Determination of glyoxal and methylglyoxal in atmospheric fine particulate matter by vortex-assisted micro-solid phase extraction and liquid chromatography-diode array detection

被引:15
|
作者
Naing, Nyi Nyi [1 ]
Lee, Hian Kee [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Environm Res Inst, T Lab Bldg 02-01,5A Engn Dr 1, Singapore 117411, Singapore
[2] Natl Univ Singapore, Dept Chem, 3 Sci Dr 3, Singapore 117543, Singapore
[3] Natl Univ Singapore, Trop Marine Sci Inst, S2S Bldg,18 Kent Ridge Rd, Singapore 119227, Singapore
关键词
alpha-dicarbonyl compounds; Micro-solid phase extraction; Atmospheric fine particulate matter; Derivatization; CARBON NANOTUBES; ORGANIC AEROSOL; ALDEHYDES; SORBENT; HPLC; QUANTIFICATION; GRAPHENE; IMPACT;
D O I
10.1016/j.chroma.2018.08.060
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of alpha-dicarbonyl compounds, glyoxal (Gly) and methyl glyoxal (Mgly), in atmospheric fine particulate matter PM2.5 (particulate matter with an aerodynamic diameter of less than 2.5 mu m) which play vital roles in generating secondary organic aerosols in the ambient air, was carried out by vortex-assisted micro-solid phase extraction (VA-mu-SPE)-liquid chromatography-diode array detection (LC-DAD), with on-sorbent derivatization by 2,4-dinitrophenylhydrazine (DNPH). This is the first time such an approach of combining on-sorbent derivatization and extraction in one step together with LC analysis has been applied to PM2.5. Extraction parameters such as selection of sorbent, extraction time, desorption time and sample volume were optimized using water samples spiked with Gly and Mgly. Under the most favourable conditions, good intra- (1.39%-2.78%) and inter-day (2.29%-6.56%) precision and linearity (ranging between 0.5 and 100 ng mL(-1)) along with coefficients of determination 0.998 and 0.997, were determined. The limits of detection were determined to be 0.14 ng mL(-1) (derivatized Gly) and 0.15 ng mL(-1) (derivatized Mgly) whereas the limits of quantification were 0.47 ng mL(-1) and 0.50 ng mL(-1), respectively. The developed method was successfully employed to the determination of Gly and Mgly associated with PM2.5. The latter was collected on glass fiber filters which were immersed in methanol: water (1:1 v/v) for mu-SPE, which was conducted using a sorbent pre-coated with DNPH. The concentrations of the Gly and Mgly were determined to be 0.38 ng m(-3) and 0.41 ng m(-3) in the sampled ambient air, with relative recoveries of between 69-97%. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [11] Vortex-assisted emulsification microextraction combined with vortex-assisted micro-solid-phase extraction for the determination of polycyclic aromatic hydrocarbons from environmental water samples
    Guo, Liang
    Lee, Hian Kee
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [12] Determination of eumelanin and pheomelanin in melanomas using solid-phase extraction and high performance liquid chromatography-diode array detection (HPLC-DAD) analysis
    Rioux, Benjamin
    Rouanet, Jacques
    Akil, Hussein
    Besse, Sophie
    Debiton, Eric
    Bouchon, Bernadette
    Degoul, Francoise
    Quintana, Mercedes
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1113 : 60 - 68
  • [13] Solid phase extraction of carbamate pesticides with porous organic polymer as adsorbent followed by high performance liquid chromatography-diode array detection
    Wang, Xiaolan
    Meng, Xufeng
    Wu, Qiuhua
    Wang, Chun
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1600 : 9 - 16
  • [14] Determination of Parabens in Cosmetics by Liquid-Phase Microextractions and High-Performance Liquid Chromatography-Diode Array Detection
    Jain, Archana
    Soni, Soumitra
    Verma, Krishna K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (01) : 82 - 91
  • [15] Exfoliated graphitic carbon nitride nanosheets for on-line vortex-assisted dispersive micro-solid phase extraction of indium prior to determination by ICP-OES
    Zolfonoun, Ehsan
    Yousefi, Seyed Reza
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (16) : 4031 - 4041
  • [16] Vortex-Assisted Liquid-Liquid Micro-extraction Followed by Head Space Solid Phase Micro-extraction for the Determination of Eugenol in Fish Using GC-MS
    Xu Liang
    Ting-Ting Feng
    Jian-Hai Wu
    Ming Du
    Lei Qin
    Zhen-Yu Wang
    Xian-Bing Xu
    Food Analytical Methods, 2018, 11 : 790 - 796
  • [17] Vortex-Assisted Liquid-Liquid Micro-extraction Followed by Head Space Solid Phase Micro-extraction for the Determination of Eugenol in Fish Using GC-MS
    Liang, Xu
    Feng, Ting-Ting
    Wu, Jian-Hai
    Du, Ming
    Qin, Lei
    Wang, Zhen-Yu
    Xu, Xian-Bing
    FOOD ANALYTICAL METHODS, 2018, 11 (03) : 790 - 796
  • [18] An efficient method for the determination of furan derivatives in apple cider and wine by solid phase extraction and high performance liquid chromatography-Diode array detector
    Hu, Gaofei
    Hernandez, Marta
    Zhu, Honghui
    Shao, Suqin
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1284 : 100 - 106
  • [19] Rapid, simple and accurate liquid chromatography-diode array detection validated method for the determination of dipyrone in solid and liquid dosage forms
    Senyuva, HZ
    Aksahin, I
    Ozcan, S
    Kabasakal, BV
    ANALYTICA CHIMICA ACTA, 2005, 547 (01) : 73 - 77
  • [20] Comparison of two different isolation methods of benzimidazoles and their metabolites in the bovine liver by solid-phase extraction and liquid chromatography-diode array detection
    Caprioli, Giovanni
    Cristalli, Gloria
    Galarini, Roberta
    Giacobbe, Dania
    Ricciutelli, Massimo
    Vittori, Sauro
    Zuo, Yanting
    Sagratini, Gianni
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (11) : 1779 - 1785