Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adults

被引:246
|
作者
Wilken, Jason M. [1 ]
Rodriguez, Kelly M. [1 ]
Brawner, Melissa [1 ]
Darter, Benjamin J. [1 ]
机构
[1] Brooke Army Med Ctr, Ctr Intrepid, Dept Orthoped & Rehabil, Ft Sam Houston, TX 78234 USA
关键词
Reliability; Minimal Detectable Change; Intraclass Correlation Coefficient; Gait analysis; LIMB 3-DIMENSIONAL KINEMATICS; RETEST RELIABILITY; WALKING; REPEATABILITY; CHILDREN; PARAMETERS; SPEED;
D O I
10.1016/j.gaitpost.2011.09.105
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Computerized assessment of gait is commonly used in both research and clinical settings to quantify gait mechanics and detect change in performance. Minimal Detectable Change values have only recently been reported, are only available for patient populations, and in many cases exceed 10 degrees. Twenty nine healthy individuals underwent two biomechanical gait assessments separated by 5.6 (SD 2.2) days, with two raters for each session. All subjects walked at a self selected pace and three controlled velocities. ICC. SEM and MDC for kinematic and kinetic measures were calculated for interrater-intrasession, intrarater-intersession and interrater-intersession. ICC values were in the good to excellent range (r > 0.75) for all kinematic and kinetic variables and all comparisons. M DC values were lower than previously published data for all similar comparisons. The results of the current study suggest that reliability is good to excellent across a range of controlled walking velocities and the introduction of a second rater does not appreciably impact ICC or MDC values. In young healthy adults changes in gait kinematics of greater than approximately 50 can be identified when comparing between sessions. Published by Elsevier B.V.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 50 条
  • [1] Reliability and minimal detectable change of gait kinematics in people who are hypermobile
    Bates, Alexander V.
    McGregor, Alison H.
    Alexander, Caroline M.
    GAIT & POSTURE, 2016, 44 : 37 - 42
  • [2] Within-assessor reliability and minimal detectable change of gait kinematics in a young obese demographic
    Horsak, Brian
    Pobatschnig, Barbara
    Baca, Arnold
    Greber-Platzer, Susanne
    Kreissl, Alexandra
    Nehrer, Stefan
    Wondrasch, Barbara
    Crevenna, Richard
    Keilani, Mohammad
    Kranzl, Andreas
    GAIT & POSTURE, 2017, 54 : 112 - 118
  • [3] Three dimensional multi-segmental trunk kinematics and kinetics during gait: Test-retest reliability and minimal detectable change
    Fernandes, Rita
    Armada-da-Silva, Paulo
    Pool-Goudaazward, Annelies
    Moniz-Pereira, Vera
    Veloso, Antonio P.
    GAIT & POSTURE, 2016, 46 : 18 - 25
  • [4] Asymmetric shoe height induces reactive changes in gait kinematics but not kinetics in healthy young adults
    Sato, Sumire D.
    Schlechter, Maia
    Price, Mark
    Hoogkamer, Wouter
    GAIT & POSTURE, 2023, 104 : 70 - 76
  • [5] Patellofemoral kinematics in healthy older adults during gait activities
    Kefala, Vasiliki
    Ali, Azhar A.
    Mannen, Erin M.
    Shelburne, Kevin B.
    HUMAN MOVEMENT SCIENCE, 2021, 75
  • [6] Does tester experience influence the reliability with which 3D gait kinematics are collected in healthy adults?
    Leigh, Ryan J.
    Pohl, Michael B.
    Ferber, Reed
    PHYSICAL THERAPY IN SPORT, 2014, 15 (02) : 112 - 116
  • [7] Effects of simulated crouch gait on foot kinematics and kinetics in healthy children
    Balzer, Julia
    Schelldorfer, Sarah
    Bauer, Christoph
    van der Linden, Marietta L.
    GAIT & POSTURE, 2013, 38 (04) : 619 - 624
  • [8] Test-retest reliability and minimal detectable change for measures of balance and gait in adults with cerebral palsy
    Levin, Ilana
    Lewek, Michael D.
    Giuliani, Carol
    Faldowski, Richard
    Thorpe, Deborah E.
    GAIT & POSTURE, 2019, 72 : 96 - 101
  • [9] Reliability and minimal detectable change of transcranial magnetic stimulation outcomes in healthy adults: A systematic review
    Beaulieu, Louis-David
    Flamand, Veronique H.
    Masse-Alarie, Hugo
    Schneider, Cyril
    BRAIN STIMULATION, 2017, 10 (02) : 196 - 213
  • [10] Three dimensional multi -segmental trunk kinematics and kinetics during gait: Test-retest reliability and minimal detectable change (vol 46, pg 18, 2016)
    Fernandes, Rita S.
    Armada-da-Silva, Paulo
    Pool-Goudzwaard, Annelies L.
    Moniz-Pereira, Vera
    Veloso, Antonio P.
    GAIT & POSTURE, 2016, 48 : 267 - 267