Direct comparison of ten quantitative fecal immunochemical tests for hemoglobin stability in colorectal cancer screening

被引:19
|
作者
Gies, Anton [1 ,2 ,3 ]
Cuk, Katarina [4 ]
Schrotz-King, Petra [1 ,2 ]
Brenner, Hermann [1 ,2 ,4 ,5 ]
机构
[1] German Canc Res Ctr, Div Prevent Oncol, Heidelberg, Germany
[2] Natl Ctr Tumor Dis NCT, Heidelberg, Germany
[3] Heidelberg Univ, Med Fac Heidelberg, Heidelberg, Germany
[4] German Canc Res Ctr, Div Clin Epidemiol & Aging Res, Heidelberg, Germany
[5] German Canc Res Ctr, German Canc Consortium DKTK, Heidelberg, Germany
关键词
OCCULT BLOOD-TESTS; DIAGNOSTIC PERFORMANCE; AMBIENT-TEMPERATURE; SAMPLE RETURN; METAANALYSIS; POPULATION; TRIAL; RATES;
D O I
10.1038/s41424-018-0035-2
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives: To systematically investigate and directly compare, for the first time, the sample stability of a large number of quantitative fecal immunochemical tests (FITs) at different storage conditions. Methods: Stool samples were obtained from participants of the German screening colonoscopy program between 2005 and 2010. After an initial FIT-based hemoglobin (Hb) measurement, stool samples were kept frozen at -80 degrees C until analysis. Twenty randomly selected participants with initial measurements ranging from 10 to 100 mu g Hb/g feces were included. Ten quantitative FITs were investigated in parallel. A defined stool amount was extracted using each manufacturer's brand-specific fecal sampling device and stored at 5 degrees C, 20 degrees C, and 35 degrees C, respectively. After 1, 4, 5, and 7 days, the samples were analyzed blinded. Median fecal Hb concentrations and positivity rates were calculated. Results: Mean age of the participants was 67 years (range: 56-80 years) and 60% were male. The most advanced finding at screening colposcopy was advanced adenoma in five and non-advanced adenoma in eight cases. Hyperplastic polyps were found in two participants and five participants were without any findings. At 5 degrees C storage temperature, almost all FITs showed fairly stable results throughout the 7-day observation period. At 20 degrees C, most FITs still showed fairly stable results over 4 days, whereas positivity rates significantly declined from day 4 on for most FITs at 35 degrees C. Major differences regarding the sample stability between FITs were observed. Conclusion: FIT-specific Hb decay according to ambient temperature and time period between sampling and test evaluation requires careful consideration in the design of FIT-based screening programs.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Direct Comparison of Diagnostic Performance of 9 Quantitative Fecal Immunochemical Tests for Colorectal Cancer Screening
    Gies, Anton
    Cuk, Katarina
    Schrotz-King, Petra
    Brenner, Hermann
    GASTROENTEROLOGY, 2018, 154 (01) : 93 - 104
  • [2] Quantitative fecal immunochemical tests for colorectal cancer screening
    Gies, Anton
    Bhardwaj, Megha
    Stock, Christian
    Schrotz-King, Petra
    Brenner, Hermann
    INTERNATIONAL JOURNAL OF CANCER, 2018, 143 (02) : 234 - 244
  • [3] Fecal Immunochemical Tests for Colorectal Cancer Screening
    Daly, Jeanette
    AMERICAN JOURNAL OF NURSING, 2012, 112 (10) : 67 - 69
  • [4] A comparison of qualitative and quantitative fecal immunochemical tests in the Korean national colorectal cancer screening program
    Park, Mi Jin
    Choi, Kui Son
    Lee, You Kyoung
    Jun, Jae Kwan
    Lee, Hoo-Yeon
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2012, 47 (04) : 461 - 466
  • [5] Analytical Comparison of Three Quantitative Immunochemical Fecal Occult Blood Tests for Colorectal Cancer Screening
    Guittet, Lydia
    Guillaume, Elodie
    Levillain, Romuald
    Beley, Philippe
    Tichet, Jean
    Lantieri, Olivier
    Launoy, Guy
    CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2011, 20 (07) : 1492 - 1501
  • [6] Screening for colorectal cancer: Direct comparison of a brush-sampling fecal immunochemical test for hemoglobin with Hemoccult
    Cole, S
    Smith, A
    Bampton, P
    Sandford, J
    Morcom, J
    Young, GP
    GASTROINTESTINAL ENDOSCOPY, 2003, 57 (05) : AB95 - AB95
  • [7] Screening for colorectal cancer: Direct comparison of a brush-sampling fecal immunochemical test for hemoglobin with hemoccult
    Cole, M
    Smith, A
    Bampton, P
    Sandford, J
    Morcom, J
    Young, GP
    GASTROENTEROLOGY, 2003, 124 (04) : A80 - A80
  • [8] Predictive power of quantitative and qualitative fecal immunochemical tests for hemoglobin in population screening for colorectal neoplasm
    Huang, Yanqin
    Li, Qilong
    Ge, Weiting
    Cai, Shanrong
    Zhang, Suzhan
    Zheng, Shu
    EUROPEAN JOURNAL OF CANCER PREVENTION, 2014, 23 (01) : 27 - 34
  • [9] Evaluation of Fecal Immunochemical Tests for Colorectal Cancer Screening
    Daly, Jeanette M.
    Bay, Camden P.
    Levy, Barcey T.
    JOURNAL OF PRIMARY CARE AND COMMUNITY HEALTH, 2013, 4 (04): : 245 - 250
  • [10] Fecal immunochemical test for hemoglobin in combination with fecal transferrin in colorectal cancer screening
    Gies, Anton
    Cuk, Katarina
    Schrotz-King, Petra
    Brenner, Hermann
    UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2018, 6 (08) : 1223 - 1231