Model predictive control of radiant slab systems with evaporative cooling sources

被引:70
|
作者
Feng, Jingjuan [1 ]
Chuang, Frank [2 ]
Borrelli, Francesco [2 ]
Bauman, Fred [3 ]
机构
[1] Univ Calif Berkeley, Dept Architecture, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Ctr Built Environm, Berkeley, CA 94720 USA
关键词
Radiant slab systems; Evaporative cooling; Model predictive control; Energy and comfort performance; Calibrated simulation; BUILDING SYSTEMS; ENERGY; PERFORMANCE; SIMULATION; MASS; LOAD;
D O I
10.1016/j.enbuild.2014.11.037
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Buildings that use radiant slab systems with evaporative cooling sources have shown to be energy efficient. However, control of the systems is challenging because of the slow response of the slab and the limited capacity of cooling sources. The objectives of this paper are to: (1) create a simplified dynamic model of radiant slab system for implementation in real-time model predictive controller (MPC); and (2) test the MPC energy and thermal comfort performance in a case study building. A calibrated EnergyPlus model of the building was developed as the testbed. The MPC is compared with the existing rule-based control method for a cooling season in a dry and hot climate. The results indicated that the MPC controller was able to maintain zone operative temperatures at EN 15251 Category II level more than 95% of the occupied hours for all zones, while with the rule-based method, only the core zone were maintained at this thermal comfort level. Compared to the rule-based method, MPC reduced the cooling tower energy consumption by 55% and pumping power consumption by 25%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 210
页数:12
相关论文
共 50 条
  • [1] Testing and demonstration of model predictive control applied to a radiant slab cooling system in a building test facility
    Pang, Xiufeng
    Duarte, Carlos
    Haves, Philip
    Chuang, Frank
    ENERGY AND BUILDINGS, 2018, 172 : 432 - 441
  • [2] Model predictive control for energy-efficient optimization of radiant ceiling cooling systems
    Chen, Qiong
    Li, Nan
    BUILDING AND ENVIRONMENT, 2021, 205
  • [3] Radiant Slab Cooling for Retail
    Doebber, Ian
    Moore, Mike
    Deru, Michael
    ASHRAE JOURNAL, 2010, 52 (12) : 28 - +
  • [4] A model predictive control strategy to optimize the performance of radiant floor heating and cooling systems in office buildings
    Joe, Jaewan
    Karava, Panagiota
    APPLIED ENERGY, 2019, 245 : 65 - 77
  • [5] Control biofouling in evaporative cooling systems
    Buecker, B
    Post, R
    CHEMICAL ENGINEERING PROGRESS, 1998, 94 (09) : 45 - 50
  • [6] Control biofouling in evaporative cooling systems
    UCB Films, Inc, Tecumseh, United States
    Chem Eng Prog, 9 (45-50):
  • [7] Analysis of Integrated Radiant Slab Heating and Cooling Systems for Residential Buildings
    Park, Benjamin
    Krarti, Moncef
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2016, 22 (01)
  • [8] Model Predictive Control for the Operation of Building Cooling Systems
    Ma, Yudong
    Borrelli, Francesco
    Hencey, Brandon
    Coffey, Brian
    Bengea, Sorin
    Haves, Philip
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2012, 20 (03) : 796 - 803
  • [9] Model Predictive Control for the Operation of Building Cooling Systems
    Ma, Yudong
    Borrelli, Francesco
    Hencey, Brandon
    Coffey, Brian
    Bengea, Sorin
    Haves, Philip
    2010 AMERICAN CONTROL CONFERENCE, 2010, : 5106 - 5111
  • [10] Indirect evaporative cooling combined with dehumidification in a MVHR system for radiant cooling
    Mariotti, Marco
    Moro, Lorenzo
    71ST CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION (ATI 2016), 2016, 101 : 448 - 455