Investigation of Voltammetric Behavior of 3-Nitro-Tyrosine and Tyrosine at Glassy Carbon and Carbon Paste Electrodes

被引:0
|
作者
Imanpor, S. [1 ]
Alizadeh, T. [2 ]
机构
[1] Chem & Chem Engn Res Ctr Iran, POB 14665-1513, Tehran, Iran
[2] Univ Tehran, Fac Chem, Univ Coll Sci, Dept Analyt Chem, POB 14155-6455, Tehran, Iran
来源
关键词
Nitro-tyrosine; Tyrosine; Carbon paste electrode; Simultaneous Determination; Electroxidation; MOLECULARLY IMPRINTED POLYMER; ELECTROCHEMICAL DETERMINATION; 3-NITROTYROSINE; NITROTYROSINE; SENSOR; ELECTROANALYSIS; FABRICATION; COMPOSITE;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Nitro-tyrosine is produced via tyrosine nitration by reactive nitrogen species such as peroxynitrite and NO2. Nitrotyrosine presence in the body is an indicator for cell damage and inflammation issue. Hence, the monitoring of this biomarker is an important task. Since nitro-tyrosine is produced from tyrosine, these two molecules are present concurrently in the real samples. In this work electrooxidation of nitro-tyrosine and tyrosine was checked on glassy carbon and carbon paste electrodes (CPE) utilizing cyclic voltammetry and differential pulse voltammetry methods. It was found that nitro-tyrosine creates an oxidation signal at the GC electrode, whereas, no significant oxidation peak was found for tyrosine in the GC electrode. In the case of CPE, However, both nitro-tyrosine and tyrosine showed oxidation peaks which were separated by about 0.1 V/Ag/AgCl. Applying DPV led to better resolution of oxidation peaks of tyrosine and nitro-tyrosine. Moreover, the separation of the peaks was improved when DPV was replaced with CV. Solution pH and the binder content of the carbon paste electrode were optimized in order to achieve maximum signal for both compounds. The calibration curves were established utilizing CPE and DPV techniques.
引用
收藏
页码:246 / 255
页数:10
相关论文
共 50 条
  • [1] Voltammetric Studies of 3-Nitro-tyrosine Electro-oxidation at Solid Electrodes and its Interaction with DNA
    Nascimento, Jose A. M.
    Nascimento, Maysa L.
    Mendes, Carlos H. S.
    Oliveira, Severino Carlos B.
    ELECTROANALYSIS, 2021, 33 (01) : 216 - 225
  • [2] Detection of 3-nitro-tyrosine in the cataractous lens
    Paik, DC
    Choi, S
    Merriam, JC
    Dillon, JP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U407 - U407
  • [3] Preconcentration and Voltammetric Determination of Nitro Compounds on Carbon-Paste Electrodes
    S. V. Sapel'nikova
    N. V. Kuz'mina
    V. N. Maistrenko
    F. Kh. Kudasheva
    Journal of Analytical Chemistry, 2002, 57 : 443 - 447
  • [4] Preconcentration and voltammetric determination of nitro compounds on carbon-paste electrodes
    Sapel'nikova, S.V.
    Kuz'mina, N.V.
    Majstrenko, V.N.
    Kudasheva, F.Kh.
    Zhurnal Analiticheskoj Khimii, 2002, 57 (05): : 532 - 538
  • [5] Preconcentration and voltammetric determination of nitro compounds on carbon-paste electrodes
    Sapel'nikova, SV
    Kuz'mina, NV
    Maistrenko, VN
    Kudasheva, FK
    JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (05) : 443 - 447
  • [6] Glassy carbon paste electrodes
    Wang, J
    Anik, Ü
    Mo, JW
    Lu, JM
    Kawde, AN
    Muck, A
    ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (04) : 203 - 208
  • [7] Redox reactions of ortho-tyrosine and 3-nitro-tyrosine: A comparative study with para-tyrosine
    Nascimento, Raphael F.
    Nascimento, Maysa L.
    Nascimento, Jose A. M.
    Santos, Hitala N. L.
    Araujo, Alex P.
    Oliveira, Severino Carlos B.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 854
  • [8] Single-wall carbon nanotube paste electrodes: a comparison with carbon paste, platinum and glassy carbon electrodes via cyclic voltammetric data
    Antiochia, R
    Lavagnini, I
    Magno, F
    Valentini, T
    Palleschi, G
    ELECTROANALYSIS, 2004, 16 (17) : 1451 - 1458
  • [9] A voltammetric comparison of the properties of carbon paste electrodes containing glassy carbon microparticles of various sizes
    Nemcova, Lenka
    Barek, Jiri
    Zima, Jiri
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 675 : 18 - 24
  • [10] Influence of anodic oxidation of glassy carbon surface on voltammetric behavior of Nafion®-coated glassy carbon electrodes
    Maruyama, J
    Abe, I
    ELECTROCHIMICA ACTA, 2001, 46 (22) : 3381 - 3386