Microwave Regeneration of Field-Spent Granular Activated Carbon from Power Plants

被引:1
|
作者
Fu, Yi [1 ]
Wang, Luochun [1 ]
Zhou, Zhen [1 ]
机构
[1] Shanghai Univ Elect Power, Shanghai 200090, Peoples R China
关键词
Microwave; Activated carbon; Regeneration; Power plant; THERMAL REGENERATION; GAC; DECOMPOSITION; IRRADIATION;
D O I
10.4028/www.scientific.net/AMR.356-360.2065
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Granular activated carbon (GAC) is extensively used to remove natural organic matter and residential chlorine in water treatment process of power plant. After being used, the spent GAC needs to be regenerated in order to save on operation costs and reduce solid waste disposal. In this study, microwave technique was tried to regenerate the field-spent GAC from a power plant. The effect of microwave power, irradiation time and hydrochloric acid pretreatment were investigated, it was found that microwave could recover the adsorption capacity of GAC within a short time and the tannic acid adsorption efficiency of regenerated GAC was 9 times greater than spent GAC; hydrochloric acid pretreatment could improve the regeneration process, it showed the highest removal efficiency and iodine number, 99.6% and 859 mg/g respectively. The results obtained from SEM-EDX showed that hydrochloric acid pretreatment could remove inorganic matter and other impurities of GAC. All these indicate that microwave technique can effectively regenerate field-spent GAC, and hydrochloric acid pretreatment is an important process before regeneration.
引用
收藏
页码:2065 / 2070
页数:6
相关论文
共 50 条
  • [1] The regeneration of field-spent granular-activated carbons
    San Miguel, G
    Lambert, SD
    Graham, NJD
    WATER RESEARCH, 2001, 35 (11) : 2740 - 2748
  • [2] Valorization of Field-Spent Granular Activated Carbon as Heterogeneous Ozonation Catalyst for Water Treatment
    Lopez-Frances, Anton
    Cabrero-Antonino, Maria
    Bernat-Quesada, Francisco
    Ferrer, Belen
    Blanes, Maria
    Garcia, Rafael
    Almenar, Pura
    Alvaro, Mercedes
    Dhakshinamoorthy, Amarajothi
    Baldovi, Herme G.
    Navalon, Sergio
    CHEMSUSCHEM, 2024, 17 (14)
  • [3] Microwave regeneration of spent powder activated carbon
    Fang, CS
    Lai, PMC
    CHEMICAL ENGINEERING COMMUNICATIONS, 1996, 147 : 17 - 27
  • [4] Microwave regeneration of spent powder activated carbon
    Fang, C.S.
    Lai, Peter M.C.
    Chemical Engineering Communications, 1996, 147 : 17 - 27
  • [5] Investigation of the regeneration of spent activated carbon from water treatment plants
    Idrissi, A. Sghiouri
    Eddine, S. Nour
    Tayoury, M.
    Aqil, M.
    Jacquemin, J.
    Alami, J.
    Ghamouss, F.
    Sehaqui, H.
    Dahbi, M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024, 21 (14) : 8995 - 9006
  • [6] Regeneration of field-spent activated carbon catalysts for low-temperature selective catalytic reduction of NOx with NH3
    Jeon, Jong-Ki
    Kim, Hyeonjoo
    Park, Young-Kwon
    Peden, Charles H. F.
    Kim, Do Heui
    CHEMICAL ENGINEERING JOURNAL, 2011, 174 (01) : 242 - 248
  • [7] Microwave regeneration of granular activated carbon saturated with PFAS
    Gagliano, Erica
    Falciglia, Pietro P.
    Zaker, Yeakub
    Karanfil, Tanju
    Roccaro, Paolo
    WATER RESEARCH, 2021, 198
  • [8] The effect of thermal treatment on the reactivity of field-spent activated carbons
    San Miguel, G
    Lambert, SD
    Graham, NJD
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2003, 40 (03) : 185 - 194
  • [9] Effect of calcium in field-spent GACs on pore development during regeneration
    Cannon, Fred S.
    Snoeyink, Vernon L.
    Lee, Ramon G.
    Dagois, Gerard
    DeWolfe, James R.
    1600, (85):
  • [10] Microwave heating principles and the application to the regeneration of granular activated carbon
    Bradshaw, S.M.
    Van Wyk, E.J.
    De Swardt, J.B.
    Journal of The South African Institute of Mining and Metallurgy, 1998, 98 (04): : 201 - 210