Wavelength dispersive X-ray fluorescence analysis using fundamental parameter approach of Catha edulis and other related plant samples

被引:23
|
作者
Shaltout, Abdallah A. [1 ,2 ]
Moharram, Mohammed A. [2 ]
Mostafa, Nasser Y. [3 ]
机构
[1] Taif Univ, Fac Sci, Dept Phys, At Taif 21974, Saudi Arabia
[2] Natl Res Ctr, Div Phys, Dept Spect, Cairo 12622, Egypt
[3] Suez Canal Univ, Fac Sci, Dept Chem, Ismailia, Egypt
关键词
WDXRF; Standard-less analysis; Catha edulis; Differential thermal analysis; INDUCED BREAKDOWN SPECTROSCOPY; HYDROXYAPATITE; SPECTROMETRY; XRF;
D O I
10.1016/j.sab.2012.01.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work is the first attempt to quantify trace elements in the Catha edulis plant (Khat) with a fundamental parameter approach. C. edulis is a famous drug plant in east Africa and Arabian Peninsula. We have previously confirmed that hydroxyapatite represents one of the main inorganic compounds in the leaves and stalks of C. edulis. Comparable plant leaves from basil, mint and green tea were included in the present investigation as well as trifolium leaves were included as a non-related plant. The elemental analyses of the plants were done by Wavelength Dispersive X-Ray Fluorescence (WDXRF) spectroscopy. Standard-less quantitative WDXRF analysis was carried out based on the fundamental parameter approaches. According to the standard-less analysis algorithms, there is an essential need for an accurate determination of the amount of organic material in the sample. A new approach, based on the differential thermal analysis, was successfully used for the organic material determination. The obtained results based on this approach were in a good agreement with the commonly used methods. Depending on the developed method, quantitative analysis results of eighteen elements including; Al, Br, Ca, Cl, Cu, Fe, K, Na, Ni, Mg, Mn, P, Rb, S, Si, Sr, Ti and Zn were obtained for each plant. The results of the certified reference materials of green tea (NCSZC73014, China National Analysis Center for Iron and Steel, Beijing, China) confirmed the validity of the proposed method. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 50 条
  • [1] Effect of sample preparation procedure on standardless wavelength dispersive X-ray fluorescence analysis of plant samples
    Orlic, Jovana
    Grzetic, Ivan
    Ilijevic, Konstantin
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 184
  • [2] WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE ANALYSIS USING SYNCHROTRON RADIATION
    Ohashi, Kazutaka
    Iide, Atsuo
    Gohshi, Yohichi
    ANALYTICAL SCIENCES, 1991, 7 : 361 - 364
  • [3] Application of Wavelength Dispersive X-Ray Fluorescence Spectrometry to Biological Samples
    Singh, Vivek K.
    Rai, Pradeep K.
    Pathak, Ashok K.
    Tripathi, Durgesh K.
    Singh, Subhash C.
    Singh, Jagdish P.
    SPECTROSCOPY, 2018, : 28 - 34
  • [4] Multielement analysis of soil and plant species using wavelength-dispersive X-ray fluorescence spectrometry
    Krishna, Keshav A.
    Mohan, Rama K.
    Dasaram, B.
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2013, 90 (11) : 2081 - 2087
  • [5] Artificial cellulose standards as calibration standards for wavelength-dispersive X-ray fluorescence analysis of elements in plant samples
    Orlic, Jovana
    Grzetic, Ivan
    Goessler, Walter
    Braeuer, Simone
    Caslavsky, Josef
    Porizka, Jaromir
    Ilijevic, Konstantin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 502 : 106 - 117
  • [6] Application of fundamental parameter approach using integrated backscattering intensity for X-ray fluorescence analysis
    Jin, Hak-Son
    Ri, Chol
    Jong, Yon-Song
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (05):
  • [7] Application of fundamental parameter approach using integrated backscattering intensity for X-ray fluorescence analysis
    Hak-Son Jin
    Chol Ri
    Yon-Song Jong
    Applied Physics A, 2020, 126
  • [8] Wavelength Dispersive X-ray Fluorescence Imaging
    Tsuji, Kouichi
    Ohmori, Takashi
    Yamaguchi, Makoto
    ANALYTICAL CHEMISTRY, 2011, 83 (16) : 6389 - 6394
  • [9] Application of Wavelength-Dispersive X-Ray Fluorescence Spectrometry to Biological Samples
    Singh, Vivek K.
    Rai, Pradeep K.
    Pathak, Ashok K.
    Tripathi, Durgesh K.
    Singh, Subhash C.
    Singh, Jagdish P.
    SPECTROSCOPY, 2017, 32 (07) : 41 - 47
  • [10] Effectiveness of activated carbon disk for the analysis of iodine in water samples using wavelength dispersive X-ray fluorescence spectrometry
    Lee, Junseok
    An, Jinsung
    Kim, Joo-Ae
    Yoon, Hye-On
    CHEMOSPHERE, 2016, 142 : 72 - 76