Heat transfer characteristics of the fluidized bed through the annulus

被引:4
|
作者
Shedid, Mohamed H. [1 ]
Hassan, M. A. M. [1 ]
机构
[1] Helwan Univ, Dept Mech Engn, Fac Engn El Mattaria, Cairo, Egypt
关键词
TRANSFER COEFFICIENTS; HORIZONTAL TUBE; WALL; PREDICTION; DEPENDENCE; CONVECTION; SURFACES;
D O I
10.1007/s00231-015-1722-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
The annular fluidized bed can be regarded as a promising technique for waste heat recovery applications. This study investigates on the determination of steady state values of the average heat transfer on the surface of the inner tube under different operating conditions that include: (1) input heat flux ranging from 557 to 1671 W/m(2), (2) superficial air velocity ranging between 0.12 and 0.36 m/s, (3) initial bed height ranging from 25 to 55 cm, (4) ratio of the inner to the outer diameters ranging from 1/6 to 1/2 and Kaolin particle diameters ranging between 282 and 550 A mu m. The average values of the heat transfer coefficient along the inner tube (consisting of the fluidized and free board sections) are also deduced. An empirical correlation for calculating the Nusselt number is obtained for the given parameters and ranges.
引用
收藏
页码:1943 / 1952
页数:10
相关论文
共 50 条
  • [1] Heat transfer characteristics of the fluidized bed through the annulus
    Mohamed H. Shedid
    M. A. M. Hassan
    Heat and Mass Transfer, 2016, 52 : 1943 - 1952
  • [2] Heat transfer characteristics in a horizontal swirling fluidized bed
    Lu, Ping
    Cao, Yan
    Pan, Wei-Ping
    Ma, Chengguo
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (06) : 1127 - 1134
  • [3] Heat transfer characteristics in fluidized bed with liquid spray
    Zhejiang Univ, Hangzhou, China
    Huagong Xuebao, 4 (489-494):
  • [4] Bed-to-wall heat transfer characteristics in a circulating fluidized bed
    Cho, YJ
    Kim, SD
    Han, GY
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 1996, 13 (06) : 627 - 632
  • [5] Heat transfer characteristics in a pulsated fluidized bed in relation to bubble characteristics
    Nishimura, A
    Deguchi, S
    Matsuda, H
    Hasatani, M
    Mujumdar, AS
    KAGAKU KOGAKU RONBUNSHU, 2000, 26 (06) : 830 - 836
  • [6] Heat transfer characteristics in a pulsating fluidized bed in relation to bubble characteristics
    Nishimura, Akira
    Deguchi, Seiichi
    Matsuda, Hitoki
    Hasatani, Masanobu
    Mujumdar, Arun S.
    Heat Transfer - Asian Research, 2002, 31 (04): : 307 - 319
  • [7] FLUIDIZED BED HEAT TRANSFER
    WAMSLEY, WW
    JOHANSON, LN
    CHEMICAL ENGINEERING PROGRESS, 1954, 50 (07) : 347 - 355
  • [8] Drying and heat transfer characteristics for a novel fluidized bed dryer
    Reyes, A
    Eckholt, M
    Alvarez, PI
    DRYING TECHNOLOGY, 2004, 22 (08) : 1869 - 1895
  • [9] HEAT-TRANSFER CHARACTERISTICS IN A ROCKING FLUIDIZED-BED
    YASUI, T
    NAKAYAMA, T
    YOSHIDA, K
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1984, 11 (05) : 477 - 488
  • [10] Experiments on the local heat transfer characteristics of a circulating fluidized bed
    Pagliuso, JD
    Lombardi, G
    Goldstein, L
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2000, 20 (3-4) : 170 - 179