical applications such as assessing coagulation disorders and controlling the effect of various anticoagulant drug therapies. Clotting time tests essentially measure the onset of clot formation which results from the formation of fibrin fibers in the blood sample. However, such assays are inherently imprecise due to the highly variable nature of the clot formation process and the sample matrix. This work describes a clotting time measurement assay which uses a fluorescent probe to very precisely detect the onset of fibrin clot formation. It uses a microstructured surface which enhances the formation of multiple localized clot loci and which results in the abrupt redistribution of the fluorescent label at the onset of clot formation in both whole blood and plasma. This methodology was applied to the development of an activated partial thromboplastin time (aPTT) test in a lateral flow microfluidic platform and used to monitor the effect of heparin dosage where it showed linearity from 0 to 2 U/mL in spiked plasma samples (R-2=0.996, n = 3), correlation against gold standard coagulometry of 0.9986, and correlation against standard hospital aPTT in 32 patient samples of 0.78.
引用
收藏
页码:319 / 328
页数:10
相关论文
共 50 条
  • [1] ACTIVATED PARTIAL THROMBOPLASTIN TIME AND ACTIVATED COAGULATION TIME IN MONITORING HEPARINIZED CATS
    GREENE, CE
    MERIWETHER, E
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 1982, 43 (08) : 1473 - 1477
  • [2] Correlation of whole blood activated partial thromboplastin time and plasma activated partial thromboplastin time in haemodialysis patients
    Low, CL
    Eisele, G
    Bailie, GR
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (12) : 2523 - 2523
  • [3] STATISTICAL CORRELATION AND HEPARIN SENSITIVITY OF ACTIVATED PARTIAL THROMBOPLASTIN TIME, WHOLE-BLOOD COAGULATION TIME, AND AN AUTOMATED COAGULATION TIME
    SCHRIEVE.HG
    EPSTEIN, SE
    MINTZ, MD
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1973, 60 (03) : 323 - 329
  • [4] PATTERN RECOGNITION OF BLOOD SAMPLES WITH PROLONGED ACTIVATED PARTIAL THROMBOPLASTIN TIME BY AN AUTOMATED COAGULATION ANALYZER
    Ohsaka, A.
    Yamamoto, T.
    Ishii, K.
    Kuno, Y.
    Horii, T.
    [J]. HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 : 348 - 348
  • [5] COMPARATIVE EVALUATION OF REAGENTS FOR ACTIVATED PARTIAL THROMBOPLASTIN TIME IN ASSAY OF COAGULATION FACTOR-VIII AND IX
    GLYNN, MFX
    GRADY, M
    [J]. CANADIAN JOURNAL OF MEDICAL TECHNOLOGY, 1977, 39 (02): : 45 - 48
  • [6] EVALUATION OF ACTIVATED PARTIAL THROMBOPLASTIN TIME REAGENTS IN DETECTION OF BLOOD-COAGULATION FACTOR DEFICIENCIES
    COMPTON, JL
    RODMAN, NF
    [J]. FEDERATION PROCEEDINGS, 1983, 42 (04) : 1033 - 1033
  • [7] Activated partial thromboplastin time overestimates anti-coagulation in left ventricular assist device patients
    McIlvennan, Colleen K.
    Page, Robert L., II
    Ambardekar, Amrut V.
    Brieke, Andreas
    Lindenfeld, JoAnn
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (12): : 1312 - 1314
  • [8] AN EVALUATION OF PARTIAL THROMBOPLASTIN TIME IN DETECTION OF BLOOD COAGULATION DISORDERS
    WHETHAM, J
    [J]. CANADIAN JOURNAL OF MEDICAL TECHNOLOGY, 1966, 28 (03): : 81 - &
  • [9] ACTIVATED PARTIAL THROMBOPLASTIN TIME PERFORMED ON CAPILLARY BLOOD
    BOUMERFEG, M
    AUROUSSEAU, MH
    LEROUX, G
    LORTHOLARY, P
    [J]. NOUVELLE REVUE FRANCAISE D HEMATOLOGIE, 1989, 31 (05): : 359 - 361
  • [10] DEVELOPMENT OF AN AUTOMATED PHOTOMETRIC ACTIVATED PARTIAL THROMBOPLASTIN TIME ASSAY
    BARTL, K
    LILL, H
    BECKER, U
    WAHLEFELD, A
    [J]. THROMBOSIS AND HAEMOSTASIS, 1985, 54 (01) : 27 - 27