The Effect of Digital Breast Tomosynthesis Adoption on Facility-Level Breast Cancer Screening Volume

被引:7
|
作者
Lee, Christoph I. [1 ]
Zhu, Weiwei [2 ]
Onega, Tracy L. [3 ]
Germino, Jessica [1 ]
O'Meara, Ellen S. [2 ]
Lehman, Constance D. [4 ]
Henderson, Louise M. [5 ]
Haas, Jennifer S. [6 ]
Kerlikowske, Karla [7 ]
Sprague, Brian L. [8 ]
Rauscher, Garth H. [9 ]
Tosteson, Anna N. A. [3 ]
Alford-Teaster, Jennifer [3 ]
Wernli, Karen J. [2 ]
Miglioretti, Diana L. [10 ]
机构
[1] Univ Washington, Sch Med, Dept Radiol, 825 Eastlake Ave E,G3-200, Seattle, WA 98109 USA
[2] Kaiser Permanente Washington Hlth Res Inst, Seattle, WA USA
[3] Geisel Sch Med, Norris Cotton Canc Ctr, Dartmouth Inst Hlth Policy & Clin Practice, Lebanon, NH USA
[4] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[5] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27515 USA
[6] Harvard Med Sch, Dana Farber Harvard Canc Inst, Harvard Sch Publ Hlth, Brigham & Womens Hosp,Dept Med, Boston, MA USA
[7] Univ Calif San Francisco, Dept Med, San Francisco, CA USA
[8] Univ Vermont, Dept Surg, Burlington, VT 05405 USA
[9] Univ Illinois, Dept Epidemiol, Chicago, IL USA
[10] Univ Calif Davis, Div Biostat, Davis, CA 95616 USA
关键词
breast cancer screening; capacity; digital breast tomosynthesis; technology adoption; MAMMOGRAPHY; AVAILABILITY; DISPARITIES; TECHNOLOGY; SERVICES; ACCESS; TIME;
D O I
10.2214/AJR.17.19350
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine whether digital breast tomosynthesis (DBT) adoption was associated with a decrease in screening mammography capacity across Breast Cancer Screening Consortium facilities, given concerns about increasing imaging and interpretation times associated with DBT. SUBJECTS AND METHODS. Facility characteristics and examination volume data were collected prospectively from Breast Cancer Screening Consortium facilities that adopted DBT between 2011 and 2014. Interrupted time series analyses using Poisson regression models in which facility was considered a random effect were used to evaluate differences between monthly screening volumes during the 12-month preadoption period and the 12-month postadoption period (with the two periods separated by a 3-month lag) and to test for changes in month-to-month facility-level screening volume during the preadoption and postadoption periods. RESULTS. Across five regional breast imaging registries, 15 of 83 facilities (18.1%) adopted DBT for screening between 2011 and 2014. Most had no academic affiliation (73.3% [11/15]), were nonprofit (80.0% [12/15]), and were general radiology practices (66.7% [10/15]). Facility-level monthly screening volumes were slightly higher during the postadoption versus preadoption periods (relative risk [RR], 1.09; 95% CI, 1.06-1.11). Monthly screening volumes remained relatively stable within the preadoption period (RR, 1.00 per month; 95% CI 1.00-1.01 per month) and the postadoption period (RR, 1.00; 95% CI, 1.00-1.01 per month). CONCLUSION. In a cohort of facilities with varied characteristics, monthly screening examination volumes did not decrease after DBT adoption.
引用
收藏
页码:957 / 963
页数:7
相关论文
共 50 条
  • [1] Breast cancer screening with digital breast tomosynthesis
    Skaane, Per
    BREAST CANCER, 2017, 24 (01) : 32 - 41
  • [2] Breast cancer screening with digital breast tomosynthesis
    Per Skaane
    Breast Cancer, 2017, 24 : 32 - 41
  • [3] BREAST TOMOSYNTHESIS OR DIGITAL MAMMOGRAPHY FOR BREAST CANCER SCREENING?
    Svahn, Tony
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 53 - 56
  • [4] Digital breast tomosynthesis in breast cancer screening: an ethical perspective
    Rosenqvist, Simon
    Brannmark, Johan
    Dustler, Magnus
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [5] A new approach to digital breast tomosynthesis for breast cancer screening
    Nishikawa, Robert M.
    Reiser, Ingrid.
    Seifi, Payam
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [6] Breast Cancer Screening with Digital Breast Tomosynthesis Improves Performance of Mammography Screening
    Bae, Min Sun
    Seo, Bo Kyoung
    RADIOLOGY, 2023, 307 (03)
  • [7] Tumor Characteristics and Molecular Subtypes in Breast Cancer Screening with Digital Breast Tomosynthesis: The Malmo Breast Tomosynthesis Screening Trial
    Johnson, Kristin
    Zackrisson, Sophia
    Rosso, Aldana
    Sartor, Hanna
    Saal, Lao H.
    Andersson, Ingvar
    Lang, Kristina
    RADIOLOGY, 2019, 293 (02) : 273 - 281
  • [8] Digital breast tomosynthesis: Potentially a new method for breast cancer screening
    Niklason, LT
    Christian, BT
    Niklason, LE
    Kopans, DB
    Slanetz, PJ
    Castleberry, DE
    Opsahl-Ong, BH
    Landberg, CE
    Giambattista, B
    DIGITAL MAMMOGRAPHY, 1998, 13 : 51 - 56
  • [9] Digital breast tomosynthesis in diagnosis and screening of breast cancer: A systematic review
    Xu, Lu
    Zeng, Baoqi
    Zhan, Siyan
    Sun, Feng
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2020, 29 : 343 - 344
  • [10] Digital Breast Tomosynthesis Screening for Breast Cancer: It Is Cost-effective!
    Slanetz, Priscilla J.
    RADIOLOGY, 2020, 297 (01) : 49 - 50