Development of a planar-type high sensitivity metallic contaminant detector

被引:1
|
作者
Okabe, Shunsuke [1 ]
Sasada, Ichiro [1 ]
机构
[1] Kyushu Univ, Kasuga, Fukuoka 8160811, Japan
来源
AIP ADVANCES | 2017年 / 7卷 / 05期
关键词
D O I
10.1063/1.4978590
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Metallic contaminant detectors based on the balanced coil system are widely used in the food industry. In the balanced coil system, an excitation coil and two identical pickup coils are used in a way that the magnetic coupling of pickup coils to the excitation coil is cancelled with each other when no metallic contaminants present. In a conventional system, the excitation coil and the pickup coil are planar and are parallel, therefore the magnetic coupling is strong even if there is no metallic contaminant. Such strong magnetic coupling makes balancing procedure tedious. In this paper, we introduce a new coil system in which pickup coils are set orthogonal to the excitation coil, making the magnetic coupling much small compared to conventional counterpart. Pickup coils are equipped with thin magnetic cores and placed inside the excitation coil being parallel to the excitation coil plane. The balancing method consists of two steps; the one is geometrical and the other is digital processing including down conversion. Experiments are carried out to show the detection capability of ferromagnetic contaminants and non-magnetic contaminants. (C) 2017 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Polarization sensitivity and efficiency for a planar-type segmented germanium detector as a Compton polarimeter
    Lee, JH
    Lee, CS
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (1-2): : 125 - 133
  • [2] Study on polarization sensitivity of a planar-type segmented germanium detector for linearly polarized gamma rays
    Lee, JH
    Lee, CS
    Gono, Y
    [J]. NUCLEAR PHYSICS A, 2003, 718 : 553C - 555C
  • [3] Development of a customized leading-edge discriminator for a planar-type segmented germanium detector
    Kim, NY
    Lee, JH
    Kim, JY
    Lee, CS
    Jang, ZH
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 104 - 107
  • [4] New Process Development for Planar-Type CIC Tunneling Diodes
    Choi, Kwangsik
    Yesilkoy, Filiz
    Chryssis, Athanasios
    Dagenais, Mario
    Peckerar, Martin
    [J]. IEEE ELECTRON DEVICE LETTERS, 2010, 31 (08) : 809 - 811
  • [5] Electrical Analysis of a Planar-type Digital X-ray Detector with Inert Gas
    Yun, Min-seok
    Nam, Sang-hee
    Park, Sung-Kwang
    Jung, Suk-hee
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 56 (04) : 1083 - 1087
  • [6] PLANAR-TYPE GUNN DIODE OF INP
    MURAYAMA, K
    NAKAMURA, Y
    SHIBAYAMA, A
    DOHI, A
    OHMI, T
    ITO, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 1974, 13 (04) : 662 - 666
  • [7] A NEW PLANAR-TYPE HIGH-FREQUENCY CURRENT DETECTOR UTILIZING THE SKIN EFFECT IN SOFT MAGNETIC-MATERIALS
    YAMAGUCHI, M
    MATSUKI, H
    ARAI, KI
    MURAKAMI, K
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (05) : 3824 - 3826
  • [8] HIGH-SPEED PULSE RESPONSE OF PLANAR-TYPE GUNN DIODES
    NAKAMURA, M
    KURONO, H
    HIRAO, M
    TOYABE, T
    KODERA, H
    [J]. PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1971, 59 (06): : 1039 - &
  • [9] Characteristics of gamma-ray energy and timing spectra for a planar-type segmented germanium detector
    Kwon, YK
    Lee, CS
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2003, 42 (05) : 600 - 605
  • [10] ANALYSIS OF THE OPERATING CHARACTERISTICS OF A PLANAR-TYPE CURRENT DETECTOR AT 10-100MHZ RANGE
    YAMAGUCHI, M
    HIRAI, N
    ARAI, KI
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (06) : 5253 - 5255