A Comparison of 4D Cone-Beam CT Algorithms for Slowly Rotating Scanners

被引:0
|
作者
Bergner, Frank [1 ]
Berkus, Timo [2 ]
Oelhafen, Markus [2 ]
Kunz, Patrik [2 ]
Pan, Tinsu [3 ]
Kachelriess, Marc [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, Henkestr 91, D-91052 Erlangen, Germany
[2] Varian Med Syst, CH-5405 Baden, Switzerland
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
Cone-beam CT CBCT; 4-D reconstruction; PICCS; TV; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; ART;
D O I
10.1109/NSSMIC.2009.5401884
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The study compares several algorithms for the 4D reconstruction of cone-beam computed tomography (CBCT) data that were recently proposed and which can be used from slowly rotating devices. In our case the imaging units are mounted to linear particle accelerators (LINAC). The algorithms are the conventional phase correlated reconstruction (PC), the McKinnon/Bates-Algorithm, the prior image constrained compressed sensing (PICCS) algorithm, the total-variation minimization (TV) algorithm, and our auto-adaptive phase-correlation (AAPC) algorithm. For each algorithm the same motion-affected rawdata are used and the reconstruction results compared to each other regarding their noise and artifact levels, as well as temporal resolution, and computational complexity and convergence. These criteria result in a discussion of the advantages and disadvantages of each algorithm. The temporal resolution is best in the algorithms which exclusively use data from a single motion phase only. The iterative algorithms show lower noise and artifact levels but are computationally complex and therefore may have a limited usage in the clinical application. Algorithms which include image enhancements beside a faster reconstruction represent a suitable trade-off for the clinical workflow.
引用
收藏
页码:3764 / +
页数:2
相关论文
共 50 条
  • [1] An investigation of 4D cone-beam CT algorithms for slowly rotating scanners
    Bergner, Frank
    Berkus, Timo
    Oelhafen, Markus
    Kunz, Patrik
    Pan, Tinsu
    Grimmer, Rainer
    Ritschl, Ludwig
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2010, 37 (09) : 5044 - 5053
  • [2] Actively triggered 4d cone-beam CT acquisition
    Fast, Martin F.
    Wisotzky, Eric
    Oelfke, Uwe
    Nill, Simeon
    [J]. MEDICAL PHYSICS, 2013, 40 (09)
  • [3] Iterative volume of interest based 4D cone-beam CT
    Martin, Rachael
    Ahmad, Moiz
    Hugo, Geoffrey
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2017, 44 (12) : 6515 - 6528
  • [4] Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy
    Li, Tianfang
    Xing, Lei
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1211 - 1219
  • [5] Directional Interpolation for Motion Weighted 4D Cone-Beam CT Reconstruction
    Zhang, Hua
    Sonke, Jan-Jakob
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 181 - 188
  • [6] 4D cone-beam CT (CBCT) using an on-board imager
    Li, T.
    Xing, L.
    Munro, P.
    Yang, Y.
    Loo, B.
    Koong, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2234 - 2234
  • [7] Fast 4D cone-beam CT from 60 s acquisitions
    Hansen, David C.
    Sorensen, Thomas Sangild
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 5 : 69 - 75
  • [8] Individualizing 4D cone-beam CT (CBCT) acquisition protocol for external beam radiotherapy
    Mao, W.
    Li, T.
    Munro, P.
    Chao, M.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S146 - S147
  • [9] Comparison of two cone-beam CT scanners dedicated to small animal research
    Cody, D
    Ross, W
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1322 - 1322
  • [10] Adaptive 4D cone beam CT
    Lu, J.
    Zhu, R.
    Munro, P.
    Jeung, A.
    Mostafave, H.
    Chi, P.
    Balter, P.
    Guerrero, T.
    Mohan, R.
    Pan, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S609 - S609