A Localized Transient-Based Fault Location Scheme for Distribution Systems

被引:4
|
作者
Bayati, Navid [1 ]
Mortensen, Lasse Kappel [2 ]
Savaghebi, Mehdi [1 ]
Shaker, Hamid Reza [2 ]
机构
[1] Univ Southern Denmark, Ctr Ind Elect, Dept Mech & Elect Engn, DK-6400 Sonderborg, Denmark
[2] Univ Southern Denmark, Ctr Energy Informat, Maersk Mc Kinney Mller Inst, DK-5230 Odense, Denmark
关键词
distribution system; fault location; overcurrent relay; DISTRIBUTION NETWORK; FEEDER;
D O I
10.3390/s22072723
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many distribution systems have several branches with only one protection system at the upstream system. This characteristic degrades the performance of traditional fault location schemes. In this paper, a localized fault location method based on the transient behavior of fault currents by using local data is proposed. The proposed scheme uses only local current and the voltage of the upstream overcurrent relay as input data of the fault location scheme. The formulation considers fault resistance, loads, and different fault locations. Furthermore, due to the usage of transient fault current data, the proposed method locates the fault within several milliseconds with a suitable range of error. To validate the effectiveness of this method, field measurement data, obtained from a real distribution system in East Jutland, Denmark operated by Dinel A/S, are used, and extensive real-time simulations are performed. The results prove that the proposed method locates different types of faults within an appropriate time and error, which can improve the maintenance and reliability of distribution systems.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Impact of Distributed Generation on Transient-Based Fault Location Techniques in Distribution Networks
    Feizifar, Behnam
    Usta, Omer
    Haghifam, Mahmoud Reza
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2015, 10 (03) : 242 - 248
  • [2] Surge Compression for Improved Fault Location Accuracy in Full Transient-Based Methods
    Cozza, Andrea
    He, Shao-yin
    Xie, Yan-zhao
    IEEE SENSORS JOURNAL, 2021, 21 (02) : 995 - 1008
  • [3] Impact of Propagation Losses on Fault Location Accuracy in Full Transient-Based Methods
    Cozza, Andrea
    He, Shao-Yin
    Xie, Yan-Zhao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) : 383 - 396
  • [4] An Inverse Transient-Based Optimization Approach to Fault Examination in Water Distribution Networks
    Lin, Chao-Chih
    Yeh, Hund-Der
    WATER, 2019, 11 (06)
  • [5] A Wideband Fault Location Scheme for Active Distribution Systems
    Aboshady, F. M.
    Sumner, Mark
    Thomas, D. W. P.
    2018 7TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2018, : 891 - 896
  • [6] Transient-Based Fault-Location Method for Multiterminal Lines Employing S-Transform
    Ahmadimanesh, Alireza
    Shahrtash, S. Mohammad
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1373 - 1380
  • [7] A New Transient-Based Earth Fault Protection System for Unearthed Meshed Distribution Networks
    Rios Penaloza, Juan Diego
    Borghetti, Alberto
    Napolitano, Fabio
    Tossani, Fabio
    Nucci, Carlo Alberto
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (05) : 2585 - 2594
  • [8] High-frequency transient comparison based fault location in distribution systems with DGs
    Jia, Ke
    Ren, Zhefeng
    Li, Lun
    Xuan, Zhenwen
    Thomas, David
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (16) : 4068 - 4077
  • [9] Transient-Based Fault Location on Three-Terminal and Tapped Transmission Lines Not Requiring Line Parameters
    Davoudi, Masoud
    Sadeh, Javad
    Kamyab, Ebadollah
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) : 179 - 188
  • [10] A new single end wideband impedance based fault location scheme for distribution systems
    Aboshady, F. M.
    Thomas, D. W. P.
    Sumner, Mark
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 173 : 263 - 270