Antimony nanomaterials modified screen-printed electrodes for the voltammetric determination of metal ions

被引:8
|
作者
Tapia, Maria A. [1 ]
Perez-Rafols, Clara [1 ,2 ]
Pastika, Jan [3 ]
Gusmao, Rui [3 ]
Serrano, Nuria [1 ,2 ,4 ]
Sofer, Zdenek [3 ]
Diaz-Cruz, Jose Manuel [1 ,2 ]
机构
[1] Univ Barcelona UB, Dept Chem Engn & Analyt Chem, Marti & Franques 1-11, Barcelona 08028, Spain
[2] Univ Barcelona, Water Res Inst IdRA, Marti & Franques 1-11, Barcelona 08028, Spain
[3] Univ Chem & Technol Prague, Dept Inorgan Chem, Technicka 5, Prague 6, Czech Republic
[4] Univ Barcelona, Dept Chem Engn & Analyt Chem, Marti & Franques 1-11, Barcelona 08028, Spain
关键词
Antimonene; Antimony chalcogenide; Layered materials; Screen-printed electrodes; Stripping voltammetry; CARBON-PASTE ELECTRODES; ELECTROCHEMICAL STRIPPING DETERMINATION; FILM ELECTRODE; HEAVY-METALS; PB(II);
D O I
10.1016/j.electacta.2022.140690
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Exfoliated beta-Sb or two dimensional (2D) antimonene-based modified screen-printed electrode (2D Sb SPCE), prepared by drop-casting of an exfoliated layered beta-antimony (2D Sb) suspension, was used for the simultaneous determination of Pb(II) and Cd(II) by differential pulse anodic stripping voltammetry (DPASV). 2D Sb SPCE was characterized by microscopic and analytical techniques, and compared not only to bare SPCE but also to layered antimony chalcogenides based-sensors. Both Sb2Te3 and Sb2Te3 have an isomorphous tubular one-dimensional (1D) crystal structure, whereas Sb2Te3 and monoelement beta-Sb have a 2D layered structure. Under optimized conditions, 2D Sb-SPCE displays an excellent analytical performance with detection limits of 0.3 and 2.7 mu g L-1 for Pb(II) and Cd(II), respectively, and a linear response from 1.1 to 128.3 mu g L-1 for Pb(II) and from 9.1 to 132.7 mu g L-1 for Cd(II). Moreover, 2D Sb-SPCE was successfully applied for the DPASV determination of Pb(II) and Cd (II) in tap water, achieving statistically comparable results to those provided by ICP-MS measurements.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Selenocystine modified screen-printed electrode as an alternative sensor for the voltammetric determination of metal ions
    Puy-Llovera, Jaume
    Perez-Rafols, Clara
    Serrano, Nutiria
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    Esteban, Miguel
    TALANTA, 2017, 175 : 501 - 506
  • [2] Screen-printed electrodes modified with functionalized mesoporous silica for voltammetric analysis of toxic metal ions
    Yantasee, W
    Deibler, LA
    Fryxell, GE
    Timchalk, C
    Lin, YH
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (11) : 1170 - 1176
  • [3] Enhanced voltammetric determination of metal ions by using a bismuthene-modified screen-printed electrode
    Tapia, Maria A.
    Perez-Rafols, Clara
    Gusmao, Rui
    Serrano, Nuria
    Sofer, Zdenek
    Manuel Diaz-Cruz, Jose
    ELECTROCHIMICA ACTA, 2020, 362
  • [4] Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Arino, Cristina
    Esteban, Miquel
    TALANTA, 2016, 155 : 8 - 13
  • [5] Voltammetric determination of Rutin at Screen-Printed carbon disposable electrodes
    de Oliveira-Roberth, Aline
    Santos, Diego I. V.
    Cordeiro, Diogo D.
    Lino, Fernando M. de A.
    Bara, Maria T. F.
    Gil, Eric de S.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (05): : 1609 - 1616
  • [6] Stripping Voltammetric Measurement of Trace Metal Ions at Screen-printed Carbon and Carbon Paste Electrodes
    Somerset, Vernon
    Iwuoha, Emmanuel
    Hernandez, Lucas
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1279 - +
  • [7] Dimethylglyoxime modified screen-printed electrodes for nickel determination
    Rosal, Miguel
    Ceto, Xavier
    Serrano, Nuria
    Arino, Cristina
    Esteban, Miquel
    Manuel Diaz-Cruz, Jose
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 839 : 83 - 89
  • [8] Voltammetric Determination of Active Pharmaceutical Ingredients Using Screen-Printed Electrodes
    Clares, Paula
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    CHEMOSENSORS, 2022, 10 (03)
  • [9] Voltammetric determination of sulfamethoxazole using commercial screen-printed carbon electrodes
    Alberto, Elena
    Bastos-Arrieta, Julio
    Perez-Rafols, Clara
    Serrano, Nuria
    Diaz-Cruz, M. Silvia
    Diaz-Cruz, Jose Manuel
    MICROCHEMICAL JOURNAL, 2023, 193
  • [10] Voltammetric Determination of Anticancer Drug Flutamide at Screen-Printed Carbon Electrodes
    Vyskocil, Vlastimil
    Navratil, Tomas
    Barek, Jiri
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 190 - 194