Full-range Fourier domain optical coherence tomography imaging probe with a magnetic-driven resonant fiber cantilever

被引:11
|
作者
Zhang, Kang [1 ]
Huang, Yong [2 ]
Kang, Jin U. [2 ]
机构
[1] Gen Elect Global Res Ctr, Niskayuna, NY 12309 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
关键词
full-range optical coherence tomography; forward-viewing imaging probe; phase modulation; GRAPHICS PROCESSING UNIT; MEMS SCANNING CATHETER; HIGH-SPEED; ULTRAHIGH-RESOLUTION; SWEPT LASER; OCT; ENDOSCOPE; MICROSURGERY; ACTUATOR; SCANS;
D O I
10.1117/1.3645088
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, we developed a full-range Fourier domain optical coherence tomography (FD-OCT) imaging probe with a magnetic-driven resonant fiber cantilever. A galvanometer-driven reference mirror provides a linear phase modulation to each M-scan/B-scan frame to enable complex conjugate-free, full-range FD-OCT imaging. A fiber cantilever inside the probe is driven by a low-voltage miniature magnetic transducer. The fiber cantilever scans at its resonant frequency synchronized to the phase modulation induced by the reference mirror. Using a CCD line-scan camera-based spectrometer, we demonstrated real-time full-range FD-OCT at 34 frame/s (1024 pixel lateral x 2048 pixel axial). (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3645088]
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Real time and full-range complex fourier domain optical coherence tomography
    Yasuno, Y
    Makita, S
    Endo, T
    Aoki, G
    Itoh, M
    Yatagai, T
    OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (13-15) : 1157 - 1163
  • [2] Real time and full-range complex Fourier domain optical coherence tomography
    Yasuno, Y
    Makita, S
    Endo, T
    Aoki, G
    Itoh, M
    Yatagai, T
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 32 - 33
  • [3] Real Time and Full-range Complex Fourier Domain Optical Coherence Tomography
    Yoshiaki Yasuno
    Shuichi Makita
    Takashi Endo
    Gouki Aoki
    Masahide Itoh
    Toyohiko Yatagai
    Optical and Quantum Electronics, 2005, 37 : 1157 - 1163
  • [4] Full-range spectral domain Doppler optical coherence tomography
    Meemon, P.
    Lee, K. S.
    Rolland, J. P.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES III, 2010, 7556
  • [5] Full-range Fourier domain Doppler optical coherence tomography based on sinusoidal phase modulation
    Nan, Nan
    Wang, Xiangzhao
    Bu, Peng
    Li, Zhongliang
    Guo, Xin
    Chen, Yan
    Wang, Xuan
    Yuan, Fenghua
    Sasaki, Osami
    APPLIED OPTICS, 2014, 53 (12) : 2669 - 2676
  • [7] Miniaturized magnetic-driven scanning probe for endoscopic optical coherence tomography
    Pang, Ziwei
    Wu, Jigang
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (06): : 2231 - 2236
  • [8] Imaging the ocular anterior segment with real-time, full-range Fourier-Domain optical coherence tomography
    Sarunic, Marinko V.
    Asrani, Sanjay
    Izatt, Joseph A.
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (04) : 537 - 542
  • [9] High-sensitive full-range optical vibrometry based on Fourier-domain optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [10] Full-range optical coherence refraction tomography
    Huang, Yong
    Qiao, Zhengyu
    Chen, Jingsi
    Zhang, Dan
    Hao, Qun
    OPTICS LETTERS, 2022, 47 (04) : 894 - 897