Quantitative coronary angiography versus intravascular ultrasound guidance for drug-eluting stent implantation (GUIDE-DES): study protocol for a randomised controlled non-inferiority trial

被引:10
|
作者
Lee, Pil Hyung [1 ]
Hong, Soon Jun [2 ]
Kim, Hyun-Sook [3 ]
Yoon, Young Won [4 ]
Lee, Jong-Young [5 ]
Oh, Seung-Jin [6 ]
Kang, Soo-Jin [1 ]
Kim, Young-Hak [1 ]
Park, Seong-Wook [1 ]
Lee, Seung-Whan [1 ]
Lee, Cheol Whan [1 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Internal Med, Div Cardiol,Coll Med, Seoul, South Korea
[2] Korea Univ, Cardiovasc Ctr, Dept Cardiol, Anam Hosp, Seoul, South Korea
[3] Hallym Univ, Dept Cardiol, Sacred Heart Hosp, Anyang, South Korea
[4] Yonsei Univ, Gangnam Severance Hosp, Div Cardiol, Coll Med, Seoul, South Korea
[5] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Internal Med, Div Cardiol,Sch Med, Seoul, South Korea
[6] Natl Hlth Insurance Serv Ilsan Hosp, Dept Cardiol, Gyeonggi Do, South Korea
来源
BMJ OPEN | 2022年 / 12卷 / 01期
关键词
CARDIOVASCULAR ANGIOGRAPHY; MYOCARDIAL-INFARCTION; IVUS; OUTCOMES; INTERVENTION; METAANALYSIS; PREDICTORS; LESIONS; REVASCULARIZATION; DEFINITION;
D O I
10.1136/bmjopen-2021-052215
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Angiography remains the gold standard for guiding percutaneous coronary intervention (PCI). However, it is prone to suboptimal stent results due to the visual estimation of coronary measurements. Although the benefit of intravascular ultrasound (IVUS)-guided PCI is becoming increasingly recognised, IVUS is not affordable for many catheterisation laboratories. Thus, a more practical and standardised angiography-based approach is necessary to support stent implantation. Methods and analysis The Quantitative Coronary Angiography versus Intravascular Ultrasound Guidance for Drug-Eluting Stent Implantation trial is a randomised, investigator-initiated, multicentre, open-label, non-inferiority trial comparing the quantitative coronary angiography (QCA)-guided PCI strategy with IVUS-guided PCI in all-comer patients with significant coronary artery disease. A novel, standardised, QCA-based PCI protocol for the QCA-guided group will be provided to all participating operators, while the PCI optimisation criteria will be predefined for both strategies. A total of 1528 patients will be randomised to either group at a 1:1 ratio. The primary endpoint is the 12-month cumulative incidence of target-lesion failure defined as a composite of cardiac death, target-vessel myocardial infarction or ischaemia-driven target-lesion revascularisation. Clinical follow-up assessments are scheduled at 1, 6 and 12 months for all patients enrolled in the study. Ethics and dissemination Ethics approval for this study was granted by the Institutional Review Board of Asan Medical Center (no. 2017-0060). Informed consent will be obtained from every participant. The study findings will be published in peer-reviewed journal articles and disseminated through public forums and academic conference presentations. Cost-effectiveness and secondary imaging analyses will be shared in secondary papers.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quantitative Coronary Angiography vs Intravascular Ultrasonography to Guide Drug-Eluting Stent Implantation A Randomized Clinical Trial
    Lee, Pil Hyung
    Hong, Soon Jun
    Kim, Hyun-Sook
    Yoon, Young won
    Lee, Jong-Young
    Oh, Seung-Jin
    Lee, Ji Sung
    Kang, Soo-Jin
    Kim, Young-Hak
    Park, Seong-Wook
    Lee, Seung-Whan
    Lee, Cheol Whan
    JAMA CARDIOLOGY, 2024, 9 (05) : 428 - 435
  • [2] Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation The ULTIMATE Trial
    Zhang, Junjie
    Gao, Xiaofei
    Kan, Jing
    Ge, Zhen
    Han, Leng
    Lu, Shu
    Tian, Nailiang
    Lin, Song
    Lu, Qinghua
    Wu, Xueming
    Li, Qihua
    Liu, Zhizhong
    Chen, Yan
    Qian, Xuesong
    Wang, Juan
    Chai, Dayang
    Chen, Chonghao
    Li, Xiaolong
    Gogas, Bill D.
    Pan, Tao
    Shan, Shoujie
    Ye, Fei
    Chen, Shao-Liang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (24) : 3126 - 3137
  • [3] Quantitative Coronary Angiography Guidance for Drug-Eluting Stent Implantation: A Narrative Review
    Lee, Cheol Whan
    Lee, Pil Hyung
    Lee, Seung-Whan
    Serruys, Patrick W.
    HEALTH SCIENCE REPORTS, 2024, 7 (12)
  • [4] Efficacy and Safety of Indobufen versus Aspirin After Coronary Drug-Eluting Stent Implantation: A Randomized, Open-Label, Non-Inferiority Trial
    Wu, Hongyi
    Xu, Lili
    Zhao, Xin
    Zhang, Huanyi
    Cheng, Kang
    Wang, Xiaoyan
    Chen, Manhua
    Li, Guangping
    Huang, Jiangnan
    Zhang, Chi
    Wang, Yinman
    Ge, Lei
    Qian, Juying
    Ge, Junbo
    CIRCULATION, 2022, 146 (25) : E578 - E578
  • [5] Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation A Health Economic Analysis
    Zhou, Jennifer
    Liew, Danny
    Duffy, Stephen J.
    Shaw, James
    Walton, Antony
    Chan, William
    Gerber, Robert
    Stub, Dion
    CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2021, 14 (05): : E006789
  • [6] 3-Year Outcomes of the ULTIMATE Trial Comparing Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation
    Gao, Xiao-Fei
    Ge, Zhen
    Kong, Xiang-Quan
    Kan, Jing
    Han, Leng
    Lu, Shu
    Tian, Nai-Liang
    Lin, Song
    Lu, Qing-Hua
    Wang, Xiao-Yan
    Li, Qi-Hua
    Liu, Zhi-Zhong
    Chen, Yan
    Qian, Xue-Song
    Wang, Juan
    Chai, Da-Yang
    Chen, Chong-Hao
    Pan, Tao
    Ye, Fei
    Zhang, Jun-Jie
    Chen, Shao-Liang
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (03) : 247 - 257
  • [7] Sequential intravascular ultrasound after implantation of the sirolimus drug-eluting stent at coronary bifurcations: a three-dimensional intravascular ultrasound study
    Spanos, V
    Colombo, A
    Leon, M
    Moses, J
    Morice, MC
    Di Mario, C
    Ludvig, J
    Holmes, D
    EUROPEAN HEART JOURNAL, 2003, 24 : 637 - 637
  • [8] Does intravascular ultrasound guidance during percutaneous coronary intervention prevent stent thrombosis after implantation of drug-eluting stents?
    Roy, Probal
    Buch, Ashesh N.
    Javaid, Aamir
    Okabe, Teruo
    Slottow, Tina L. Pinto
    Steinberg, Daniel H.
    Smith, Kimberly
    Xue, Zhenyi
    Satler, Lowell F.
    Kent, Kenneth M.
    Suddath, William O.
    Pichard, Augusto D.
    Waksman, Ron
    CIRCULATION, 2007, 116 (16) : 360 - 361
  • [9] Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial
    Ali, Ziad A.
    Maehara, Akiko
    Genereux, Philippe
    Shlofmitz, Richard A.
    Fabbiocchi, Franco
    Nazif, Tamim M.
    Guagliumi, Giulio
    Meraj, Perwaiz M.
    Alfonso, Fernando
    Samady, Habib
    Akasaka, Takashi
    Carlson, Eric B.
    Leesar, Massoud A.
    Matsumura, Mitsuaki
    Ozan, Melek Ozgu
    Mintz, Gary S.
    Ben-Yehuda, Ori
    Stone, Gregg W.
    LANCET, 2016, 388 (10060): : 2618 - 2628
  • [10] Fully automated quantitative coronary angiography versus optical coherence tomography guidance for coronary stent implantation (FLASH): Study protocol for a randomized controlled noninferiority trial
    Kim, Yongcheol
    Park, Hanbit
    Yoon, Hyuck-Jun
    Suh, Jon
    Kang, Si-Hyuck
    Lim, Young-Hyo
    Jang, Duck Hyun
    Park, Jae Hyoung
    Shin, Eun-Seok
    Bae, Jang-Whan
    Lee, Jang Hoon
    Oh, Jun-Hyok
    Kang, Do-Yoon
    Kweon, Jihoon
    Jo, Min-Woo
    Park, Duk-Woo
    Kim, Young-Hak
    Ahn, Jung-Min
    AMERICAN HEART JOURNAL, 2024, 275 : 86 - 95