Experimental imaging of intracorneal ring segments with optical coherence tomography

被引:0
|
作者
Wirbelauer, C
Winkler, J
Scholz, C
Häberle, H
Pham, DT
机构
[1] Vivantes Klinikum Neukolln, Klin Augenheilkunde, D-12351 Berlin, Germany
[2] Med Univ Lubeck, Augenklin, D-23538 Lubeck, Germany
[3] 4Optics AG, Lubeck, Germany
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the imaging of corneal structures with optical coherence tomography (OCT) after implantation of intracorneal ring segments (ICRS). METHODS: In an experimental study with six porcine eyes, qualitative and quantitative imaging with corneal OCT using a wavelength of 1310 nm after implantation of ICRS was performed. The optical results were compared with light microscopy of the histological sections. RESULTS: In corneal OCT, the ICRS revealed marked hyporeflective intrastromal areas, which correlated well with macroscopic and microscopic findings. Corneal OCT enabled precise images of the incision depth for the implantation of ICRS, and the exact intrastromal segment position. CONCLUSIONS: Noncontact slit lamp-adapted corneal optical coherence tomography could be employed to clinically monitor corneal changes after implantation of ICRS, evaluate the depth of the segments to correlate refractive changes, and quantify the stromal wound healing response.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 50 条
  • [1] Ocular and Optical Coherence Tomography-Based Corneal Aberrometry in Keratoconic Eyes Treated by Intracorneal Ring Segments
    Perez-Merino, Pablo
    Ortiz, Sergio
    Alejandre, Nicolas
    De Castro, Alberto
    Jimenez-Alfaro, Ignacio
    Marcos, Susana
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (01) : 116 - 127
  • [2] Intracorneal ring segments for keratoconus
    Ertan, Aylin
    Muftuoglu, Orkun
    EXPERT REVIEW OF OPHTHALMOLOGY, 2008, 3 (05) : 585 - 597
  • [3] Intracorneal ring segments in keratoconus
    El-Husseiny, M.
    Tsintarakis, T.
    Eppig, T.
    Langenbucher, A.
    Seitz, B.
    OPHTHALMOLOGE, 2013, 110 (09): : 823 - +
  • [4] Reliability of corneal tomography after implantation of intracorneal ring segments for keratoconus
    Matar, C.
    Daas, L.
    Suffo, S.
    Langenbucher, A.
    Seitz, B.
    Eppig, T.
    OPHTHALMOLOGE, 2020, 117 (11): : 1092 - 1099
  • [5] Comparison of corneal epithelial thickness before and after corneal cross-linking surgery with and without intracorneal ring segments using optical coherence tomography
    Haines, Lacey
    Kralj, Olivera
    Marschall, Sebastian
    Gawish, Ahmed
    Fieguth, Paul
    Singal, Neera
    Chew, Hall
    Rootman, David
    Slomovic, Allan
    Hatch, Wendy
    Bizheva, Kostadinka K.
    Sorbara, Luigina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [6] Ferrara intracorneal ring segments for keratoconus
    Kwitko, S
    Severo, NS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04): : 812 - 820
  • [7] Effectiveness of intracorneal ring segments for keratoconus
    Park, Se Eun
    Tseng, Michael
    Lee, Jimmy K.
    CURRENT OPINION IN OPHTHALMOLOGY, 2019, 30 (04) : 220 - 228
  • [8] The use of intracorneal ring segments in keratoconus
    Alfredo Vega-Estrada
    Jorge L. Alio
    Eye and Vision, 3
  • [9] Optical coherence tomography: an experimental validation for vascular imaging
    Wilson, Rebekah
    Ju, Xiangyang
    Paterson, Craig
    Going, James
    Berry, Colin
    SCOTTISH MEDICAL JOURNAL, 2014, 59 (01) : E36 - E36
  • [10] Intracorneal ring segments in keratoconus management
    David, C.
    Kallel, S.
    Trinh, L.
    Goemaere, I
    Borderie, V
    Bouheraoua, N.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (06): : 882 - 898