Value of Baseline Post-Transplant MAG3 Renal Scintigraphy in the Evaluation of Graft Function
被引:1
|
作者:
Boey, Ching Yeen
论文数: 0引用数: 0
h-index: 0
机构:
Hosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
Univ Sains Malaysia, Adv Med & Dent Inst, Nucl Med Dept, Gelugor, Penang, Malaysia
Hosp Kuala Lumpur, Nephrol Dept, Kuala Lumpur, MalaysiaHosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
Boey, Ching Yeen
[1
,2
,3
]
Yee, Seow Yeing
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sains Malaysia, Adv Med & Dent Inst, Nucl Med Dept, Gelugor, Penang, Malaysia
Hosp Kuala Lumpur, Nephrol Dept, Kuala Lumpur, MalaysiaHosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
Yee, Seow Yeing
[2
,3
]
Hassan, Siti Zarina Amir
论文数: 0引用数: 0
h-index: 0
机构:
Hosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, MalaysiaHosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
Hassan, Siti Zarina Amir
[1
]
Yahya, Rosnawati
论文数: 0引用数: 0
h-index: 0
机构:
Hosp Kuala Lumpur, Nephrol Dept, Kuala Lumpur, MalaysiaHosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
Yahya, Rosnawati
[3
]
Hashim, Hazlin
论文数: 0引用数: 0
h-index: 0
机构:Hosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
Hashim, Hazlin
机构:
[1] Hosp Kuala Lumpur, Nucl Med Dept, Kuala Lumpur, Malaysia
[2] Univ Sains Malaysia, Adv Med & Dent Inst, Nucl Med Dept, Gelugor, Penang, Malaysia
[3] Hosp Kuala Lumpur, Nephrol Dept, Kuala Lumpur, Malaysia
Introduction. Accurate assessment of renal graft function in the early post-transplant period is crucial, as it influences clinical management and graft prognostication. However, there are limitations in current available modalities. MAG3 scintigraphy could contribute vital information on graft function. Objectives. This study aimed to determine the predictive value of parameters derived from MAG3 performed within 72 hours post transplant in detecting graft function. Delayed graft function (DGF), which is defined as dialysis requirement within the first week post transplant, is chosen as a surrogate measure of graft function. Methodology. All renal transplant recipients who underwent MAG3 within 72 hours post transplant from 2017 to 2019 were enrolled. Three MAG3 parameters, renogram grade, tubular injury severity score, and R20:3, were evaluated. Results. A total of 117 patients were enrolled. The overall incidence of DGF was 16.2% with a significantly higher incidence amongst cadaveric graft recipients (53.6%) compared with living graft recipients (4.5%). Renogram grade >2, tubular injury severity score >4, and R20:3 > 1.31 significantly predicted DGF, P < .05 with high area under the curve for R20:3 of 0.97. Grafts with parameters above the cutoffs also showed significantly worse GFR at 1- and 3-months posttransplant. On multivariate analysis, prolonged cold ischemia time was associated with a higher risk of DGF, odds ratio 1.005 (95% confidence interval 1.003-1.007), P < .05. Conclusion. Baseline MAG3 accurately depicts early graft function and was also predictive of GFR at 1- and 3- months post-transplant. These baseline MAG3 scans could be particularly useful amongst deceased donor graft recipients owing to the higher risk of poor graft function.
机构:
Boston Childrens Hosp, Div Nephrol, Boston, MA USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Div Nephrol, Boston, MA USA
Hunt, Elizabeth A. K.
Ashoor, Isa F.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Div Nephrol, Boston, MA USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Div Nephrol, Boston, MA USA
Ashoor, Isa F.
deJesus-Gonzalez, Nilka
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Div Nephrol, Boston, MA USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Div Nephrol, Boston, MA USA
deJesus-Gonzalez, Nilka
Somers, Michael J. G.
论文数: 0引用数: 0
h-index: 0
机构:
Boston Childrens Hosp, Div Nephrol, Boston, MA USA
Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USABoston Childrens Hosp, Div Nephrol, Boston, MA USA