A new set up for multi-analyte sensing: At-line bio-process monitoring

被引:31
|
作者
Akin, Mehriban [1 ]
Prediger, Andreas [2 ]
Yuksel, Merve [1 ]
Hoepfner, Tim [2 ]
Demirkol, Dilek Odaci [1 ]
Beutel, Sascha [2 ]
Timur, Suna [1 ]
Scheper, Thomas [2 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
[2] Leibniz Univ Hannover, Inst Tech Chem, D-30167 Hannover, Germany
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 11期
关键词
Biosensor; In situ microscopy; Multi-analyte sensing; Yeast fermentation; IN-SITU MICROSCOPY; CELL-CONCENTRATION; GLUCOSE; BIOSENSOR; ETHANOL; INTERFERENCE; BIOREACTORS; LACTATE; OXYGEN;
D O I
10.1016/j.bios.2011.05.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A multi-analyte sensing device is described, for simultaneous at-line monitoring of glucose, ethanol, pO(2)-value and cell density. It consists of a dual biosensor, a modified microscope and a fiber optical pO(2)-sensor that are integrated into a flow analysis (FA) system. The biosensor is based on a conventional thin layer flow-through cell equipped with a gold (Au) dual electrode (serial configuration). The biosensors with no cross-talking were produced by modifying the electrochemical transducers. Each Au surface was initially modified by self-assembled monolayer (SAM) of cysteamine. Alcohol oxidase (AOx) and pyranose oxidase (PyOx) were immobilized each onto a gold surface by means of PAMAM (polyamidoamine) dendrimer via glutaraldehyde cross-linking. The responses for glucose and ethanol were linear up to 0.5 mM. The operational stability of the biosensors was very promising, after 11 h continuous operation, only 6.0% of the initial activity was lost. The potential of the described biosensor was demonstrated by parallel determination of ethanol and glucose in yeast fermentation process. Simultaneously the cell density of the culture was monitored with an in situ microscope (ISM), which was integrated into the FA system. Both the used in situ microscope and the image processing algorithm used for the analysis of the acquired image data are described. Furthermore the pO(2)-value was monitored using a fiber optical sensor, which was embedded in a flow cell. The multi-sensor device allows the at-line monitoring of several process values without the need for further sampling or time consuming offline measurements. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4532 / 4537
页数:6
相关论文
共 6 条
  • [1] Line-Monitoring, Hyperspectral Fluorescence Setup for Simultaneous Multi-Analyte Biosensing
    Liu, Zhiyi
    Shi, Heng
    Liu, Le
    Deng, Sunan
    Ji, Yanhong
    Ma, Suihua
    Ma, Hui
    He, Yonghong
    SENSORS, 2011, 11 (11) : 10038 - 10047
  • [2] A multi-analyte panel for non-invasive pharmacokinetic monitoring of second-line anti-tuberculosis drugs
    Gerona, Roy
    Wen, Anita
    Koss, Catherine
    Bacchetti, Peter
    Gandhi, Monica
    Metcalfe, John
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2016, 20 (07) : 991 - 992
  • [3] Bio-inspired uniform flow microfluidic sensor platform for multi-analyte sensing: a simulation-based outflow and injection study
    Gharpure, Pradnya
    Veeralingam, Sushmitha
    Badhulika, Sushmee
    MICROFLUIDICS AND NANOFLUIDICS, 2021, 25 (10)
  • [4] Bio-inspired uniform flow microfluidic sensor platform for multi-analyte sensing: a simulation-based outflow and injection study
    Pradnya Gharpure
    Sushmitha Veeralingam
    Sushmee Badhulika
    Microfluidics and Nanofluidics, 2021, 25
  • [5] Multi-analyte fluorescence sensing based on a post-synthetically functionalized two-dimensional Zn-MOF nanosheets featuring excited-state proton transfer process
    Yin, Shu-Hui
    Lan, Bi-Liu
    Yang, Ya-Li
    Tong, Yu-Qing
    Feng, Yan-Fang
    Zhang, Zhong
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2024, 657 : 880 - 892
  • [6] Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy
    Cho, M.
    Kim, T.
    Kang, S.
    Kim, D.
    Kim, K.
    Shin, D.
    Suh, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3392 - 3392