Determination of the Highly Sensitive Carboxyl-Graphene Oxide-Based Planar Optical Waveguide Localized Surface Plasmon Resonance Biosensor

被引:2
|
作者
Chen, Chien-Hsing [1 ]
Chiang, Chang-Yue [2 ,3 ]
机构
[1] Natl Pingtung Univ Sci & Technol, Dept Biomechatron Engn, Pingtung 91201, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Grad Sch Engn Sci & Technol, Touliu 64002, Yunlin, Taiwan
[3] Natl Yunlin Univ Sci & Technol, Bachelor Program Interdisciplinary Studies, Touliu 64002, Yunlin, Taiwan
关键词
graphene oxide; waveguide; gold nanoparticle; localized surface plasmon resonance; anti-IgG-IgG; biotin-streptavidin; affinity constant; GOLD NANOPARTICLE SENSOR; LOW-COST; FIBER;
D O I
10.3390/nano12132146
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study develops a highly sensitive and low-cost carboxyl-graphene-oxide-based planar optical waveguide localized surface plasmon resonance biosensor (GO-OW LSPR biosensor), a system based on measuring light intensity changes. The structure of the sensing chip comprises an optical waveguide (OW)-slide glass and microfluidic-poly (methyl methacrylate) (PMMA) substrate, and the OW-slide glass surface-modified gold nanoparticle (AuNP) combined with graphene oxide (GO). As the GO has an abundant carboxyl group (-COOH), the number of capture molecules can be increased. The refractive index sensing system uses silver-coated reflective film to compare the refractive index sensitivity of the GO-OW LSPR biosensor to increase the refractive index sensitivity. The result shows that the signal variation of the system with the silver-coated reflective film is 1.57 times that of the system without the silver-coated reflective film. The refractive index sensitivity is 5.48 RIU-1 and the sensor resolution is 2.52 +/- 0.23 x 10(-6) RIU. The biochemical sensing experiment performs immunoglobulin G (IgG) and streptavidin detection. The limits of detection of the sensor for IgG and streptavidin are calculated to be 23.41 +/- 1.54 pg/mL and 5.18 +/- 0.50 pg/mL, respectively. The coefficient of variation (CV) of the repeatability experiment (sample numbers = 3) is smaller than 10.6%. In addition, the affinity constants of the sensor for anti-IgG/IgG and biotin/streptavidin are estimated to be 1.06 x 10(7) M-1 and 7.30 x 10(9) M-1, respectively. The result shows that the GO-OW LSPR biosensor has good repeatability and very low detection sensitivity. It can be used for detecting low concentrations or small biomolecules in the future.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Highly sensitive carboxyl-graphene oxide-based surface plasmon resonance immunosensor for the detection of lung cancer for cytokeratin 19 biomarker in human plasma
    Chiu, Nan-Fu
    Lin, Ting-Li
    Kuo, Chia-Tzu
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 264 - 272
  • [2] Graphene/Graphene Oxide-Based Ultrasensitive Surface Plasmon Resonance Biosensor
    Meshginqalam, Bahar
    Ahmadi, Mohammad Taghi
    Ismail, Razali
    Sabatyan, Arash
    PLASMONICS, 2017, 12 (06) : 1991 - 1997
  • [3] Graphene/Graphene Oxide-Based Ultrasensitive Surface Plasmon Resonance Biosensor
    Bahar Meshginqalam
    Mohammad Taghi Ahmadi
    Razali Ismail
    Arash Sabatyan
    Plasmonics, 2017, 12 : 1991 - 1997
  • [4] A Novel Graphene Oxide-Based Surface Plasmon Resonance Biosensor for Immunoassay
    Zhang, Hua
    Sun, Ying
    Gao, Shang
    Zhang, Jia
    Zhang, Hanqi
    Song, Daqian
    SMALL, 2013, 9 (15) : 2537 - 2540
  • [5] Highly sensitive carboxyl-graphene oxide-based SPR immunosensor for the detection of CA19-9 biomarker
    Chiu, Nan-Fu
    Fan, Shi-Yuan
    OPTICAL SENSORS 2019, 2019, 11028
  • [6] Graphene Oxide-Based Surface Plasmon Optical Fiber Biosensor for Thiamine Detection
    Kumari, Anamika
    Choudhary, Kuldeep
    Vyas, Vibha
    Kumar, Santosh
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (03) : 809 - 815
  • [7] Surface plasmon resonance biosensor based on integrated optical waveguide
    Dostálek, J
    Ctyroky, J
    Homola, J
    Brynda, E
    Skalsky, M
    Nekvindová, P
    Spirková, J
    Skvor, J
    Schröfel, J
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 8 - 12
  • [8] Preparation of graphene oxide-based surface plasmon resonance biosensor with Au bipyramid nanoparticles as sensitivity enhancer
    Zhang, Jia
    Sun, Ying
    Wu, Qiong
    Gao, Yan
    Zhang, Hua
    Bai, Yu
    Song, Daqian
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 116 : 211 - 218
  • [9] Highly sensitive nano-porous lattice biosensor based on localized surface plasmon resonance and interference
    Yeom, Se-Hyuk
    Kim, Ok-Geun
    Kang, Byoung-Ho
    Kim, Kyu-Jin
    Yuan, Heng
    Kwon, Dae-Hyuk
    Kim, Hak-Rin
    Kang, Shin-Won
    OPTICS EXPRESS, 2011, 19 (23): : 22882 - 22891
  • [10] Optical fiber affinity biosensor based on localized surface plasmon resonance
    Mitsui, K
    Handa, Y
    Kajikawa, K
    APPLIED PHYSICS LETTERS, 2004, 85 (18) : 4231 - 4233