Diagnostic performance of radiologists with and without different CAD systems for mammography

被引:2
|
作者
Lauria, A [1 ]
Fantacci, ME [1 ]
Bottigli, U [1 ]
Delogu, P [1 ]
Fauci, F [1 ]
Golosio, B [1 ]
Indovina, PL [1 ]
Masala, GL [1 ]
Oliva, P [1 ]
Palmiero, R [1 ]
Raso, G [1 ]
Stumbo, S [1 ]
Tangaro, S [1 ]
机构
[1] Ist Nazl Fis Nucl, I-80126 Naples, Italy
关键词
Computer-Aided Detection; mammography; double reading; breast cancer;
D O I
10.1117/12.480079
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The purpose of this study is the evaluation of the variation of performance in terms of sensitivity and specificity of two radiologists with different experience in mammography, with and without the assistance of two different CAD systems. The CAD considered are SecondLook(TM) (CADx Medical Systems, Canada), and CALMA (Computer Assisted Library in MAmmography). The first is a commercial system, the other is the result of a a research project, supported by INFN (Istituto Nazionale di Fisica Nucleare, Italy); their characteristics have been already reported in literature. To compare, the results with and without these tools, a dataset composed by 70 images of patients with cancer (biopsy proven) and 120 images of healthy breasts (with a three years follow up) has been collected. All the images have been digitized and analysed by two CAD, then two radiologists with respectively 6 and 2 years of experience in mammography indipendently made their diagnosis without and with, the support of the two CAD systems. In this work sensitivity and specificity variation, the A, area under the ROC curve, are reported. The results show that the use of a CAD allows for a substantial increment in sensitivity and a less pronounced decrement in specificity. The extent of these effects depends on the experience of the readers and is comparable for the two CAD considered.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [1] Performance parameters for screening and diagnostic mammography: Specialist and general radiologists
    Sickles, EA
    Wolverton, DE
    Dee, KE
    [J]. RADIOLOGY, 2002, 224 (03) : 861 - 869
  • [2] Do Mammographic Technologists Affect Radiologists' Diagnostic Mammography Interpretative Performance?
    Henderson, Louise M.
    Benefield, Thad
    Bowling, J. Michael
    Durham, Danielle D.
    Marsh, Mary W.
    Schroeder, Bruce F.
    Yankaskas, Bonnie C.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (04) : 903 - 908
  • [3] Does diagnostic accuracy in mammography depend on radiologists' experience?
    Elmore, JG
    Wells, CK
    Howard, DH
    [J]. JOURNAL OF WOMENS HEALTH, 1998, 7 (04): : 443 - 449
  • [4] Performance assessment for radiologists interpreting screening mammography
    Woodard, D. B.
    Gelfand, A. E.
    Barlow, W. E.
    Elmore, J. G.
    [J]. STATISTICS IN MEDICINE, 2007, 26 (07) : 1532 - 1551
  • [5] Differences and similarities in false interpretations by AI CAD and radiologists in screening mammography
    Salim, Mattie
    Dembrower, Karin
    Eklund, Martin
    Smith, Kevin
    Strand, Fredrik
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1151):
  • [6] Performance parameters for screening and diagnostic mammography in a community practice: are there differences between specialists and general radiologists?
    Leung, Jessica W. T.
    Margolin, Frederick R.
    Dee, Katherine E.
    Jacobs, Richard P.
    Denny, Susan R.
    Schrumpf, John D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) : 236 - 241
  • [7] Positive Predictive Value of Mammography: Comparison of Interpretations of Screening and Diagnostic Images by the Same Radiologist and by Different Radiologists
    Halladay, Jacqueline R.
    Yankaskas, Bonnie C.
    Bowling, J. Michael
    Alexander, Camille
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 782 - 785
  • [8] Computer Aided Detection (CAD) Systems for Mammography and the Use of GRID in Medicine Cad for Mammography
    Lauria, Adele
    [J]. MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 161 - 173
  • [9] Computer-aided diagnosis (CAD) of screening mammography compared to diagnosis by radiologists
    Logan-Young, WW
    Bonaccio, E
    Destounis, SV
    DiNitto, P
    Zuley, ML
    Willison, K
    [J]. RADIOLOGY, 2001, 221 : 473 - 473
  • [10] Equalizing the Performance of Radiologists and Physician Extenders in Screening Mammography
    Hooley, Regina J.
    Durand, Melissa A.
    [J]. RADIOLOGY, 2023, 306 (01) : 110 - 111