Validity of autorefraction after cataract surgery with multifocal ReZoom intraocular lens implantation

被引:37
|
作者
Munoz, Gonzalo
Albarran-Diego, Cesar
Sakla, Hani F.
机构
[1] Ctr Offalmolog Marques Sotelo, Refract Surg Dept, Valencia 46002, Spain
[2] Hosp NISA Valenc Mar, Valencia 46002, Spain
[3] VISSUM Inst Offalmolog, Alicante, Spain
来源
关键词
D O I
10.1016/j.jcrs.2007.05.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the clinical utility of spherocylindrical automated refraction (AR) compared with subjective manifest refraction (MR) after cataract surgery with implantation of ReZoom refractive multifocal intraocular lenses (IOLs) (Advanced Medical Optics, Inc.). SETTING: Private Practice. METHODS: This prospective nonrandomized interventional study consisted of 72 patients with bilateral cataract and a potential visual acuity of at least 20/40. Patients had bilateral nonsimultaneous cataract surgery and implantation of a ReZoom IOL. Manifest refraction was performed in all patients followed by 3 consecutive measurements using the Topcon KR-8000 autorefractor with non-dilated and dilated pupils. Assessment of repeatability of multiple consecutive ARs and comparison of the AR and MR using power vector analysis were performed at the 6-month follow-up. The main outcome measures were the correlation between AR and MR with sphere, spherical equivalent, and astigmatism as well as the repeatability of AR before and after dilation with phenylephrine 10%. RESULTS: Repeatability analysis showed that the initial nondilated AR was not significantly different from the mean of the 3 refractions for nondilated and dilated measurements. The mean difference between the initial AR and the MR was -0.84 +/- 0.62 diopters (D) for sphere (0), -1.00 +/- 0.61 D for spherical equivalent, and -0.06 +/- 0.19 D and -0.01 +/- 0.17 D, respectively, for J(0) and J(45), the 2 components of astigmatism. Linear regression of AR versus MR data showed poor correlation for sphere (R-2 = 0.4852) and spherical equivalent (R-2 = 0.5529), whereas the correlation for the 2 astigmatic components of vector analysis was excellent (J(0), R-2 = 0.8881; J(45), R-2 = 0.8640). Correlation was better when the MR residual refractive defect was higher. CONCLUSIONS: Although autorefraction showed excellent agreement with subjective refractive astigmatism, correlation with spherical values was poor, with a trend toward more negative values. Autorefraction after ReZoom IOL implantation can be used as a good starting point for subjective refraction of astigmatism; however, spherical values should be underestimated.
引用
收藏
页码:1573 / 1578
页数:6
相关论文
共 50 条
  • [1] Multifocal intraocular lens implantation in pediatric cataract surgery
    Jacobi, PC
    Dietlein, TS
    Konen, W
    [J]. OPHTHALMOLOGY, 2001, 108 (08) : 1375 - 1380
  • [2] Autorefraction after implantation of diffractive multifocal intraocular lenses
    Bissen-Miyajima, Hiroko
    Minami, Keiichiro
    Yoshino, Mami
    Nishimura, Mariko
    Oki, Shinchi
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04): : 553 - 556
  • [3] Visual Outcomes After Implantation of a Segmental Refractive Multifocal Intraocular Lens Following Cataract Surgery
    Kohnen, Thomas
    Hemkeppler, Eva
    Herzog, Michael
    Schoenbrunn, Sabrina
    Delorenzo, Nina
    Petermann, Kerstin
    Boehm, Myriam
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 191 : 156 - 165
  • [4] Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation
    Visser, Nienke
    Nuijts, Rudy M. M. A.
    de Vries, Niels E.
    Bauer, Noel J. C.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11): : 2034 - 2042
  • [5] Visual and optical performance with the ReZoom multifocal intraocular lens
    Munoz, Gonzalo
    Albarran-Diego, Cesar
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (03) : 356 - 362
  • [6] Multifocal intraocular lens implantation in patients with traumatic cataract
    Jacobi, PC
    Dietlein, TS
    Lueke, C
    Jacobi, FK
    [J]. OPHTHALMOLOGY, 2003, 110 (03) : 531 - 538
  • [7] Vector analysis of astigmatic changes after cataract surgery with implantation of a new toric multifocal intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Tomas, Javier
    Plaza, Ana B.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07): : 1217 - 1229
  • [8] Clinical outcomes after cataract surgery with implantation of the Tecnis ZMB00 multifocal intraocular lens
    Lubinski, Wojciech
    Gronkowska-Serafin, Jolanta
    Podboraczynska-Jodko, Karolina
    [J]. MEDICAL SCIENCE MONITOR, 2014, 20 : 1220 - 1226
  • [10] Secondary intraocular lens implantation after cataract surgery in children
    Biglan, AW
    Cheng, KP
    Davis, JS
    Gerontis, CC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (02) : 224 - 234