Results from the CDE phase activity on neutron dosimetry for the international fusion materials irradiation facility test cell

被引:0
|
作者
Esposito, B
Bertalot, L
Maruccia, G
Petrizzi, L
Bignan, G
Blandin, C
Chauffriat, S
Lebrun, A
Recroix, H
Trapp, JP
Kaschuck, Y
机构
[1] ENEA, Assoc Euratom Fus, I-00044 Frascati, Italy
[2] CEA Cadarache, DRN, DER, SSAE,LSMR, F-13108 St Paul Durance, France
[3] TRINITI, Dept Fus Reactor Phys, Troitsk, Russia
关键词
IFMIF; CDE phasse activity; irradiation facility test cell; sub-minature fission chambers; multifoil activation; neutron dosimetry;
D O I
10.1016/S0920-3796(00)00341-0
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The international fusion materials irradiation facility (IFMIF) project deals with the study of an accelerator-based, deuterium-lithium source, producing high energy neutrons at sufficient intensity and irradiation volume to test samples of candidate materials for fusion energy reactors. IFMIF would also provide calibration and validation of data from fission reactor and other accelerator based irradiation tests. This paper describes the activity on neutron/gamma dosimetry (necessary for the characterization of the specimens' irradiation) performed in the frame of the IFMIF conceptual design evaluation (CDE) neutronics tasks. During the previous phase (conceptual design activity (CDA)) the multifoil activation method was proposed for the measurement of the neutron fluence and spectrum and a set of suitable foils was defined. The cross section variances and covariances of this set of foils have now been used for tests on the sensitivity of the IFMIF neutron spectrum determination to cross section uncertainties. The analysis has been carried out using the LSL-M2 code, which optimizes the neutron spectrum by means of a least-squares technique taking into account the variance and covariance files. In the second part of the activity, the possibility of extending to IFMIF the use of existing on-line in-core neutron/gamma monitors (to be located at several positions inside the IFMIF test cell, for beam control, safety and diagnostic purposes) has been studied. A feasibility analysis of the modifications required to adapt sub-miniature fission chambers (recently developed by CEA-Cadarache) to the high flux test module of the test cell has been carried out. The verification of this application pertinence and a gross definition of the in-core detector characteristics are described. The option of using self-powered neutron detectors (SPNDs) is also discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 50 条
  • [1] Neutron irradiation characteristics in international fusion materials irradiation facility
    Oyama, Y
    Noda, K
    Kosako, K
    Yamano, N
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1996, 233 : 1577 - 1581
  • [2] International fusion materials irradiation facility (IFMIF): User requirements and test cell design
    Ehrlich, K
    Moslang, A
    [J]. ANNUAL MEETING ON NUCLEAR TECHNOLOGY '97, 1997, : 550 - 553
  • [3] FUSION MATERIALS IRRADIATION TEST FACILITY A FACILITY FOR FUSION MATERIALS QUALIFICATION
    TREGO, AL
    HAGAN, JW
    OPPERMAN, EK
    BURKE, RJ
    [J]. NUCLEAR TECHNOLOGY-FUSION, 1983, 4 (02): : 695 - 700
  • [4] THE FUSION MATERIALS IRRADIATION TEST FACILITY
    LISKA, DJ
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (07): : 807 - 807
  • [5] Preliminary results of the International Fusion Materials Irradiation Facility deuteron injector
    Gobin, R.
    Adroit, G.
    Bogard, D.
    Bourdelle, G.
    Chauvin, N.
    Delferriere, O.
    Gauthier, Y.
    Girardot, P.
    Guiho, P.
    Harrault, F.
    Jannin, J. L.
    Loiseau, D.
    Mattei, P.
    Roger, A.
    Sauce, Y.
    Senee, F.
    Vacher, T.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [6] NEUTRON STREAMING ANALYSIS FOR SHIELD DESIGN OF THE FUSION MATERIALS IRRADIATION TEST FACILITY
    CARTER, LL
    [J]. NUCLEAR TECHNOLOGY-FUSION, 1982, 2 (02): : 286 - 300
  • [7] IFMIF - An international fusion materials irradiation facility
    Ehrlich, K
    Moslang, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 139 (1-4): : 72 - 81
  • [8] IFMIF - an international fusion materials irradiation facility
    Forschungszentrum Karlsruhe, Karlsruhe, Germany
    [J]. Nucl Instrum Methods Phys Res Sect B, 1-4 (72-81):
  • [9] EXPERIMENTATION IN THE FUSION MATERIALS IRRADIATION TEST FACILITY
    OPPERMAN, EK
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1982, 108 (1-2) : 28 - 28
  • [10] THE FUSION MATERIALS IRRADIATION TEST (FMIT) FACILITY
    HAGAN, JW
    OPPERMAN, EK
    TREGO, AL
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1984, 123 (1-3) : 958 - 964