Novel secondary standard for calibration of dynamic pressure sensors

被引:0
|
作者
Sander, Christian [1 ]
Aspiala, Markus [2 ]
Hogstrom, Richard [2 ]
机构
[1] Testo Ind Serv GmbH, Metrol, Kirchzarten, Germany
[2] VTT Tech Res Ctr Finland Ltd, MIKES Metrol, Espoo, Finland
关键词
Dynamic measurements; dynamic pressure; secondary pressure standard;
D O I
10.1515/teme-2022-0011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent research activities in dynamic pressure metrology have been mainly focusing on the development of primary standards like the shock tube or drop-weight apparatus to establish traceability to SI. However, these calibration facilities require a high level of expertise leading to elaborate and time-consuming calibrations. The development of secondary calibrators, based on the reference sensor principle, offering efficient and cost-effective calibrations is essential to meet the needs for industry and to disseminate the dynamic pressure quantity to a wide end-user community. This paper reports a novel secondary calibrator for dynamic pressure measurements up to 300 bar with an expanded uncertainty of about 3.0 %. A heating option enable calibrations at elevated temperatures up to 200 degrees C making it an ideal solution for convenient calibrations of dynamic pressure transducers used for measurement in internal combustion engine applications.
引用
收藏
页码:721 / 728
页数:8
相关论文
共 50 条
  • [1] Neues Sekundärnormal für die Kalibrierung von dynamischen Drucksensoren; [Novel secondary standard for calibration of dynamic pressure sensors]
    Sander C.
    Aspiala M.
    Högström R.
    Technisches Messen, 2022, 89 (10): : 721 - 728
  • [2] DYNAMIC CALIBRATION OF PRESSURE SENSORS BY PERIODICAL STEPS
    LOPEZ, J
    RECHERCHE AEROSPATIALE, 1970, 136 (03): : 175 - &
  • [3] DYNAMIC CALIBRATION OF PRESSURE SENSORS BY PERIODICAL STEPS
    LOPEZ, J
    HUMIERES, C
    MESURES REGULATION AUTOMATISME, 1972, 37 (03): : 87 - &
  • [4] Pressure Sensors: Working Principles of Static and Dynamic Calibration
    Pereira, Jose Dias
    SENSORS, 2024, 24 (02)
  • [5] Dynamic calibration of low range silicon pressure sensors
    Zakrzewski, J
    Wróbel, K
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 493 - 496
  • [6] Analyzing Frequency Response of Differential Pressure Sensors by Dynamic Pressure Calibration
    Kober, Timo
    Sindlinger, Stefan
    Werthschuetzky, Roland
    TM-TECHNISCHES MESSEN, 2010, 77 (02) : 83 - 88
  • [7] Dynamic Pressure Calibration of Pressure Sensors Using Liquid Step Pressure Generator
    Wang, Shenghung
    Han, Leelong
    Tsung, Tsing Tshih
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 : 8 - 12
  • [8] Dynamic modeling of liquid impulse pressure generator for calibration of pressure sensors
    Yang, Jun
    Fan, Shangchun
    Li, Bo
    Huang, Riheng
    Shi, Yusong
    Shi, Bo
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 : 120 - 131
  • [9] Dynamic calibration of low-range silicon pressure sensors
    Zakrzewski, J
    Wróbel, K
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (06) : 1358 - 1362
  • [10] Towards a shock tube method for the dynamic calibration of pressure sensors
    Downes, Stephen
    Knott, Andy
    Robinson, Ian
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2023):