Test-retest and Interrater Reliability of the Video Head Impulse Test in the Pediatric Population

被引:30
|
作者
Ross, Lynda Marie [1 ]
Helminski, Janet Odry [2 ]
机构
[1] Nova SE Univ, Dept Phys Therapy, Tampa, FL USA
[2] Midwestern Univ, Dept Phys Therapy, Downers Grove, IL 60515 USA
关键词
Children; Pediatric population; Reliability vHIT; Reliability video head impulse test; Vestibular function; Vestibular-ocular reflex; VOR; VESTIBULOOCULAR REFLEX; VESTIBULAR DEFICITS; CERVICAL-SPINE; OCULOGRAPHY; COMPENSATION; MECHANISMS; RESPONSES; ASYMMETRY; FREQUENCY; SYSTEM;
D O I
10.1097/MAO.0000000000001040
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Determine reliability of horizontal and vertical video head impulse test (vHIT) and effect of maturation on angular vestibular ocular reflex (AVOR) gain estimations and peak head velocities of individual canals in typically developing children and adolescents. Design: Reliability study. Setting: University research laboratory Subjects: Two normal adults mean age 51.5 +/- 0.5 years and 28 typically developing children and adolescents mean age 10 +/- 3.5 years (range, 4.33-17.25 years). Main Outcome Measures: Mean AVOR gain estimate and peak head impulse velocity for individual canals. Results: In adult sample, mean AVOR gain estimates were 1.00 to 1.04 for lateral and 1.07 to 1.13 for vertical canals. In pediatric sample, mean AVOR gain estimates were 1.00 to 1.04 for lateral and 1.03 to 1.08 vertical canals. Mean AVOR gain intrarater reliability scores (intraclass correlation coefficient [ICC] >= 0.821 <= 0.945) and interrater reliability scores (ICC >= 0.800 <= 0.971) had good consistency. For each canal, across each age group, the range of percentage of trials with peak head velocities greater than 100 degrees/s was 32 to 49% right lateral, 31 to 49% left lateral, 0 to 11% right anterior, 3 to 4% left anterior, 1 to 7% right posterior, and 2 to 8% left posterior. Children aged less than 12 years, required 10 to 49% more trials compared with adults to obtain five valid, filtered trials. Adolescents required a similar number of trials compared with adults. Conclusion: In pediatric population, vHIT is a reliable clinical test to quantify individual canal function using high velocity head impulses. With children, it was difficult to acquire head impulse velocities of greater than 100 degrees/s especially in the plane of the vertical canals. These higher head velocities are required to reveal asymmetry in compensatory eye movements.
引用
收藏
页码:558 / 563
页数:6
相关论文
共 50 条
  • [1] Normative Data and Test-Retest Reliability of the SYNAPSYS Video Head Impulse Test
    Murnane, Owen
    Mabrey, Heather
    Pearson, Amber
    Byrd, Stephanie
    Akin, Faith
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2014, 25 (03) : 244 - 252
  • [2] Test-Retest Reliability of Video Head Impulse Test in Healthy Individuals and Individuals with Dizziness
    Singh, Niraj Kumar
    Govindaswamy, Rajeshwari
    Jagadish, Nirmala
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2019, 30 (09) : 744 - 752
  • [3] Test-retest and interrater reliability of Barcelona test
    Serra-Mayoral, A.
    Pena-Casanova, J.
    [J]. NEUROLOGIA, 2006, 21 (06): : 277 - 281
  • [4] INTERRATER AND TEST-RETEST RELIABILITY OF 2 PEDIATRIC BALANCE TESTS
    ATWATER, SW
    CROWE, TK
    DEITZ, JC
    RICHARDSON, PK
    [J]. PHYSICAL THERAPY, 1990, 70 (02): : 79 - 87
  • [5] Test-Retest Reliability of the Grooved Pegboard Test in a Pediatric Medical Population
    David, C.
    Vasserman, M.
    Brooks, B.
    Macallister, W.
    [J]. ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2020, 35 (06) : 848 - 848
  • [6] An evaluation of the test-retest reliability of the functional head impulse test in healthy young adults
    Kirazli, Gulce
    Emekci, Tugba
    Inceoglu, Feyza
    Akmese, Pelin Pistav
    Celebisoy, Nese
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (12) : 5339 - 5343
  • [7] TEST-RETEST AND INTERRATER RELIABILITY OF A PROCESS SKILLS ASSESSMENT
    DOBLE, SE
    [J]. OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1991, 11 (01): : 8 - 23
  • [8] Test-Retest and Interrater Reliability of the Functional Movement Screen
    Shultz, Rebecca
    Anderson, Scott C.
    Matheson, Gordon O.
    Marcello, Brandon
    Besier, Thor
    [J]. JOURNAL OF ATHLETIC TRAINING, 2013, 48 (03) : 331 - 336
  • [9] Interrater and test-retest reliability of the Hand Assessment for Infants
    Ullenhag, Anna
    Ek, Linda
    Eliasson, Ann-Christin
    Krumlinde-Sundholm, Lena
    [J]. DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2021, 63 (12): : 1456 - 1461
  • [10] Interrater and test-retest reliability of a fixed condition Design Fluency Test
    Kingery, Lisle R.
    Schretlen, David J.
    Sateri, Sara
    Langley, Linda K.
    Marano, Nicole C.
    Meyer, Stephen M.