Use of an Amplatz goose neck snare as a target for collateral neck vein dialysis catheter placement

被引:5
|
作者
Hagen, P [1 ]
Yang, JJ [1 ]
Saibil, EA [1 ]
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
关键词
catheters and catheterization; central access; dialysis; jugular vein; thrombosis;
D O I
10.1016/S1051-0443(07)61889-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors describe a technique for insertion of a hemodialysis catheter when the usual large neck veins are difficult to access. The essence of the procedure is the use of the Amplatz Goose Neck snare as a fluoroscopic target. The snare is used in its conventional mode to grasp the introduction wire. The dialysis line then can be placed in its usual fashion.
引用
收藏
页码:493 / 495
页数:3
相关论文
共 50 条
  • [1] Re: Use of an amplatz goose neck snare as a target for collateral neck vein dialysis catheter placement
    Funaki, B
    Zaleski, GX
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (10) : 1235 - 1235
  • [2] Re: Use of an amplatz gooseneck snare as a target for collateral neck vein dialysis catheter placement
    Braun, SD
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (02) : 216 - 216
  • [3] REMOVAL OF A RUPTURED ANGIOPLASTY BALLOON CATHETER WITH USE OF A NITINOL GOOSE NECK SNARE
    KIRSCH, MJ
    ELLWOOD, RA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (04) : 537 - 538
  • [4] Percutaneous transcatheter retrieval of intracardiac central venous catheter fragments in two infants using Amplatz Goose Neck snare
    Tutar, Ercan
    Aypar, Ebru
    Atalay, Semra
    Yavuz, Guelsan
    Dogu, Figen
    TURKISH JOURNAL OF PEDIATRICS, 2009, 51 (05) : 519 - 523
  • [5] Retrieval of entrapped coronary balloon catheter with Goose Neck snare
    Aikawa, Tadao
    Funayama, Naohiro
    Sunaga, Daisuke
    Minamino, Tohru
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 61 : 116 - 117
  • [6] Removal of a fractured retention wire of an Accufix ''J'' pacemaker lead with an Amplatz Goose Neck snare
    Saibil, EA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (03) : 367 - 369
  • [7] Comparison of the Texan foreign body retrieval device and the Amplatz goose neck snare in vivo and in vitro
    Kónya, A
    Choi, BG
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (04) : 693 - 702
  • [8] Goose Neck Snare for LV Lead Placement in Difficult Venous Anatomy
    Worley, Seth J.
    Gohn, Douglas C.
    Pulliam, Robert W.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12): : 1577 - 1581
  • [9] Usefulness of the goose neck snare for holding the guiding catheter for carotid artery stenting
    Uda, Takehiro
    Murata, Keiji
    Ichinose, Tsutomu
    Kusakabe, Taro
    Sakaguchi, Masakazu
    NEUROLOGICAL SURGERY, 2007, 35 (07): : 673 - 676
  • [10] Complication of the Percutaneous Retrieval of a Catheter Fragment Using a Triple Loop Goose Neck Snare
    Revilla Calavia, A.
    San Norberto Garcia, E. M.
    Ibanez Marana, M. A.
    Gutierrez Alonso, V.
    Vaquero Puerta, C.
    ANGIOLOGIA, 2011, 63 (03): : 143 - 144