Evaluation of lung tumor dose coverage in free-breathing treatment plans using respiration-correlated CT

被引:0
|
作者
Ford, E
Mageras, G
Yorke, E
机构
[1] Univ Washington, Seattle, WA 98195 USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
关键词
D O I
10.1118/1.1997561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We quantify the effect of respiration on 3D conformal radiotherapy of lung tumors in terms of dosimetric end‐points using respiration‐correlated CT scans (RCCT). Method and Materials: Six patients received RCCT scans (GE Advantage4D CT). Repeat slices were obtained at each couch position and retrospectively sorted according to respiratory phase using an external respiratory monitor. We generated simulated free‐breathing (FB) CT sets by assembling slices at different respiratory phases from the RCCT study. FB treatment plans similar to the clinical plan were created based on a 1.5 cm expansion of the gross tumor volume (GTV) in one patient and 1.0 cm in two other patients. Superposition‐convolution dose calculations (ADAC/Pinnacle system) were used. We applied the FB plan to the RCCT data sets at various respiratory phases and evaluated dose coverage of the GTV and clinical target volume (CTV=GTV+6mm). Results: Initial results are presented for an extreme situation: the patient with the largest tumor motion (2.3 cm, inferior/superior direction) and the start phase of the simulated FB scan chosen to have the tumor at its most superior position. The D99% values are: 1) FB plan: GTV 5833 cGy, CTV 5706 cGy. 2) FB plan applied to end‐inspiration: GTV 5828 cGy, CTV 5433 cGy. The GTV and CTV are only modestly underdosed at end‐inspiration (tumor most inferior), in this worst case scenario (FB plan based on a tumor at a superior position). Dosimetric indices at end‐expiration show less change. Preliminary studies on two other patients with smaller tumor excursions show similarly small dosimetric changes. Conclusion: Tumor coverage by free‐breathing based plans with standard margins changes only slightly with breathing phase in an extreme case. This study examines only respiratory motion and not interfractional tumor motion or setup error which also affect tumor dose coverage. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1922 / 1922
页数:1
相关论文
共 41 条
  • [1] Measurement of lung tumor motion using respiration-correlated CT
    Mageras, GS
    Pevsner, A
    Yorke, ED
    Rosenzweig, KE
    Ford, EC
    Hertanto, A
    Larson, SM
    Lovelock, DM
    Erdi, YE
    Nehmeh, SA
    Humm, JL
    Ling, CC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 933 - 941
  • [2] Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model
    Hertanto, Agung
    Zhang, Qinghui
    Hu, Yu-Chi
    Dzyubak, Oleksandr
    Rimner, Andreas
    Mageras, Gig S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3070 - 3079
  • [3] Reduction of Irregular Breathing Artifacts in Respiration-Correlated CT Images Using a Respiratory Motion Model
    Hertanto, A.
    Zhang, Q.
    Hu, Y.
    Rosenzweig, K.
    Mageras, G.
    MEDICAL PHYSICS, 2010, 37 (06) : 3460 - +
  • [4] Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images
    Pevsner, A
    Davis, B
    Joshi, S
    Hertanto, A
    Mechalakos, J
    Yorke, E
    Rosenzweig, K
    Nehmeh, S
    Erdi, YE
    Humm, JL
    Larson, S
    Ling, CC
    Mageras, GS
    MEDICAL PHYSICS, 2006, 33 (02) : 369 - 376
  • [5] Quantifying inter and intra-fraction tumor motion using respiration-correlated cone beam CT in lung stereotactic body radiotherapy (SBRT)
    Franks, K. N.
    Purdie, T. G.
    Bezjak, A.
    Moseley, D.
    Pearson, S.
    Jaffrayl, D. A.
    Bissonnette, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S489 - S490
  • [6] Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry
    D'Souza, WD
    Kwok, Y
    Deyoung, C
    Zacharapoulos, N
    Pepelea, M
    Klahr, P
    Yu, CX
    MEDICAL PHYSICS, 2005, 32 (12) : 3641 - 3649
  • [7] Image-guided radiotherapy for lung cancer: Respiration-correlated (Cone-Beam) CT to verify tumor position and motion characteristics during treatment delivery
    Damen, E
    Wolthaus, J
    Herk, MV
    Sonke, J
    Remeijer, P
    Zijp, L
    Belderbos, J
    Jaeger, KD
    Lebesque, J
    Boersma, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S198 - S198
  • [8] Impact of respiratory-correlated CT sorting algorithms on the choice of margin definition for free-breathing lung radiotherapy treatments
    Thengumpallil, Sheeba
    Germond, Jean-Francois
    Bourhis, Jean
    Bochud, Francois
    Moeckli, Raphael
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (03) : 438 - 443
  • [9] QUANTIFYING INTERFRACTION AND INTRAFRACTION TUMOR MOTION IN LUNG STEREOTACTIC BODY RADIOTHERAPY USING RESPIRATION-CORRELATED CONE BEAM COMPUTED TOMOGRAPHY
    Bissonnette, Jean-Pierre
    Franks, Kevin N.
    Purdie, Thomas G.
    Moseley, Douglas J.
    Sonke, Jan-Jakob
    Jaffray, David A.
    Dawson, Laura A.
    Bezjak, Andrea
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : 688 - 695
  • [10] Imaging of cardiac perfusion of free-breathing small animals using dynamic phase-correlated micro-CT
    Sawall, Stefan
    Kuntz, Jan
    Socher, Michaela
    Knaup, Michael
    Hess, Andreas
    Bartling, Soenke
    Kachelriess, Marc
    MEDICAL PHYSICS, 2012, 39 (12) : 7499 - 7506