Single-lens 3D digital image correlation system based on a bilateral telecentric lens and a bi-prism: Systematic error analysis and correction

被引:31
|
作者
Wu, Lifu [1 ]
Zhu, Jianguo [2 ]
Xie, Huimin [1 ]
Zhou, Mengmeng [1 ]
机构
[1] Tsinghua Univ, Dept Engn Mech, AML, Beijing 100084, Peoples R China
[2] Jiangsu Univ, Fac Civil Engn & Mech, Zhenjiang 212013, Peoples R China
基金
中国国家自然科学基金;
关键词
3D digital image correlation; Single-lens; Bi-prism; Bilateral telecentric lens; Systematic error; STEREOVISION SYSTEM; CALIBRATION METHOD; FRINGE PROJECTION; CAMERA;
D O I
10.1016/j.optlaseng.2016.02.006
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, we proposed a single-lens 3D digital image correlation (3D DIC) method and established a measurement system on the basis of a bilateral telecentric lens (BM) and a bi-prism. This system can retrieve the 3D morphology of a target and measure its deformation using a single BTL with relatively high accuracy. Nevertheless, the system still suffers from systematic errors caused by manufacturing deficiency of the bi-prism and distortion of the BTL. In this study, in-depth evaluations of these errors and their effects on the measurement results are performed experimentally. The bi-prism deficiency and the BTL distortion are characterized by two in-plane rotation angles and several distortion coefficients, respectively. These values are obtained from a calibration process using a chessboard placed into the field of view of the system; this process is conducted after the measurement of tested specimen. A modified mathematical model is proposed, which takes these systematic errors into account and corrects them during 3D reconstruction. Experiments on retrieving the 3D positions of the chessboard grid corners and the morphology of a ceramic plate specimen are performed. The results of the experiments reveal that ignoring the bi-prism deficiency will induce attitude error to the retrieved morphology, and the BTL distortion can lead to its pseudo out-of-plane deformation. Correcting these problems can further improve the measurement accuracy of the bi-prism-based single-lens 3D DIC system. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 42 条
  • [1] Single-lens 3D digital image correlation system based on a bilateral telecentric lens and a bi-prism: validation and application
    Wu, Lifu
    Zhu, Jianguo
    Xie, Huimin
    [J]. APPLIED OPTICS, 2015, 54 (26) : 7842 - 7850
  • [2] Virtual Epipolar Line Construction of Single-Lens Bi-Prism Stereovision System
    Wei Loon Kee
    Kah Bin Lim
    [J]. JournalofElectronicScienceandTechnology., 2012, 10 (02) - 101
  • [3] Virtual Epipolar Line Construction of Single-Lens Bi-Prism Stereovision System
    Wei Loon Kee
    Kah Bin Lim
    [J]. Journal of Electronic Science and Technology, 2012, (02) : 97 - 101
  • [4] Parameter error analysis of single-lens prism-based stereovision system
    Kee, Wei Loon
    Bai, Yading
    Lim, Kah Bin
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (03) : 367 - 373
  • [5] Virtual camera calibration and stereo correspondence of single-lens bi-prism stereovision system using geometrical approach
    Lim, Kah Bin
    Kee, Wei Loon
    Wang, Daolei
    [J]. SIGNAL PROCESSING-IMAGE COMMUNICATION, 2013, 28 (09) : 1059 - 1071
  • [6] Micro-prism type single-lens 3D aircraft telescope system
    Deng, Qing-Long
    Chen, Chien-Yue
    Cheng, Shun-Wen
    Sun, Wen-Shing
    Lin, Bor-Shyh
    [J]. OPTICS COMMUNICATIONS, 2012, 285 (24) : 5001 - 5007
  • [7] An Accurate Method for Shape Retrieval and Displacement Measurement Using Bi-Prism-Based Single Lens 3D Digital Image Correlation
    Wu, L. F.
    Zhu, J. G.
    Xie, H. M.
    Zhang, Q.
    [J]. EXPERIMENTAL MECHANICS, 2016, 56 (09) : 1611 - 1624
  • [8] An Accurate Method for Shape Retrieval and Displacement Measurement Using Bi-Prism-Based Single Lens 3D Digital Image Correlation
    L. F. Wu
    J. G. Zhu
    H. M. Xie
    Q. Zhang
    [J]. Experimental Mechanics, 2016, 56 : 1611 - 1624
  • [9] Micro bi-prism bi-telecentric single lens Stereo-DIC system using one-step calibration method
    Li, Xin
    Zhao, Jiaqing
    He, Sixuan
    Zhang, Zhengming
    [J]. OPTICS AND LASER TECHNOLOGY, 2024, 171
  • [10] A prism based single-lens multi-ocular stereo image capture system
    Xiao, Yong
    Lim, Kah Bin
    Yu, Wei Maio
    [J]. 12TH INTERNATIONAL MULTI-MEDIA MODELLING CONFERENCE PROCEEDINGS, 2006, : 469 - 472