Recent progress on the development of new divertor high heat flux components in JAERI is presented in this paper, Small-scale divertor mock-up was tested in PBEF (Particle Beam Engineering Facility). The mock-up has armor tiles made of 3D carbon-fiber-reinforced carbon composite(CFC) brazed onto a cooling tube made of dispersion-strengthened copper (DSCu) with a silver-free material. In the thermal cycling experiment, the mock-up could survive from the cyclic thermal load of 20 MW/m(2). In addition, the divertor mock-up with CVD-W armors also could survive from the cyclic thermal load of 5 MW/m(2) for 1000 cycles. For the development of real-scale divertor mock-ups, the real-scale vertical target mock-ups were successfully developed and tested. The armor tiles were made of unidirectional CFC and the cooling tube was made of DSCu, At a heat flux of 20 MW/m(2), the mock-up with DSCu cooling tube could withstand 1,000 thermal cycles without any-evidence of thermal fatigue of the cooling tube.
机构:
Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, JapanJapan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, Japan
Araki, M
Kitamura, K
论文数: 0引用数: 0
h-index: 0
机构:Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, Japan
Kitamura, K
Urata, K
论文数: 0引用数: 0
h-index: 0
机构:Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, Japan
Urata, K
Suzuki, S
论文数: 0引用数: 0
h-index: 0
机构:Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 31101, Japan