Influence of Natural Ventilation on Indoor PM2.5 Concentration in Residential Building

被引:0
|
作者
Zhao, Li [1 ]
Chen, Chao [2 ]
Cao, Guoqing [1 ]
机构
[1] China Acad Bldg Res, Inst Bldg Environm & Energy Efficiency, Beijing 100013, Peoples R China
[2] Beijing Univ Technol, Inst Architecture & Engn, Beijing 100022, Peoples R China
关键词
Residential building; Natural ventilation; PM2.5; Concentration; Outdoor air quality;
D O I
10.4028/www.scientific.net/AMM.675-677.194
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
According to PM2.5 contamination in residential building, a mathematical model is established about the effect of natural ventilation on PM2.5 pollution control based on calculus method. On the basis of some actual cases, such as indoor smoking and cleaning, indoor PM2.5 concentration is calculated for different air change rate and outdoor air quality. The concept of critical ventilation rate is provided. The conclusion of the paper provides some advice on natural ventilation and indoor life behavior.
引用
收藏
页码:194 / +
页数:2
相关论文
共 50 条
  • [1] Influence of natural ventilation rate on indoor PM2.5 deposition
    Liu, Cong
    Yang, Jiayu
    Ji, Siyu
    Lu, Yuxin
    Wu, Peichan
    Chen, Chun
    [J]. BUILDING AND ENVIRONMENT, 2018, 144 : 357 - 364
  • [2] PM2.5 and Ventilation in a Passive Residential Building
    Wang, Zhaojun
    Yu, Zhiyi
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3646 - 3653
  • [3] Residential building ventilation in situations with outdoor PM2.5 pollution
    Liu, Sumei
    Song, Rui
    Zhang, Tengfei
    [J]. BUILDING AND ENVIRONMENT, 2021, 202
  • [4] The Effectiveness of a Mechanical Ventilation System for Indoor PM2.5 in Residential Houses
    Shin, Dongho
    Kim, Younghun
    Hong, Kee-Jung
    Lee, Gunhee
    Park, Inyong
    Kim, Hak-Joon
    Kim, Sangwoo
    Hwang, Cheong-Ha
    Noh, Kwang-Chul
    Han, Bangwoo
    [J]. TOXICS, 2023, 11 (11)
  • [5] A mathematical model for predicting indoor PM2.5 concentration under different ventilation methods in residential buildings
    Xie, Wei
    Fan, Yuesheng
    Zhang, Xin
    Tian, Guoji
    Si, Pengfei
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2020, 41 (06): : 694 - 708
  • [6] Indoor and outdoor concentration of PM10, PM2.5 and PM1 in residential building and evaluation of negative air ions (NAIs) in indoor PM removal
    Nadali, Azam
    Arfaeinia, Hossein
    Asadgol, Zahra
    Fahiminia, Mohammad
    [J]. ENVIRONMENTAL POLLUTANTS AND BIOAVAILABILITY, 2020, 32 (01) : 47 - 55
  • [7] Assessment of indoor PM2.5 in different residential environments
    Yassin, Mohamed F.
    AlThaqeb, Bothaina E. Y.
    Al-Mutiri, Eman A. E.
    [J]. ATMOSPHERIC ENVIRONMENT, 2012, 56 : 65 - 68
  • [8] Indoor PM2.5 and building energy consumption in nine typical residential neighborhoods in Nanjing under different ventilation strategies caused by traffic-related PM2.5 dispersion
    Wang, Hanning
    Guo, Xin
    Yang, Junlu
    Gao, Zhi
    Zhang, Mingjie
    Xu, Fusuo
    [J]. Journal of Building Engineering, 2024, 95
  • [9] Impact of residential building regulations on reducing indoor exposures to outdoor PM2.5 in Toronto
    Zuraimi, M. S.
    Tan, Zhongchao
    [J]. BUILDING AND ENVIRONMENT, 2015, 89 : 336 - 344
  • [10] Influences of ambient air PM2.5 concentration and meteorological condition on the indoor PM2.5 concentrations in a residential apartment in Beijing using a new approach
    Han, Yang
    Qi, Meng
    Chen, Yilin
    Shen, Huizhong
    Liu, Jing
    Huang, Ye
    Chen, Han
    Liu, Wenxin
    Wang, Xilong
    Liu, Junfeng
    Xing, Baoshan
    Tao, Shu
    [J]. ENVIRONMENTAL POLLUTION, 2015, 205 : 307 - 314